Koj tus kws tshaj lij Transformer Load thiab Tsis Muaj Load Loss Tester Supplier
Founded hauv 1992 thiab raug koom ua ke raws li Wuhan Moen Intelligent Electrical Co., Ltd. thaum lub Kaum Ib Hlis 12, 2012, nrog rau npe peev ntawm RMB 36 lab, peb yog lub tuam txhab kev tshaj lij thev naus laus zis tshwj xeeb hauv kev tshawb fawb, kev tsim kho, thiab tsim cov khoom siv hluav taws xob siab -voltage test. Peb qhov chaw 8,000 m² nyob rau hauv Wuhan East Lake High -Tech Development Zone muaj cov kab ntau lawm, R&D cov chaw, thiab cov chaw tswj hwm. Nrog ib pab neeg ua haujlwm paub txog thiab tsim khoom, Moen tsom mus rau cov khoom tseem ceeb xws li kev sim transformers, series resonance systems, thiab lwm yam high -voltage testing equipment. Rov qab los ntawm kev lag luam ntau xyoo, lub tuam txhab tau cog lus rau kev tsim khoom lag luam txhim khu kev qha, kev txhim kho txuas ntxiv, thiab muab cov tswv yim daws teeb meem rau cov khoom siv hluav taws xob thoob ntiaj teb thiab cov neeg siv khoom lag luam.
-
Transformer Peev Xwm, Load & Tsis Tau -Load Loss Tester⚡ 50kVA / 1200V / 30A tso zis (45 ~ 300Hz Variable zaus). 🎯 0.2% Kev ntsuas qhov tseeb (Class 0.2 / 0.5 ib IEC 60076). 🌐 Modbus -TCP Chaw Taws Teeb Tswj (IP20 Rugged Mobile Txee)
-
Transformer Tsis muaj -Load Poob TesterMEBT-WII Smart Tester nta qhov tseeb- xim zaub thiab cov cuab yeej ntse ntsuas ntsuas, ua kom pom tseeb ntawm kev sib haum xeeb ntawm 2nd mus rau 42nd. Nrog muaj zog adaptability nyob rau hauv dav
-
Transformer Capacity & Poob Tester (Tsis muaj-load & Load...MOEORW-WBT43 transformer poob tester rau tsis muaj-load poob. load poob, impedance voltage thiab harmonic ntsuas. Txhawb 3-watt / 2-watt / 1-wattmeter txoj kev nrog sab nraud PT / CT thiab nws pib
-
Transformer Parameter TesterMOEORW-W4300 Transformer Parameter Tester raug ntsuas tsis muaj-load/load tsis thiab 31st- xaj harmonics. Nws txhawb ntau-dimensional auto-calibration, nta yooj yim txuas nrog kev txheeb xyuas qhov
-
Intelligent Transformer Poob Parameter TesterMEBT-WII Intelligent Transformer No-Load/Short-Circuit Loss Tester ntsuas ntau yam transformer tsis suav nrog-load, luv-circuit poob, harmonics, thiab xoom-sequence impedance. Nws nta calibration,
Vim li cas thiaj xaiv peb
Peb Daim Ntawv Pov Thawj
Peb tau ntawv pov thawj hauv ISO 9001 (Quality), ISO 45001 (Kev Noj Qab Haus Huv & Kev Nyab Xeeb), thiab ISO 14001 (Environment), kom ntseeg tau cov qauv siab hauv txhua yam ntawm peb cov haujlwm.
Muaj zog R & D muaj peev xwm
Kev cog lus rau kev siv thev naus laus zis, suav nrog kev nqis peev los tsim 750kV reactor daws teeb meem.
Kev paub pab neeg
Pab pawg loj hlob ntawm 61 tus neeg ua haujlwm txhawb nqa cov khoom tsim, tsim khoom, thiab kev pabcuam rau cov neeg siv khoom.
Ua kom tiav Pre & Tom qab -Kev Pabcuam Muag
Los ntawm kev daws teeb meem tsim thiab kev txhawb nqa rau kev teeb tsa, kev saib xyuas, thiab kev pabcuam nrawm.

Transformer Tsis Muaj Load Losses Test yog ib txoj kev kuaj mob tseem ceeb uas siv los ntsuas lub zog poob uas tshwm sim hauv lub tshuab hloov pauv thaum nws muaj zog tab sis tsis muab cov khoom thauj. Cov kev poob no, feem ntau hu ua hlau poob lossis cov tub ntxhais poob, feem ntau yog tshwm sim los ntawm hysteresis thiab eddy tam sim no hauv cov tub ntxhais sib nqus. Kev ntsuam xyuas tseeb ntawm tsis muaj- load poob pab hauv kev ntsuas kev ua haujlwm ntawm lub tshuab hluav taws xob, kev npaj kho, thiab ua kom muaj kev ua haujlwm zoo.
|
1. Input Specifications |
|
|
Kev ntsuas voltage |
0 ~ 750V dav dav. |
|
Kev ntsuas tam sim no |
0 ~ 20 ~ 100A nrog tsis siv neeg lossis phau ntawv hloov pauv. |
|
2. Qhov tseeb |
|
|
Qhov hluav taws xob |
±0.1% |
|
Tam sim no |
± 0.1% ntawm tag nrho cov nplai |
|
Hwj chim |
± 0.1% (CosΦ > 0.1), ± 0.2% (0.05 < CosΦ < 0.1) |
|
3. Kev ua haujlwm kub |
|
|
Ua haujlwm kub |
-10℃rau +40 degree |
|
4. Fais fab mov |
|
|
Kev Siv Hluav Taws Xob |
AC 160V rau 265V |
|
5. Rwb thaiv tsev |
|
|
(1) Rwb thaiv tsev tsis kam ntawm voltage / tam sim no inputs thiab chassis Ntau dua los yog sib npaug rau 100MΩ. (2) Withstands 2kV (RMS) fais fab zaus voltage ntawm input terminals thiab chassis rau 1 feeb. |
|
|
6. Qhov ntev |
32 x 24 x 13 cm |
|
7. Nyhav |
3kg ua |
Qhov zoo ntawm Transformer No-Load Poob Tester
Kev nyab xeeb
Txo cov kev pheej hmoo cuam tshuam nrog rau siab - cov khoom siv hluav taws xob, tshwj xeeb tshaj yog thaum lub sij hawm sim teb los yog hauv ib puag ncig uas muaj kev txwv kev nyab xeeb.
Kev siv tau
Yuav tsum muaj cov cuab yeej siv tsawg dua thiab tuaj yeem ua tau nrog cov khoom ntsuas nqa tau yooj yim, ua rau nws zoo tagnrho rau ntawm -qhov chaw kuaj mob.
Yooj yim
Kev teeb tsa thiab txhais tau yooj yim dua, yuav tsum muaj kev txawj ntse tsawg dua piv rau tag nrho - nplai siab - cov txheej txheem voltage.
Ceev
Tso cai rau kev soj ntsuam ua ntej sai ntawm kev hloov pauv kev noj qab haus huv yam tsis muaj kev siv zog tag nrho.
Hom Transformer No-Load Poob Tester
Kev khiav hauj lwm ntawm ib qho -theem transformer tester yog ncaj nraim, raws li nws sim lub transformer siv ib theem xwb. Nws ntsuas ob qho tib si load thiab tsis muaj -load poob los ntawm ib lub hwj chim mov. Ua portable, xws li testers yog zoo tagnrho rau cov hauj lwm ceev. Lawv qhov yooj yim ua rau lawv haum rau me me -scale transformers.
Ib tug peb -theem transformer tester ua cov kev xeem ntawm tag nrho peb theem ib txhij. Cov ntsuas no yog siv los txheeb xyuas qhov nyuaj, peb -theem transformers kom huv si kom pom qhov poob. Lawv muab ib daim duab tiav ntawm transformer efficiency los ntawm kev ntsuas tsis muaj -load thiab load poob tib lub sijhawm.
Cov neeg sim no sib xyaw ua ke ntau lub luag haujlwm, tham txog kev ntsuas tsis muaj -load poob, load poob, thiab ntau ntxiv rau hauv ib qho. Cov neeg ntsuas ntse yog qhov txawv los ntawm kev nyeem ntawv digital thiab muaj peev xwm khaws cov ntaub ntawv. Cov cuab yeej tshiab no txhim kho kev ua haujlwm tau zoo los ntawm kev ua haujlwm hauv chaw taws teeb, uas yog qhov zoo tshaj plaws rau kev siv hauv thaj chaw.
Cov khoom siv txawb tau hais los saum toj no yog tsim los rau kev siv teb thiab khaws cov kev sim tseem ceeb hauv daim ntawv cog lus. Cov ntsuas no ntsuas qhov hnyav thiab tsis muaj- thauj khoom poob thaum lub teeb thiab nqa tau yooj yim. Lawv qhov yooj yim txhais tau hais tias kev kuaj mob tuaj yeem ua tau tiag tiag - lub sijhawm yam tsis tau txav lub tshuab hloov pauv ntawm nws qhov chaw.
Transformers uas ua qhov kev sim yuav pab tshem tawm tib neeg kev ua yuam kev los ntawm automating txheej txheem xeem. Hais tias, cov neeg ntsuas no tuaj yeem ntsuas tsis muaj - thauj khoom thiab thauj khoom poob ib txhij thaum khaws cov ntaub ntawv sai thiab raug.
Daim ntawv thov ntawm Transformer No-Load Loss Tester
Fais Fab Tsim thiab faib tuam txhab uas muag
Kev ntsuam xyuas transformers hauv cov chaw nres tsheb fais fab thiab cov chaw nres tsheb nrog lub thauj khoom thiab tsis muaj -load poob tester xyuas kom meej tias txhua qhov transformers ua tau raws li qhov xav tau. Qhov kev coj ua no pab cov lag luam hluav taws xob zam kom tsis txhob muaj hluav taws xob hluav taws xob los ntawm kev hloov pauv tsis zoo. Cov neeg ntsuas no feem ntau tau yuav hauv cov ntim loj los ntawm cov tuam txhab siv hluav taws xob.
Transformer Manufacturing Facilities
Chaw tsim tshuaj paus siv cov testers kom paub meej tias tag nrho cov transformers ua tau raws li cov qauv zoo ua ntej muag. Cov txiaj ntsig kuaj xyuas pab cov tuam txhab txheeb xyuas cov khoom tsis zoo lossis cov khoom tsis raug kom lawv tsis raug muag rau cov neeg siv khoom. Cov chaw tsim khoom loj kuj xav tau ntau tus neeg sim ua kom tiav kev sim sai.
Cov nroj tsuag muaj
Cov chaw tsim khoom loj, cov nroj tsuag petrochemical, thiab lwm yam kev lag luam uas xav tau kev nqis peev hluav taws xob siv cov ntsuas no. Industries xyuas kom meej tias transformers nyob rau hauv lawv cov hluav taws xob systems yog npaum thiab tuav ntev -lub sij hawm los ntawm kev sim lawv raws sij hawm.
Kho thiab kho tuam txhab uas muag
Thib peb-cov tuam txhab tu vaj tse uas kho lossis kev pabcuam hluav taws xob hauv cov tsev lag luam kuj siv tus ntsuas no. Cov neeg kuaj xyuas pab cov neeg ua haujlwm saib xyuas pom cov khoom siv tsis zoo kom lawv tuaj yeem hloov lossis kho lawv ua ntej ua rau muaj kev puas tsuaj ntau dua. Kho cov lag luam yuav cov neeg sim no hauv ntau thiab khaws cia siv raws li qhov xav tau lossis hauv kev tshwj xeeb.
Cov chaw zov me nyuam
Cov ntaub ntawv loj loj nrog kev siv hluav taws xob siab tso siab rau cov ntsuas no los tswj lawv cov transformers thiab tsis txhob overload. Poob testers pom cov transformers tsis muaj txiaj ntsig hauv cov chaw khaws ntaub ntawv yog li cov hloov pauv tau nruab ua ntej lawv ua rau poob qis.
HVAC Co
Muaj ntau lub tshuab cua sov, qhov cua, thiab cua txias hauv cov tsev lag luam uas suav nrog cov tshuab hluav taws xob. HVAC cov lag luam siv transformer testers los xyuas kom meej tias tag nrho cov Cheebtsam ua hauj lwm los txhim kho system efficiency.
Kev Npaj Kev Nyab Xeeb
Xyuas kom lub transformer yog de{0}}energized, grounded, thiab cais. Paub meej tias txhua tus neeg ua haujlwm ua raws li cov txheej txheem kaw / tagout (LOTO) thiab siv cov cuab yeej tiv thaiv tus kheej tsim nyog (PPE).
Kuaj teeb
Txuas lub precision wattmeter, voltmeter, thiab ammeter mus rau thawj winding. Cia lub thib ob winding qhib. Siv qhov sib txawv AC qhov chaw los siv qhov ntsuas hluav taws xob maj mam.
Kev txais cov ntaub ntawv
Sau qhov voltage, tam sim no, lub zog, thiab zaus ntawm lub xeev khov kho. Ntau qhov kev nyeem ntawv tuaj yeem raug coj los ua kom raug thiab suav rau kev ntsuas ntsuas.
Kev xam poob
Xam tsis muaj-load poob uas siv cov nqi ntsuas. Sib piv cov txiaj ntsig nrog cov ntaub ntawv sau npe lossis cov ntaub ntawv kuaj xyuas lub Hoobkas txhawm rau txheeb xyuas qhov tsis txaus ntseeg.
Kev Qhia thiab Kev Ntsuam Xyuas
Tsim ib daim ntawv qhia ntxaws nrog rau cov kev xeem, cov cuab yeej siv, cov txiaj ntsig tau pom, thiab sib piv nrog cov ntaub ntawv hauv paus. suav nrog cov lus pom zoo rau kev tshawb nrhiav ntxiv yog tias poob siab tshaj qhov kev lees paub (feem ntau ± 10% ntawm tus nqi ntsuas).
Method of Testing of Transformer No-Load Loss Teste
Tsawg-Voltage Excitation Method
Ib qho kev nyab xeeb thiab feem ntau siv txoj hauv kev uas qhov txo qis yog siv rau qhov qis -voltage (LV) winding thaum lub siab -voltage (HV) winding qhib. Txoj kev no txo qis kev pheej hmoo thiab yog qhov zoo tshaj plaws rau kev sim teb. Txawm hais tias qhov tseeb me ntsis vim qhov ntsuas qhov ntsuas, cov cuab yeej niaj hnub no raug rau qhov tsis yog -linearities, ua rau nws ua haujlwm zoo rau kev ntsuas niaj hnub.
High -Voltage Excitation Method
Yuav tsum siv tag nrho cov ntsuas hluav taws xob rau HV winding. Qhov no muab qhov tseeb tshaj plaws sawv cev ntawm cov kev ua haujlwm tiag tiag thiab feem ntau yog siv rau hauv kev kuaj pom zoo (FATs). Txawm li cas los xij, nws yuav tsum tau tshwj xeeb siab - cov cuab yeej hluav taws xob thiab cov txheej txheem kev nyab xeeb nruj, ua rau nws tsis tshua muaj txiaj ntsig rau ntawm - siv qhov chaw.
Residual Voltage Method
Siv tau thaum tsuas yog ib qho winding nkag tau. Nws ntsuas induced voltage nyob rau hauv qhib winding rau infer core poob indirectly. Thaum yooj yim, txoj kev no tsis tshua muaj tseeb thiab yuav tsum tau siv tsuas yog thaum cov txheej txheem tsis ua tau.
Txoj Kev Choj (xws li Schering Choj)
Feem ntau siv rau kev ntsuas dielectric poob thiab capacitance tab sis tuaj yeem pab txhawb kev poob qis hauv kev sib txuas nrog lwm cov tswv yim. Cov no yog cov tshwj xeeb tshaj plaws thiab feem ntau yog ib feem ntawm kev txheeb xyuas kev rwb thaiv tsev.
Daim ntawv pov thawj




FAQ
Raws li ib qho ntawm cov kev tshaj lij transformer load thiab tsis muaj load poob tester tuam ntxhab nyob rau hauv Suav teb, peb nyob nraum featured los ntawm cov khoom zoo thiab tus nqi zoo. Thov so assured mus yuav high quality transformer load thiab tsis muaj load poob tester nyob rau hauv Tshuag ntawm no thiab tau txais cov lus hais los ntawm peb lub hoobkas. Customized xaj yog txais tos.