Insulated GC analyzers
MOEORW-WEP75 yog cov roj chromatograph tshwj xeeb tsim los rau cov roj hloov pauv, ua kom pom tseeb ntawm cov roj yaj hauv cov roj insulating.
EPC / EPC muaj cov pa roj qhov ntsuas kub tswj, kev sib raug zoo nrog ntau lub tshuab ntes, tswj cov chaw taws teeb Ethernet, thiab ruaj khov thiab ua haujlwm tau zoo.
Nws yog qhov tsim nyog rau kev txheeb xyuas cov khoom siv hauv ntau qhov chaw xws li lub zog, petrochemical, kev saib xyuas ib puag ncig, kev tswj hwm kev lag luam thiab cov chaw soj ntsuam kev tshawb fawb.
Khoom Taw Qhia
Gas chromatography yog ib qho txheej txheem rau kev sib cais thiab tshuaj xyuas ntau yam -cov khoom sib xyaw. Nws tsuas yog siv qhov sib txawv ntawm qhov kub thiab txias, polarity, thiab adsorption coefficient ntawm cov khoom hauv ib qho qauv hauv chromatographic kem cais cov khoom thiab ua qhov zoo thiab qhov kev soj ntsuam ntau ntawm cov khoom sib cais.
Transformer roj tsom xam roj chromatographs siv roj raws li theem mobile (carrier gas). Thaum cov qauv pub rau hauv cov tshuaj txhaj tshuaj thiab vaporized, nws yog nqa los ntawm cov cab kuj roj mus rau hauv ib kem los yog capillary kem. Vim qhov sib txawv ntawm qhov kub ntawm qhov kub, qhov polarity, thiab adsorption coefficient ntawm txhua yam hauv cov qauv, cov khoom sib cais nyob rau hauv kem. Tom qab ntawd, lub ntsuas ntsuas txuas nrog rau kab pom txhua qhov sib xyaw ua ke raws li nws cov khoom siv physicochemical. Thaum kawg, cov ntaub ntawv raug xa mus rau chromatography workstation ntawm network. Lub chromatography workstation cov ntaub ntawv thiab tshuaj xyuas cov roj chromatograms ntawm txhua feem kom tau txais ib daim ntawv ntsuam xyuas.
Khoom Parameter (Specification)
● Kev ua haujlwm zaub: 7-inch high-definition capacitive touchscreen
●Kub tswj cheeb tsam: 8 raws
● Kev tswj qhov kub thiab txias: 3℃siab dua chav tsev kub txog 450 degree, nce ntxiv: 0.1 degree, qhov tseeb: ± 0.01 degree
● Tus naj npawb ntawm qhov kub thiab txias -ups: 99
● Cov cua kub siab tshaj plaws: 120℃/ min
● Gas Circuit Court tswj: Siab hluav taws xob thiab ntws tswj
● Carrier gas tswj hom: siab, ntws tus nqi, linear tshaj tawm, programmed siab, programmed flow rate, programmed linear tshaj tawm
●Program stress/flow rate/linear velocity: 12th order
● Kev ntsuas ntau: Siab: 0-0.6Mpa, Flow rate: 0-100mL/min lossis 0-1000mL/min
● Kev daws teeb meem: 0.001psi
● Sab nrauv txheej xwm: 8 raws; Pab tswj cov zis: 2 raws
● Hom injectors : packed kem injector, capillary injector, rau -way valve gas injector, autosampler
●Ntau tus ntes: 4 (ntau tshaj); FID, TCD, ECD, FPD, NPD, PDHID, PED, thiab lwm yam.
● Kev txhaj tshuaj pib: phau ntawv los yog tsis siv neeg xaiv tau
● Kev Sib Txuas Lus: Ethernet: IEEE 802.3
1.3.2 Ntes Technical Specifications
1. Nplaim Ionization Detector (FID)
● Kev kuaj pom qhov txwv: Tsawg dua lossis sib npaug li 1 ×10⁻¹² g/s (hexadecane/isooctane)
● Lub suab nrov: Tsawg dua lossis sib npaug li 2 ×10⁻¹⁴ A
● Baseline drift: Tsawg dua lossis sib npaug li 1 ×10⁻¹³ A/30 min
● Linear range: Ntau dua lossis sib npaug rau 107
2. Thermal conductivity ntes (TCD)
●Sensitivity: S Ntau dua los yog sib npaug rau 10000mV•ml/mg (benzene/toluene) (nrog xaiv tau amplification ntawm 1, 2, 3, los yog 4 zaug)
● Lub suab nrov: Tsawg dua lossis sib npaug li 20μV
● Baseline drift: Tsawg dua lossis sib npaug li 30μV / 30min
● Linear ntau:Ntau dua lossis sib npaug li 10⁵
3. Electron Capture Detector (ECD)
● Kev kuaj pom qhov txwv: Tsawg dua lossis sib npaug rau 1 ×10⁻¹⁴ g/ml (gamma{0}}hexane- isooctane kua)
● Lub suab nrov: Tsawg dua lossis sib npaug ntawm 0.03mV
● Baseline drift: Tsawg dua lossis sib npaug li 0.2mV / 30min
● Linear ntau:10⁵
● Radioactive qhov chaw: 63Ni
4. Flame Photometric Ntes (FPD)
● Kev kuaj pom qhov txwv: (S) Tsawg dua lossis sib npaug ntawm 2 × 10⁻¹¹g /s
(P) Tsawg dua lossis sib npaug li 1 × 10⁻¹²g /s; (methyl parathion -anhydrous ethanol kua)
● Lub suab nrov: Tsawg dua lossis sib npaug li 3 ×10⁻¹³ A
● Baseline drift: Tsawg dua lossis sib npaug li 2 ×10⁻¹² A/30 min
● Linear range: Ntau dua lossis sib npaug li 10³ rau leej faj, Ntau dua lossis sib npaug li 10⁴rau phosphorus
5. Nitrogen-Phosphorus Detector (NPD)
● Kev ntsuas qhov txwv: (N) Tsawg dua lossis sib npaug li 1 ×10⁻¹² g/s; (Azobenzene)
(P) Tsawg dua lossis sib npaug li 1 × 10⁻¹²g /s; (malathion)
● Lub suab nrov: Tsawg dua lossis sib npaug li 5 ×10⁻¹³ A
● Baseline drift: Tsawg dua lossis sib npaug li 2 ×10⁻¹² A/30 min
● Linear range: Ntau dua lossis sib npaug rau 103
Khoom nta thiab kev siv
★ Nws txais kev sib txuas lus siab tshaj 100Mbps/Gigabit Ethernet interfaces thiab muaj ib qho ua tau -nyob rau hauv IP raws tu qauv pawg, ua kom cov twj paj nruag ua tau ntev - cov ntaub ntawv kis tau tus mob los ntawm kev lag luam sab hauv LAN thiab Is Taws Nem; Nws ua kom yooj yim rau kev teeb tsa hauv chav kuaj, ua kom yooj yim rau kev sim teeb tsa, thiab ua kom yooj yim rau kev tswj xyuas cov ntaub ntawv txheeb xyuas;
★ Cov cuab yeej tau nruab nrog lub chaw ua haujlwm tshwj xeeb uas tuaj yeem pab txhawb kev sib txuas ib txhij ntawm ntau cov chromatographs, ua kom cov ntaub ntawv ua thiab rov qab tswj cov twj paj nruag, thiab ua kom yooj yim rau kev tswj cov ntaub ntawv;
★ Lub ntsuas hluav taws xob tuaj yeem txuas mus rau cov chaw tsim khoom hauv Is Taws Nem txhawm rau txhawm rau kuaj cov chaw taws teeb, hloov kho tej thaj chaw deb, thiab lwm yam. (cov neeg siv yuav tsum tau teeb tsa);
★ Cov zaub yog 7 -inch high-txhais capacitive touchscreen ;
★ Cov cuab yeej siv ntau -processor ua haujlwm sib luag hom, ua kom ruaj khov thiab txhim khu kev qha; nws tuaj yeem nruab nrog ntau yam ntawm -cov cuab yeej ua tau zoo, xws li FID, TCD, ECD, FPD thiab NPD, thiab txog li plaub lub cuab yeej tuaj yeem ntsia tau rau tib lub sijhawm kom ua tau raws li qhov xav tau ntawm kev soj ntsuam cov qauv nyuaj.
★ Cov cuab yeej siv cov qauv tsim qauv, ua rau kev txij nkawm yooj yim thiab yooj yim.
★ Lub hom phiaj - tshiab microcomputer kub tswj system muaj qhov kub thiab txias tswj qhov tseeb, kev ntseeg tau zoo heev thiab tiv thaiv- cuam tshuam kev ua haujlwm; nws muaj yim qhov kev tswj xyuas qhov kub thiab txias, tuaj yeem paub txog cuaj caum- cuaj- theem programmable kub nce, muaj qhov tsis siv neeg lub qhov rooj qhib qhov rooj rau kab kem, txhim kho nyob ze ntawm chav ntsuas kub, thiab muaj cua sov / cua txias ceev;
★ Lub ntsuas hluav taws xob tau nruab nrog cov khoom siv hluav taws xob siab tshaj plaws (EFC) thiab hluav taws xob tswj lub siab (EPC) kom paub txog kev tswj hwm digital ntawm cov pa roj, uas ua rau muaj txiaj ntsig zoo ntawm qhov ntsuas thiab qhov rov ua dua ntawm cov txiaj ntsig kev soj ntsuam;
★ Lub chromatograph muaj ib qho ua tau - nyob rau hauv qis- suab nrov, siab - daws teeb meem 24-ntsis AD Circuit Court thiab nta lub hauv paus cia thiab lub hauv paus rho tawm haujlwm.
★ Tus qauv chaw ua haujlwm tau sib xws nrog cov haujlwm ua haujlwm xws li WinXP, Win2000, Win7, Win8, thiab Win10.
★ Lub kaw lus chromatograph microcomputer nrog kev ywj pheej ntawm kev txawj ntse muaj cai muaj tus qauv MODBUS / TCP raws tu qauv thiab tuaj yeem txuas nrog DCS system.
Kev tsim tawm cov ntsiab lus
√ Kev kuaj xyuas cov roj yaj thiab cov yam ntxwv txhaum cai hauv cov roj transformerhauv kev lag luam fais fabpab txheeb xyuas latent faults nyob rau hauv transformers thiab ua kom muaj kev ruaj ntseg ntawm cov khoom siv fais fab.
√ Petrochemicalroj tivthaiv tsom xam, kev tsim cov txheej txheem zoo xyuas, thiab cov khoom siv raw thiab cov khoom tiav purity kuaj.
√ Kev tsom xam ntawm cov organic tebchaw tsis hloov pauv thiab organophosphorus / sulfur pollutants hauv dej thiab avrau kev saib xyuas ib puag ncig.
√ Tshawb xyuas cov tshuaj tua kab thiab cov kuab tshuaj nyob hauvkhoom noj thiab tshuaj; purity tsom xam ntawm kws tshuaj intermediates thiab raw khoom.
√ Kev tswj xyuas zoo thiab kev tshawb fawb txog kev lag luam:Kev tshuaj xyuas zoo ntawm cov khoom siv tshuaj, kev tshawb fawb hauv chav kuaj, thiab kev soj ntsuam online ntawm cov txheej txheem ntau lawm.
Lub Tuam Txhab Txuj Ci
Q: Koj puas yog lub Hoobkas lossis tuam txhab lag luam?
Peb yog cov chaw tsim khoom ntawm cov khoom siv kuaj.
Q: Cov kev pab cuam tom qab muag zoo li cas?
A: Lub sijhawm lav yog 12 lub hlis. Tom qab lub sij hawm warranty, peb kuj muab kev pab them nqi kho mob los yog kev pab cuam lub neej.
Q: Cov kev pab cuam tom qab muag zoo li cas?
A: Lub sijhawm lav yog 12 lub hlis. Tom qab lub sij hawm warranty, peb kuj muab kev pab them nqi kho mob los yog kev pab cuam lub neej.
Q: Yuav ua li cas txog kev thauj mus los?
A: Nws nyob ntawm koj qhov kev xav tau. Peb tuaj yeem xa tuaj rau koj lub tshav dav hlau los ntawm huab cua, mus rau koj qhov chaw nres nkoj los ntawm hiav txwv, lossis rau koj lub chaw ua haujlwm los ntawm courier.
Peb kuj lees txais kev koom tes nrog koj tus neeg sawv cev shipping.
Q: Puas yog koj cov keyboard, interface, software, thiab phau ntawv txhais lus Askiv?
A: Yog, yog tias koj siv cov lus Askiv version ntawm cov keyboard, interface, software, thiab phau ntawv thiab xav tau lwm hom lus, thov hu rau peb kom paub meej.
Cim npe nrov: Tuam Tshoj Insulated Gc Analyzers Manufacturers thiab lwm tus neeg - Tuam Tshoj Insulated Gc Analyzer