Lubricant Foam Yam ntxwv Tester

Xa kev nug
Lubricant Foam Yam ntxwv Tester
Paub meej
3 thoob ntiaj teb cov qauv, nrog rau daim ntawv pov thawj calibration, cov ntaub ntawv xeem raug
± 0.5℃meej temp tswj, 4-channel parallel test, high efficiency
Ob hom lus kov npo, haum ntau & ib qho kev yuav khoom, 1-xyoo lav tag nrho
Kev faib tawm yam khoom
Cov Khoom Siv Roj Xeem
Share to
Hauj lwm lawm

Khoom Taw Qhia

 

MOEORW-WET71 lubricating oil foam tus yam ntxwv tester yog nruj me ntsis tsim thiab tsim nyob rau hauv raws li Suav teb chaws tus qauv GB/T 12579-2002, thoob ntiaj teb tus qauv ISO 6247, thiab American txuj ASTM D892. Nws raug ntsuas siab & qis kub foaming kev ua haujlwm ntawm lubricants. Cov txheej txheem tiav muaj xws li chav tsev tseem ceeb (24℃qis- da dej kub) thiab auxiliary unit (93.5℃siab{13}}kub da dej) nrog kev tswj xyuas qhov kub thiab txias. Nws txhawb kev sim ib txhij ntawm 4 tus qauv, nruab nrog 5-inch ob hom lus kov npo, tag nrho lub sijhawm tsis siv neeg thiab SSR siab - qhov ntsuas kub tswj qhov ntsuas. Txhua chav tsev raug ntsuas thiab tshuaj xyuas ua ntej xa khoom nrog cov ntaub ntawv calibration. Cov ntaub ntawv xeem uas tsim los ntawm cov cuab yeej no siv tau rau cov ntaub ntawv soj ntsuam zoo. Haum rau cov chaw tsim khoom loj petrochemical, cov tuam txhab roj nplua nyeem, thib peb-cov koom haum xeem thiab cov chaw kuaj hauv tsev kawm ntawv. Peb txhawb nqa qhov project lag luam wholesale, tag nrho - thawv export xaj thiab ib chav tsev muag khoom, pab txhua tus neeg siv khoom nrog ib qho chaw nres nkoj.

 

Tso cai ua raws cai

 

Cov neeg ntsuas no ua raws li 3 lub ntiaj teb lees paub cov roj nplua nyeem ua npuas ncauj kuaj cov qauv. Tag nrho cov khoom siv kho vajtse, lub sijhawm sim, qhov kub thiab txias tsis ua raws li cov qauv txwv. Txhua lub tshuab raug xa nrog cov ntaub ntawv ntsuas ntsuas thiab thib peb - daim ntawv pov thawj kev ntsuas kev sib tw rau kev sib tw, lub Hoobkas tshawb xyuas thiab kev soj ntsuam kev tswj hwm:

  • Suav Yam Yuav Tsum Tau Ua: GB/T 12579-2002 Standard Test Method for Foaming Characteristics of Lubricating Oils. Cov tuam txhab roj nplua nyeem hauv tsev yuav tsum ua raws li tus qauv no; kuaj cov ntaub ntawv los ntawm cov khoom siv uas tsis yog qauv yooj yim tsis muaj kev cai lij choj.
  • International General Standard: ISO 6247 Petroleum Products - Kev txiav txim siab ntawm Foaming yam ntxwv ntawm Lubricating Roj, dav siv rau exported lubricants thiab txawv teb chaws kuaj.
  • American Industrial Standard: ASTM D892 Standard Test Method for Foaming Characteristics of Lubricating Oils, xaiv cov cuab yeej kuaj rau cov tuam txhab petrochemical txawv teb chaws thiab hla - kev tshuaj xyuas cov khoom muag ciam teb. Feem ntau cov nqi qis- cov tshuab ua kom yooj yim tsuas yog simulate cov kev sim uas tsis muaj kev tswj hwm qhov kub thiab txias tsis tu ncua, ua rau muaj kev sib txawv loj heev. Peb tsim -hauv calibration cav cia txuag tag xoom point, txoj kab nqes thiab calibration lub sij hawm cov ntaub ntawv rau tag nrho traceability ntawm ntev -lub sij hawm kuaj huab hwm coj, tshem tawm cov kev pheej hmoo ntawm kev ua raws cai rau manufacturers.

 

Khoom Parameter (Specification)

 

1.Control System

  • Qhov kub thiab txias: 0 ° -99.9 ° C; Standard xeem dual kub zones: 24 ± 0.5 degree, 93.5 ± 0.5 degree
  • Kub qhov tseeb: ± 0.5 ° C. Txais SSR khoom-lub xeev relay contactless kub tswj nrog millisecond fais fab hloov kho kom tshem tawm npuas nyeem ntawv sib txawv los ntawm qhov kub thiab txias. Parallel test nyeem ntawv yuam kev Tsawg dua lossis sib npaug li 5mL.
  • Kev xaiv TP501 rau lub tub yees txias rau qis- chav da dej kub los daws cov teeb meem cua txias thaum ambient kub tshaj 24 degree, sib xws nrog cov chaw sim thoob ntiaj teb nrog rau siab - cheeb tsam kub.

 

2. Cua Flow System

  • 4 ywj siab ntab flowmeters, adjustable ntau yam: 16-160 mL / min; Txheem ntsuas cua ntws: 94mL / min ± 5mL / min
  • Ua tau - hauv cov twj tso kua mis nrog tag nrho cov pa tawm 3L / min, tsis muaj cov cua compressor ntxiv uas yuav tsum tau ua kom txuag tau cov nqi them nyiaj.
  • Standard cua diffuser: 3000-6000mL/min, tiv taus siab 2.45KPa, Hoobkas ua ntej calibrated rau uniform ruaj khov npuas tiam.
  • Ua kom tiav cov cua lim cua: Cua twj tso kua mis → ziab ntauwd (nqus paj rwb + silica gel) → flowmeter → diffuser, cais cov dej vapor thiab impurities kom tsis txhob muaj cov qauv kuaj cuam tshuam.

 

3. Lub Sijhawm Tswjhwm

  • 4-channel ywj pheej pib lub sijhawm, pib hloov ntawm 5min aeration thiab 10min teeb tsa. Lub sij hawm raug ± 1S nrog buzzer tswb tom qab txhua theem xaus.
  • Tsis muaj kev tswj xyuas lub sij hawm yuav tsum tau ua, txhawb kev sim ntsuas kev ua haujlwm rau cov qauv loj los ntawm ntau dua 60%.

 

4.Kev ua haujlwm interface

  • 5-inch LCD kov npo nrog cov ntawv qhia zaub mov tag nrho, ib-nias hloov ntawm Suav & Askiv rau cov chaw tsim khoom hauv tsev thiab xaj xa tawm.
  • Lo lus zais - kaw tsis tau (default: 0000). Tiv thaiv cov neeg ua haujlwm los ntawm kev hloov cov txheej txheem hauv ntau- hloov chaw loj; ib leeg- chav kuaj me me tuaj yeem qhib rau cov kev cai tsis raug.
  • Hauv zos khaws cov ntaub ntawv ntsuas keeb kwm yav dhau los ntev - cov ntaub ntawv tshuaj xyuas thiab xa tawm.

 

5.Basic Hardware Parameters

  • Kev siv hluav taws xob: ± 2300W; Lub hwj chim: AC220V ± 10% 50Hz ± 10%
  • Ib chav nyob qhov ntev: 380mm × 360mm × 770mm, net hnyav 23kg; Tag nrho cov teeb muaj xws li lub ntsiab + pab dual units
  • Kev khiav hauj lwm ib puag ncig: ambient kub 5℃-40 degree, av noo tsawg dua los yog sib npaug rau 80%RH (tsis-condensing), universal rau tag nrho cov xwm txheej hauv chav kuaj.

 

6.Safety Accessories

  • Tag nrho 3-core grounding los tiv thaiv kev tsim tawm; ywj siab fuse tuav ntawm lub hwj chim qhov hluav taws xob nrog cov khoom seem fuse nruab rau txhua lub tshuab rau kev hloov pauv sai.

 

Cov yam ntxwv zoo

 

1. Dual-chamber ywj siab da dej tsim ua rau tib lub sijhawm siab- thiab qis- ntsuas kub
Cov cuab yeej muaj chav da dej tseem ceeb rau qis- ntsuas kub ntawm 24℃thiab ib chav da dej rau siab - ntsuas kub ntawm 93.5℃. Ob txheej ntawm stirring, cua sov, thiab sensing tshuab yog kiag li ywj siab, tshem tawm kub crosstalk; qhov no tso cai rau kev coj ua ib txhij ntawm ob txheej txheem kev sim hauv lub tebchaws ntawm qhov kub thiab txias yam tsis tas yuav tos ib da dej kom sov lossis txias.
Nrog 4 txoj kev sim uas muaj peev xwm ua kom haum rau 4 qhov kev sim ib txhij, ib chav tsev ua tau raws li qhov xav tau ntawm kev sim txhua hnub ntawm 30–50 cov qauv kuaj rau cov qauv me me thiab nruab nrab- cov roj nplua nyeem loj. Kev yuav khoom ntau txo cov naj npawb ntawm cov khoom xav tau, txuag ntawm cov nqi yuav khoom.
 

2. Thickened, corrosion-cov vaj tse tiv taus rau qis qis qis thaum lub sij hawm ntev -, siab - ntim siv
Tag nrho chav tsev nyob yog tsim los ntawm tuab, siab -zoo txias- dov hlau, thaum lub tog raj kheej kawm tiav kev txhawb nqa thiab cov kav dej sab hauv raug kho kom tiv thaiv cov roj paug thiab hnyav corrosion. Txij li cov roj av kuaj ib puag ncig cuam tshuam nrog lub sijhawm ntev ntawm cov kuab tshuaj organic, cov tshuaj tiv thaiv corrosion-cov vaj tse tiv taus txo cov zaus ntawm kev saib xyuas rau siab - cov khoom ntim, txo lub Hoobkas ntev - lub sijhawm ua haujlwm thiab cov nqi tu. Txawm tias siv sij hawm ntev -, cov chav kuaj compact yog resistant rau xeb thiab laus, ua kom lub neej ntev kev pab cuam.
 

3. Modular, cais roj txoj hauv kev kom ntseeg tau tias ib qho -channel tsis ua haujlwm tsis cuam tshuam rau kev ua haujlwm tag nrho
Plaub flowmeter thiab diffusion taub hau txoj kev yog ywj siab kiag li. Yog hais tias ib qho kev tivthaiv hauv ib lub channel tsis ua haujlwm, tsuas yog qhov tshwj xeeb yuav tsum tau hloov pauv, thaum cov channel tseem tuaj yeem sim txuas ntxiv ib txwm. Qhov kev ua txhaum loj no ua kom tsis muaj kev cuam tshuam kev ua haujlwm thaum lub sijhawm loj - ntsuas qhov ntsuas tsis tu ncua- kev ua haujlwm yuav tsis raug tso tseg vim yog ib qho tsis ua haujlwm -thiab txawm tias lub sijhawm ua haujlwm me me- batch sim ntawm ib chav tsev, tsis tas yuav kaw tag nrho lub tshuab rau kev kho.
 

4. Cov txheej txheem tag nrho cov khoom siv; Customizable Options rau ob qho tib si wholesale thiab muag khoom
Standard Hoobkas configuration muaj xws li ib tug 600 mL kawm tiav lub tog raj kheej, roj diffusion taub hau, sealing roj hmab stoppers, desiccant ntau consumables, thiab spare fuses. Kev txiav txim ntau yuav tuaj nrog ib qho khoom plig pub dawb. Cov neeg muag khoom ntawm tus kheej tuaj yeem yuav hnav- thiab- rhuav tshem qhov chaw xws li lub tog raj kheej kawm tiav, diffusion hau, thiab xim- hloov silica gel cais; cov khoom no raug xa mus rau tus kheej, tshem tawm qhov xav tau los yuav cov khoom tiav.

 

Cov yam ntxwv zoo

 

Point 1 |Ua raws li 3 Cov Qauv Ntiaj Teb, Cov Ntawv Tshaj Lij Tshaj Lij Tshaj Lij Tshaj Lij Tshaj Lij GB / T12579, ISO6247, ASTM D892. Factory calibration daim ntawv pov thawj suav nrog. Cov ntaub ntawv xeem dhau kev tswj xyuas kev tswj hwm & cov neeg siv khoom kuaj xyuas lub Hoobkas, tsis muaj kev pheej hmoo ua raws li kev yuav khoom ntau.

 

Point 2 |SSR Siab-Precision Temp Control + Qhuav Cua Circuit Court, Yam tsawg kawg Test yuam kev Contactless SSR kub xauv ntawm ± 0.5℃; ua tiav qhuav lim cua Circuit Court + ua ntej-calibrated diffuser tswj tus qauv aeration txaus. Parallel qauv ua npuas ncauj nyeem sib txawv Tsawg dua lossis sib npaug li 5mL, txiav rov qab- kuaj poob & nqi lab.

 

Point 3 |4-Channel Simultaneous Test, Zoo heev txhim kho Lab Throughput 4 workstations khiav ntawm nws tus kheej nrog dual da dej synchronous ua haujlwm. Kov 4 cov qauv ib zaug, 4x sai dua li qub ib leeg-channel manually timed khoom, tsis xav tau cov tshuab stacked rau kev kuaj loj.

 

Point 4 |Ob hom lus Intelligent Touch System, Fits Factory Standard Management & Ib Leeg Slexible Siv 5-inch ob hom lus kov vaj huam sib luag preloaded nrog cov qauv ntsuas lub sijhawm. Tus password xauv txhawb kev tswj hwm ntau lub Hoobkas ua haujlwm; me me ib qho kev sim qhib dawb rau kev kuaj kev cai, kev ua haujlwm yooj yim nrog tsis muaj kev cob qhia kev cob qhia.

 

Point 5 |Tag Nrho -Lub voj voog Tom qab- Kev Pabcuam Muag Khoom rau Cov Neeg Muag Khoom Muag Khoom Muag Khoom Muag Khoom Muag Khoom Muag Khoom Muag Khoom Muag Khoom Muag Khoom Dawb rau ntawm -qhov chaw teeb tsa, kev cob qhia cov neeg ua haujlwm, kev ntsuas ib xyoos ib zaug thiab cov nqi txo qis. Cov neeg muag khoom lag luam ib leeg tau txais kev qhia ua yeeb yaj kiab hauv thaj chaw deb, 1- xyoo puv tshuab warranty & piece- los ntawm-daim qhov tsis zoo rau qhov xa tawm. Txhua tus neeg siv khoom tau txais kev txhawb nqa kev pabcuam zoo ib yam.

 

Txheem xeem txheej txheem

 

  • Ua ntej-Kev Tu: Ntxuav cov ntsuas lub tog raj kheej ua ntu zus nrog toluene, n-heptane thiab xab npum, yaug nrog dej & acetone ces qhuav tag. Ntxuav cov cua diffusers los ntawm kev kos duab ntau zaus & nias hnyav los ntawm lub taub hau rau tsawg kawg 5 lub voj voog, tshuab ziab kom qhuav nrog cua qhuav.
  • Kev npaj tshuab: Sau cov da dej nrog dej distilled, ua kom qhuav ntauwd nrog cov paj rwb absorbent & xiav silica gel, txuas tag nrho cov hlab cua. Fais fab rau thiab qhib qhov kub thiab txias; teem da dej qis ntawm 24℃thiab da dej siab ntawm 93.5 degree. Nruab TP501 tub yees yog tias chav tsev kub siab tshaj 24 degree.
  • Qauv Preprocessing: Siv 200mL lubricant qauv, kub rau 49℃± 3℃ces txias mus rau 24℃± 3 degree.
  • Kev ntsuas kub qis Theem 1: Muab cov qauv tso rau hauv lub tog raj kheej rau 190mL cim, raus lub tog raj kheej hauv 24℃da dej rau 5min kom txog thaum cov qauv nce mus txog qhov kub thiab txias. Ntxig diffuser, kho flowmeter rau 94mL / min ± 5mL / min. Sau ua npuas ncauj ntim tom qab 5min aeration, sau dua tom qab 10min nyob.
  • Kev Ntsuas Kub Kub Kub: Muab cov qauv tshiab rau 180mL cim, raus lub tog raj kheej hauv 93.5℃da dej kom txog rau thaum qhov kub thiab txias, sau ua npuas ncauj ntim tom qab aeration thiab teeb tsa raws.
  • Tsawg Kub Re-Test Theem: Ua npuas ncauj tom qab ntsuas kub, txias qauv hauv qab 43.5 degree, muab lub tog raj kheej rov qab rau hauv 24℃da dej thiab rov ntsuas kub qis dua.
  • Kev Ua Cov Ntaub Ntawv: Siv cov lej lej nruab nrab ntawm 3 qhov kev xeem sib npaug ua qhov kawg. Txiav lub zog thiab ntxuav tag nrho cov khoom siv tom qab ua tiav.

 

FAQ

 

Q: Koj puas yog cov chaw tsim khoom lossis lub tuam txhab lag luam?

A: Peb yog cov chaw tsim khoom ncaj qha tshwj xeeb hauv siab - cov khoom siv ntsuas hluav taws xob. Peb muaj peb tus kheej R & D pab neeg thiab cov chaw tsim khoom, uas tso cai rau peb muab lub Hoobkas - tus nqi ncaj qha thiab kev tswj xyuas nruj.

Q: Koj qhov warranty thiab tom qab - txoj cai muag khoom yog dab tsi?

A: Txhua chav tuaj nrog 12 lub hlis lav. Tom qab lub warranty tas sij hawm, peb muab kev pab cuam lub neej thiab cov kev pab them nqi kho mob.

Q: Koj puas txhawb kev sib tham lus Askiv?

A: Yog lawm, peb cov qauv qauv muaj cov keyboards Askiv, software, thiab cov neeg siv phau ntawv. Yog tias koj xav tau lwm hom lus, thov hu rau peb los kuaj xyuas qhov muaj rau kev kho.

 

Cim npe nrov: Lubricant ua npuas ncauj yam ntxwv tester, Tuam Tshoj lubricant ua npuas ncauj yam ntxwv tester manufacturers, hoobkas

Xa kev nug