MOEORW-WE301 Tsis Siv Neeg Huab Cua Tso Tawm Tus Nqi Tester rau Lubricating Roj, tseem hu ua Air Release Tester, Air Release Test Apparatus, SH/T0308 Air Release Analyzer, Oil Foam Air Separation Detector, Turbine Oil Air Release Testing Equipment in the lag luam. Lub tshuab tag nrho yog tsim thiab tsim nyob rau hauv nruj raws li SH/T 0308-92 Standard Test Method for Air Release Value of Lubricating Oil, tshwj xeeb uas tsim los ntsuam xyuas cov npuas cua tso tawm kev ua tau zoo ntawm hydraulic roj, turbine roj thiab ntau yam roj av khoom. Nws yog dav siv nyob rau hauv fais fab nroj tsuag, roj av refineries, tshuaj manufacturers, thib peb-tog roj kuaj kuaj, tsim machinery zoo soj ntsuam departments thiab tsev kawm ntawv lub zog tshuaj labs. Nws tuaj yeem sau tau lub sijhawm xav tau rau cov npuas ntim hauv cov qauv roj kom txo qis rau 0.2%. Tag nrho cov ntaub ntawv xeem ua raws li lub teb chaws tus qauv thiab tuaj yeem siv rau CNAS lub chaw kuaj xyuas kev lees paub.
Siv tau Standard & Test Principple
Siv tau Standard
Tag nrho cov cuab yeej siv tshuab, ntsuas qhov kub thiab txias, roj hluav taws xob hluav taws xob thiab lub sijhawm ua haujlwm siab ua raws li SH/T 0308-92 Standard Test Method rau Cua Tshaj Tawm Tus Nqi ntawm Lubricating Roj; tag nrho cov txheej txheem xeem thiab cov kev txwv tsis pub dhau yog ua raws li lub teb chaws tus qauv specifications.
Test Principple
Tshav kub cov qauv roj rau cov qauv ntsuas kub ntawm 25℃/ 50℃/ 70 degree, pub compressed cua nyob rau tib qhov kub thiab txias rau tag nrho agitation los ua npuas npuas npuas hauv cov roj. Tom qab tso tseg huab cua, txiav txim qhov seem npuas ntim los ntawm qhov sib txawv ntawm qhov sib txawv thiab sau lub sijhawm thaum npuas huab cua ntim poob rau 0.2%, uas txhais tau tias yog roj cua tso tawm tus nqi. Cov kev xeem logic tiav yog solidified nyob rau hauv qhov kev pab cuam ntawm huab cua tso tester yam tsis muaj phau ntawv hloov dua siab tshiab.
Khoom Parameter (Specification)
|
Dej Da Dej Kub Kub Ntau Yam |
Ambient ~ 99.9 degree, Temp Control Tsawg dua los yog sib npaug rau ± 1 degree |
|
Cua Da Dej Kub Ntau Yam |
Ambient ~ 90.0 degree, Temp Control Tsawg dua lossis sib npaug li ± 5 degree |
|
Lub sij hawm raug |
± 1s rau kev ntes cov sij hawm sib cais tseem ceeb |
|
Zaub |
5.0-nti 480 × 272 xim kov LCD, tag nrho suav ua haujlwm interface |
|
Siv Dej Da Dej Volume |
5L |
|
Max zog |
Tsawg dua lossis sib npaug li 1000W |
|
Fais fab mov |
AC220V ± 22V 50Hz |
|
Zuag qhia tag nrho Dimension |
560mm × 350mm × 490mm |
|
Net nyhav |
23kg ua |
|
Kev khiav hauj lwm ib puag ncig Humidity |
Tsawg dua lossis sib npaug li 85% (tsis yog-condensing) Ua- hauv kev kho cov coefficients rau da dej thiab chav da dej kub kom ntsuas qhov sib txawv los ntawm qhov sib txawv ntawm qhov kub thiab txias. Txhua qhov tsis siv neeg tso cua tso tawm tus nqi ntsuas yog xa nrog cov ntaub ntawv ua tiav lub Hoobkas ua kom tiav rau qhov ntsuas tsis tau. |
Kho vajtse Configuration
- Gas Circuit Assembly: Nruab nrog roj- lub twj tso kua mis tsis muaj suab nrov tom qab 72h tsis tu ncua tsis muaj-load aging test rau huab cua ruaj khov. General G1/4 xov cua inlet matched nrog φ10 PU raj, φ9 / φ12 txheem latex raj, universal consumables tau tshaj tag nrho cov huab cua tso tawm test apparatus qauv. Siab -precision siab ntsuas & adjustable siab regulator tuav tus qauv cua siab ntawm 0.02MPa stably.
- Dual Independent Temperature Control: Dual -channel microcomputer cais tswj cov dej da dej thiab chav da dej tsis muaj kev cuam tshuam, ua kom muaj cua sov sai dua & qhov kub thiab txias ua haujlwm, cov khoom siv tseem ceeb ntawm SH/T0308 cua tso tawm analyzer.
- Intelligent Water Bath System: Tiag tiag -lub sij hawm ua kua theem kuaj pom & ib qho - qhov tseem ceeb pib dej ntxiv. Acoustic & lub tswb ceeb toom nrog cua sov txiav- tawm hauv qab dej tsis txaus los tiv thaiv kom qhuav kub. Tsuas yog cov dej huv huv, dej demineralized lossis dej ultrapure tsuas yog tso cai rau dej ntxiv.
- Kov Tswj System: Tag Nrho Suav pom kev pom lub vijtsam sib xyaw ua ke nrog lub moos calibration, dual timers, cov tswv yim ceev, sib cais lub sijhawm, dej ntxiv, qhov chaw teeb tsa, cov ntaub ntawv khaws cia thiab luam ntawv txuas ntxiv; kev khiav hauj lwm interface tag nrho matched nrog daim duab phau ntawv.
- Qauv los ua ke: Standard jacketed iav xeem raj nrog φ12 txheem txuas raj, anti- plam puag. Standardized spare qhov chaw txhawb bulk cais procurement.
- Kev Tiv Thaiv Kev Nyab Xeeb: 3-core grounded fais fab mov nrog fuse ywj siab rau overload & luv-circuit tiv thaiv. Gas Circuit Court overpressure nyem qauv zam lub raj rupture nyob rau hauv siab.
Core Functions
Dual Timing Function Timer 1 & Timer 2 nrog lub Hoobkas teeb tsa ntawm 5min thiab 7min, kho tau dawb hauv cov ntawv qhia zaub mov. Timer 1 rau compressed cua preheating, Timer 2 rau roj aeration agitation. Nws pib acoustic & lub teeb ceeb toom thaum countdown tiav yam tsis muaj phau ntawv saib.
Dual Independent Temp Control Dej da dej & da dej cua tuaj yeem hloov mus rau / tawm cais nrog qhov ntsuas kub hloov tau ua ntej. Ua-nyob rau hauv kev kho qhov kub thiab txias muaj nuj nqi calibrates sib txawv ntawm tus pas ntsuas kub tus qauv thaum hloov chaw ua hauj lwm los yog raws caij nyoog kub hloov pauv, kom ntseeg tau ntev- lub sij hawm ntsuam xyuas qhov tseeb ntawm npuas huab cua sib cais detector.
Density Input & Auto Separation Timing Manual input oil density within 0.6000~1.2000g/cm³; ib qho - qhov tseem ceeb pib sib cais lub sij hawm tom qab cua txiav - tawm. Nres lub sij hawm manually thaum qhov ceev poob mus rau d1=d0-0.0017 (0.2% npuas ntim) los sau cov nqi tso tawm zaum kawg. Kev txiav txim siab ua raws li SH/T 0308-92: Thawj cov roj ntom ntom d0, lub hom phiaj ntom ntom d1=d0-0.0017 sib haum rau 0.2% seem cua ntim, ua haujlwm raws li lub sijhawm teem sijhawm nres tus qauv yam tsis muaj phau ntawv npuas cov ntaub ntawv txiav txim siab tsis pub dawb.
Auto Water Replenishment Protection 3-xim kua theem qhia: Liab=dej tsis txaus (nws pib dej puv los ntawm ib nias); flashing ntsuab=theem dej nruab nrab; ruaj khov ntsuab=dej puv nrog nws pib twj tso kua mis nres, tsis muaj dej txaus.
Data Storage & Traceability Local auto storage of full test data including oil density, bubble separation time, test time and equipment calibration records, supporting page flip & single record deletion. Printing muaj nuj nqi yog customized yeem; serial luam ntawv module tuaj yeem ntsia tau raws li kev txiav txim kom xa daim ntawv xeem ntawv rau kev kuaj ua ntaub ntawv.
Cov Khoom Siv Calibration Function Ua tau-hauv da dej & cua da dej kub kho cov ntawv qhia zaub mov nrog ua ntej-calibrated da dej P/I coefficients thiab cua da dej PID tsis nyob rau hauv lub hoobkas. Tsuas yog cov neeg ua haujlwm tshaj lij tuaj yeem kho qhov ntsuas qhov ntsuas kub kom tsis txhob muaj qhov tseeb tshwm sim los ntawm kev ua haujlwm tsis raug ntawm huab cua tso tawm tester.
Core Zoo
Tag Nrho Cov Qauv Ua Raws Li Lub Tebchaws & Cov Ntawv Pov Thawj Kev Xeem
Tag nrho cov khoom kho vajtse & software ua raws li SH/T 0308-92, qhov kub thiab txias, lub sij hawm thiab lub siab yuam kev zoo tshaj li tus qauv txwv. Txhua qhov tsis siv neeg cua tso tawm tester yog xa nrog lub Hoobkas calibration daim ntawv pov thawj; cov ntaub ntawv xeem tau lees paub rau kev tshawb xyuas kev tsim nyog ntawm cov chaw kuaj thib peb, cov chaw tsim hluav taws xob thiab cov tuam txhab petrochemical nrog kev sib raug zoo.
Kub re-calibration txhua 6 lub hlis raws li kev ua haujlwm ib txwm raug pom zoo. Standard mercury thermometer calibration rau da dej da dej & da dej cua yog yuav tsum tau tom qab lub caij hloov los yog chaw soj nstuam tsiv chaw kom tswj tau raws li cov ntaub ntawv xeem.
Cov txheej txheem tsis siv neeg ua haujlwm txo qis kev tuav haujlwm nyuaj
Txhim kho tag nrho cov txheej txheem kev sim hauv lub tebchaws nrog nws pib dej ntxiv, ceeb toom lub sijhawm, ib qho - lub sijhawm tseem ceeb thiab nws pib khaws cov ntaub ntawv. Tag nrho Suav kov npo sib phim nrog cov duab piav qhia ua rau tus neeg teb xov tooj tuaj yeem paub qhov ntsuas cua tso tawm sai sai thiab txiav phau ntawv yuam kev.
Modular Universal Spare Parts rau Qis Ntev -Tsev Them Nqi Kho
Kev lag luam tus qauv raj, connectors thiab iav xeem raj nrog txaus Tshuag ntawm hnav qhov chaw. Tsuas yog faulty module hloov yuav tsum tau rau kev saib xyuas es tsis txhob ntawm tag nrho cov tshuab rov qab. Cov khoom siv dav dav ntawm cov khoom siv tau qis dua ntev dua - lub sijhawm ua haujlwm tus nqi ntawm SH/T0308 cua tso tawm analyzer.
Ntau- txheej Kev Tiv Thaiv Kev Nyab Xeeb rau Kev Ua Haujlwm ruaj khov & Ua haujlwm ntev
Nruab nrog kev tiv thaiv kev kub hnyiab nyob rau hauv dej tsis txaus, kev tiv thaiv hauv av, kev tiv thaiv overload fuse thiab roj overpressure nyem. 23kg hnyav ruaj khov lub cev nrog tiv thaiv-slip test tube puag tshem tawm qhov kev pheej hmoo ntawm kev nyab xeeb thaum lub sij hawm ntev - teev tas mus li, zoo tagnrho rau siab -ntau zaus kuaj.
Multi-function Ib Chav Ua Haujlwm Npog Txhua Hom Roj
Ib lub tshuab ua npuas dej sib cais ua tiav qhov kev ntsuas cua tso tawm rau cov roj hydraulic, roj turbine thiab tag nrho cov khoom siv roj. Ib lub tshuab ua tau raws li tag nrho cov kev ntsuas kev ntsuas uas yuav tsum tau ua kom txuag tau nyiaj txiag thiab lub rooj zaum qhov chaw tsis muaj ntau yam khoom siv.
Standard Accessories List
- MOEORW-WE301 Main Unit × 1
- Jacketed iav Test Tube × 1 Teeb
- Ua tiav txheej ntawm φ10 PU raj, φ9 / φ12 latex txuas raj
- Siab Txo Valve Sib Tsoo, PTFE daim kab xev
- Fais fab Cord, Spare Fuse
- Daim Ntawv Qhia Kev Ua Haujlwm
- Factory Equipment Calibration Record Sheet Yeem Cov Khoom Siv Khoom Siv: Cov iav tsom iav tsom iav, sealing gasket, hloov cov raj, lim haum, bulk bundled muas txaus siab.
FAQ
Q: Koj puas yog cov chaw tsim khoom lossis lub tuam txhab lag luam?
A: Peb yog cov chaw tsim khoom ncaj qha tshwj xeeb hauv siab - cov khoom siv ntsuas hluav taws xob. Peb muaj peb tus kheej R & D pab neeg thiab cov chaw tsim khoom, uas tso cai rau peb muab lub Hoobkas - tus nqi ncaj qha thiab kev tswj xyuas nruj.
Q: Koj qhov warranty thiab tom qab - txoj cai muag khoom yog dab tsi?
A: Txhua chav tuaj nrog 12 lub hlis lav. Tom qab lub warranty tas sij hawm, peb muab kev pab cuam lub neej thiab cov kev pab them nqi kho mob.
Q: Koj puas txhawb kev sib tham lus Askiv?
A: Yog lawm, peb cov qauv qauv muaj cov keyboards Askiv, software, thiab cov neeg siv phau ntawv. Yog tias koj xav tau lwm hom lus, thov hu rau peb los kuaj xyuas qhov muaj rau kev kho.
Cim npe nrov: Tuam Tshoj tsis siv neeg cua tso tus nqi tester rau lubricating roj, Tuam Tshoj tsis siv neeg cua tso tus nqi tester rau lubricating roj manufacturers, hoobkas