Koj tus kws tshaj lij Transformer Roj BDV Tester Supplier

 

Founded hauv 1992 thiab raug koom ua ke raws li Wuhan Moen Intelligent Electrical Co., Ltd. thaum lub Kaum Ib Hlis 12, 2012, nrog rau npe peev ntawm RMB 36 lab, peb yog lub tuam txhab kev tshaj lij thev naus laus zis tshwj xeeb hauv kev tshawb fawb, kev tsim kho, thiab tsim cov khoom siv hluav taws xob siab -voltage test. Peb qhov chaw 8,000 m² nyob rau hauv Wuhan East Lake High -Tech Development Zone muaj cov kab ntau lawm, R&D cov chaw, thiab cov chaw tswj hwm. Nrog ib pab neeg ua haujlwm paub txog thiab tsim khoom, Moen tsom mus rau cov khoom tseem ceeb xws li kev sim transformers, series resonance systems, thiab lwm yam high -voltage testing equipment. Rov qab los ntawm kev lag luam ntau xyoo, lub tuam txhab tau cog lus rau kev tsim khoom lag luam txhim khu kev qha, kev txhim kho txuas ntxiv, thiab muab cov tswv yim daws teeb meem rau cov khoom siv hluav taws xob thoob ntiaj teb thiab cov neeg siv khoom lag luam.

 

 
 
Vim li cas thiaj xaiv peb
 

Peb Daim Ntawv Pov Thawj
Peb tau ntawv pov thawj hauv ISO 9001 (Quality), ISO 45001 (Kev Noj Qab Haus Huv & Kev Nyab Xeeb), thiab ISO 14001 (Environment), kom ntseeg tau cov qauv siab hauv txhua yam ntawm peb cov haujlwm.

 

Muaj zog R & D muaj peev xwm
Kev cog lus rau kev siv thev naus laus zis, suav nrog kev nqis peev los tsim 750kV reactor daws teeb meem.

 

Kev paub pab neeg
Pab pawg loj hlob ntawm 61 tus neeg ua haujlwm txhawb nqa cov khoom tsim, tsim khoom, thiab kev pabcuam rau cov neeg siv khoom.

 

Ua kom tiav Pre & Tom qab -Kev Pabcuam Muag
Los ntawm kev daws teeb meem tsim thiab kev txhawb nqa rau kev teeb tsa, kev saib xyuas, thiab kev pabcuam nrawm.

 

Insulation Oil Breakdown Voltage (BDV) Tester

 

Rwb thaiv tsev roj tawg Voltage (BDV) Tester

Cov roj hluav taws xob hluav taws xob tawg hluav taws xob, tseem hu ua dielectric zog tester, yog cov cuab yeej tseem ceeb siv los ntsuas qhov zoo thiab kev ua tau zoo ntawm cov roj insulating hauv transformers, Circuit Court breakers, thiab lwm yam khoom siv hluav taws xob siab. Cov neeg ntsuas no txiav txim siab qhov hluav taws xob uas cov roj tsis tuaj yeem tiv thaiv, muab cov ntaub ntawv tseem ceeb rau kev saib xyuas thiab kev nyab xeeb.

 

Output voltage

0 kV-80kV

Boost converter muaj peev xwm

1.5 kVA ua

Voltage boost tus nqi

0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 kV / s (yeem)

Kev ntsuas hluav taws xob yuam kev

±3%

Hwj chim

200W

Tag nrho voltage distortion

<3%

Dimensions & Nyhav

Qhov Loj: 470mm × 425mm × 385mm (L × W × H)

Luj: 40 kg

Lub zog hluav taws xob

AC 220V ± 22V

Fais fab mov zaus

50Hz ± 2.5Hz

Ambient kub

0℃-+40 degree

txheeb ze humidity

<80%

 

Nta ntawm rwb thaiv tsev roj tawg Voltage (BDV) Tester

 

Kev ntsuas hluav taws xob tawg

Lub luag haujlwm tseem ceeb ntawm kev ntsuas roj hluav taws xob yog txhawm rau txiav txim siab qhov hluav taws xob uas cov roj tsis ua hluav taws xob-paub tias qhov hluav taws xob tawg (BDV). Tus nqi no qhia tias cov roj muaj peev xwm tiv taus hluav taws xob tsis muaj arcing.

Kev Ntsuas Lub Sijhawm Ua Haujlwm

Kev ntsuas nrawm sib txawv raws li qib automation, cuam tshuam ncaj qha rau kev saib xyuas kev ua haujlwm thiab kev ua haujlwm poob haujlwm.

Tsis Siv Neeg Voltage Ramping

Cov kws ntsuas qib siab siv cov kev tswj xyuas qhov hluav taws xob kom maj mam ua kom muaj zog hluav taws xob kom txog thaum kev tawg tshwm sim, ua kom muaj kev ntsuas zoo ib yam thiab raug.

Digital Display & Data Management

Niaj hnub nimno rwb thaiv tsev roj testers feature digital interfaces nrog tiag tiag - lub sijhawm saib xyuas thiab cov ntaub ntawv kaw lub peev xwm.

 

Hom Hluav Taws Xob Roj tawg Voltage (BDV) Tester

 
 
01
 

Phau Testers

Yuav tsum muaj tag nrho cov neeg siv kev koom tes hauv kev sim ua tiav, suav nrog kev hloov pauv qhov hluav taws xob thiab kev sau cov txiaj ntsig.

 
02
 

Semi-Cov neeg ntsuas tsis siv neeg

Ua ke kev teeb tsa nrog cov khoom siv hluav taws xob tsis siv neeg hluav taws xob thiab kev ua haujlwm yooj yim.

 
03
 

Fully Automatic Testers

Muab ua tiav automation los ntawm cov qauv thauj khoom mus rau kev soj ntsuam thiab kev tshaj tawm.

 
04
 

Portable vs. Benchtop Models

Muaj nyob rau hauv ob qho tib si portable thiab nyob ruaj ruaj configurations kom haum rau teb thiab lab siv.

Insulation Oil Breakdown Voltage (BDV) Tester

 

Daim ntawv thov ntawm rwb thaiv tsev roj tawg Voltage (BDV) Tester

 

 

Hluav taws xob tsim hluav taws xob thiab kev faib tawm
Cov chaw tsim hluav taws xob, cov chaw xa hluav taws xob, thiab cov chaw xa khoom xa tawm vam khom rau siab -voltage transformers uas muaj roj insulating. Kev ncaj ncees ntawm cov roj no yog qhov tseem ceeb rau kev tiv thaiv luv luv, flashovers, thiab khoom puas tsuaj.

 
 

Kev tsim khoom lag luam
Cov neeg tsim khoom ntawm siab- cov khoom siv hluav taws xob-xws li lub tshuab hluav taws xob, lub cev muaj zog, lub tshuab hloov pauv, thiab HVAC tshuab-Kev ntsuas roj hluav taws xob sib xyaw rau hauv lawv cov txheej txheem kev lees paub zoo. Ua ntej cov cuab yeej tawm ntawm cov kab ntau lawm, cov roj insulating yuav tsum ua tau raws li cov qauv kev ua tau zoo dielectric.

 
 

Kev lag luam roj thiab roj
Offshore platforms, drilling rigs, refineries, thiab petrochemical chaw ua hauj lwm nyob rau hauv hnyav ib puag ncig yam ntxwv los ntawm high humidity, kub hloov, kev co, thiab raug rau corrosive ntsiab - tag nrho cov uas yuav degrade insulating roj nyob rau hauv lub sij hawm.

 
 

Chemical Processing thiab Refining
Cov nroj tsuag tshuaj thiab cov refineries siv loj - nplai hluav taws xob infrastructure rau lub hwj chim reactors, distillation kab, thiab cov txheej txheem tswj systems. Cov cheeb tsam no feem ntau nthuav tawm cov khoom siv hluav taws xob rau cov tshuaj vapors, noo noo, thiab kub heev.

 

 

Cov lus qhia rau kev siv rwb thaiv tsev roj tawg Voltage (BDV) Tester

 

Kev npaj:Thaum npaj lub tester, ib tug yuav tsum xyuas kom meej tias cov electrode sib dhos thiab ntim khoom huv si thiab qhuav. Txhua yam kab mob los yog dej noo tshuav ntawm cov electrodes los yog roj yuav cuam tshuam cov txiaj ntsig ntawm qhov kev sim. Yog tias siv lub ntsuas ntsuas phau ntawv, teeb tsa qhov ntsuas hluav taws xob mus rau qib qis qis ua ntej pib.

 

Oil Sample Collection:Siv lub nkoj huv thiab qhuav xws li lub khob los yog lub thawv yas, sau cov qauv roj transformer thiab cia nws nyob rau ob peb lub sijhawm kom cia cov npuas lossis impurities tam sim no nce mus rau saum npoo. Tom qab ntawd, ncuav cov qauv roj rau hauv lub thawv ntsuas kom zoo, xyuas kom lub thawv ntsuas muaj roj txaus, kwv yees li 2-3 ntiv tes sib sib zog nqus rau electrode submersion.

 

Kev kuaj:Tom qab cov qauv roj tau muab tso rau hauv lub thawv, kaw lub hau kom zoo kom tsis txhob muaj kev sib kis los yog nchuav los ntawm qhov tshwm sim. Yog tias siv lub ntsuas ntsuas phau ntawv, kuj teeb tsa qhov ntsuas hluav taws xob ntxiv kom maj mam.

 

Kev siv hluav taws xob:Maj mam nce qhov voltage los ntawm tig lub pob qhov rooj (rau phau ntawv testers) los yog soj ntsuam (digital testers) raws li qhov voltage yog siv rau cov roj. Saib cov roj kom ze rau txhua qhov kev hloov pauv, xws li lub txim taws, suab nrov, lossis lub teeb ci ntsa iab tam sim ntawd. Qhov no yog hu ua breakdown voltage.

 

Cov ntaub ntawv sau tseg:Hauv Kev tawg, ua tib zoo saib xyuas qhov kev nyeem ntawv voltage thiab txhua yam uas tshwm sim thaum lub sijhawm tawg. Thaum tawg, cov roj siab tsim ib qho teeb meem ntawm electrodes uas ua rau arcing lossis dielectric rupture. Sau qhov voltage no; qhov no yog qhov tawg voltage ntawm cov qauv roj.

 

Cov kev coj ua zoo tshaj plaws rau kev sim ua tau zoo

Ua raws li cov txheej txheem txheem

Ua cov kev ntsuam xyuas raws li cov qauv lees paub xws li IEC 60156 lossis ASTM D877 kom ntseeg tau tias muaj kev sib luag thiab raug nyob thoob plaws kev ntsuas.

 

Siv cov txheej txheem huv huv

Cov qauv tsis huv tuaj yeem ua rau cov ntawv nyeem tsawg tsawg. Ib txwm siv cov ntim ntim qhuav, kaw ntom ntom thiab tsis txhob nthuav tawm cov dej noo los yog cov khoom thaum sau.

Calibrate cov cuab yeej tsis tu ncua

Xyuas kom tus tester yog calibrated ib xyoos ib zaug los yog ib lub chaw tsim tshuaj paus cov txheej txheem los tswj kev ntsuas precision.

Ua ntau yam kev xeem

Siv qhov nruab nrab ntawm rau qhov kev ntsuas ntsuas ib qho piv txwv kom suav tau qhov sib txawv thiab txhim kho qhov kev ntseeg tau.

Kev sib xyaw ua ke nrog Kev Kho Roj

Muab cov kev ntsuam xyuas nrog cov lim dej los yog lub cev qhuav dej kom rov qab ua cov roj zoo thiab txo cov nqi hloov.

 

Kev tu thiab kho
 

Tsis tu ncua Calibration

Ib qho tseem ceeb hauv cov txheej txheem yog kom paub tseeb tias tus tester muab cov txiaj ntsig zoo thaum ua qhov kev xeem. Los ntawm kev ntsuas qhov ntsuas tsis tu ncua, kev nyeem ntawv siab dua lossis qis dua raug zam thaum ua qhov kev ntsuas roj tawg piv rau qhov tseeb. Calibration yog ua raws li cov neeg tsim khoom cov lus qhia. Calibration tuaj yeem ua rau sab hauv lossis sab nraud raws li tus neeg siv khoom ntsuas.

Ntxuav

Tus tester's electrodes yuav tsum tau ntxuav tom qab txhua qhov kev ntsuas hluav taws xob tawg. Qhov no yog vim qhov tsim ntawm cov roj residue, carbon deposits, arcing, thiab lwm yam. Cov deposits ua rau ib tug mus tsis ncaj ncees lawm tshwm sim nyob rau hauv lub tom ntej kev ntsuam xyuas. Siv lint-dawb daim ntaub, txhuam, lossis cov kuab tshuaj tshwj xeeb raws li cov chaw tsim khoom cov lus pom zoo los ntxuav cov electrodes kom huv si.

Kev tshuaj xyuas lub thawv

Xyuas kom meej tias lub thawv ntsuas tsis tawg, puas, lossis muaj kab mob hauv txhua txoj kev. Lub thawv ntim khoom puas tuaj yeem muaj kev phom sij loj lossis cuam tshuam loj rau lub peev xwm muaj roj thaum kuaj. Tshawb xyuas lub thawv ua ntej txhua qhov kev siv, tsom rau nws txoj kev ncaj ncees. Hloov cov thawv uas puas lawm.

Seal thiab Insulation Check

Xyuas cov tester rau txhua yam tsis xws luag hauv cov ntsaws ruaj ruaj lossis insulator, uas tuaj yeem ua rau nkag mus rau cov dej noo lossis kev puas tsuaj ntawm qhov chaw hluav taws xob. Qhov no yuav ua rau rwb thaiv tsev tsis ua haujlwm thiab ua rau muaj kev nyeem ntawv txaus ntshai. Tsis tu ncua xyuas cov ntsaws ruaj ruaj, gaskets, thiab cov ntaub ntawv insulating, thiab hloov lawv thaum hnav tawm. Xyuas kom meej tias tsis muaj degradation ntawm voltage lossis roj raug.

Hloov tshiab software

Hloov kho cov software tsis tu ncua yog tias tus ntsuas ntsuas raws li qhov chaw software los muab kev ua tau zoo tshaj plaws thiab qhov chaw nyob xeem.

 

Daim ntawv pov thawj

 

productcate-400-566
productcate-400-566
productcate-400-566
productcate-400-566

 

FAQ

 

Q: Kuv tuaj yeem xaiv qhov tsim nyog li cas?

A: Nyob zoo cov neeg siv khoom, thov qhia rau peb paub koj cov kev xav tau los ntawm kev xa ntawv lossis online, peb yuav pom zoo kom tsim nyog raws li koj qhov kev thov.

Q: Dab tsi yog qhov kev txiav txim mini?

A: MOQ: feem ntau 1 unit / thooj / teeb

Q: Kuv tuaj yeem them tau li cas?

A: Nyob zoo cov neeg siv khoom, peb lees txais ntau lub sijhawm them nyiaj, xws li T / T, Western Union ...

Q: Puas yuav tawg thaum thauj?

A: Nyob zoo cov neeg siv khoom, thov tsis txhob txhawj, peb ua cov txheej txheem export pob.

Q: Kuv yuav ua li cas yog tias kuv tsis paub yuav siv li cas?

A: Nyob zoo cov neeg siv khoom, thov tsis txhob txhawj xeeb, cov neeg siv phau ntawv yuav raug xa mus ua ke, koj tuaj yeem tiv tauj peb nrog kev txhawb nqa ntau dua. Peb muaj peb khob roj BDV tester too.100kV roj BDV kuj ok.

Raws li ib qho ntawm cov kev tshaj lij transformer roj bdv tester manufacturers hauv Suav teb, peb tau tshwj xeeb los ntawm cov khoom zoo thiab tus nqi zoo. Thov so assured mus yuav cov roj transformer zoo bdv tester hauv Tshuag ntawm no thiab tau txais cov lus hais los ntawm peb lub hoobkas. Customized xaj yog txais tos.

Xa kev nug