Autoignition Point Tester Rau Hluav Taws Kub Resistant Roj

Xa kev nug
Autoignition Point Tester Rau Hluav Taws Kub Resistant Roj
Paub meej
Tsawg dua lossis sib npaug li 1℃Peb-Point Temp Difference, Cov Ntawv Qhia Ua Raws Cai
40 Batches Txhua Hnub Batch Test, Ntawm -Site Calibration Tsis Muaj Kev Xa Rov Qab
4-Txheej Txheej Kev Nyab Xeeb Kev Nyab Xeeb, Ib-Stop Instrument & Consumable Supply
Kev faib tawm yam khoom
Cov Khoom Siv Roj Xeem
Share to
Hauj lwm lawm

Khoom Taw Qhia

 

MOEORW-WER31 Autoignition Point Tester rau Cov Hluav Taws Xob Hluav Taws Xob yog tsim los ntawm nruj raws li kev lag luam hluav taws xob hluav taws xob tus qauv DL/T 706-}1999 Kev Ntsuas Tus Txheej Txheem rau Autoignition Point of Fire Resistant Fluid Siv hauv Cov Hluav Taws Xob Hluav Taws Xob, thiab sib xws nrog DL/T 571 Specification rau Hluav Taws Xob Roj Roj Test Nws yog cov cuab yeej tshwj xeeb rau kev ntsuas qhov ntsuas kub ntawm phosphate ester hluav taws kub resistant roj siv nyob rau hauv kev tswj ceev ntawm cov generating units saum toj no 30MW. Tag nrho cov ntaub ntawv xeem uas tsim tawm tuaj yeem lees paub los ntawm lub tuam tsev saib xyuas kev nyab xeeb ntawm lub tuam tsev hluav taws xob thiab CMA thib peb -chaw kuaj sim. Nruab nrog tus kheej -tsim AI ntse tswj qhov kub thiab txias algorithm, cov cuab yeej ua tiav tag nrho cov thermal tshuav nyiaj li cas nyob rau sab saum toj, nruab nrab thiab hauv qab ntawm lub rhaub dej kub, nrog qhov kub sib txawv ntawm peb lub ntsiab lus tswj hauv 1℃. Ib qho kev sib xyaw ua ke yog nruab rau kev pom cov nplaim taws. Featuring ruaj khov kev ua tau zoo thiab kev ua haujlwm yooj yim, nws ua haujlwm pab pawg tsim hluav taws xob, lub koom haum tshawb fawb hluav taws xob hluav taws xob, cov tuam txhab roj nplua nyeem, thib peb- cov chaw kuaj roj thiab cov tuam txhab kev lag luam thiab kev saib xyuas. Nws txhawb nqa kev sib tw ntau rau cov pab pawg loj thiab kev yuav khoom ib leeg rau cov tuam txhab kho me me thiab cov chaw tsim hluav taws xob ywj pheej.

 

Khoom Parameter (Specification)

 

Tib neeg -Machine Interaction

4-nti muaj xim kov npo nrog ceev kub hloov khawm ntawm ± 2℃/ ± 5℃/ ± 10 degree, zoo heev txhim kho efficiency ntawm batch gradient kuaj

Kub Tswj System

Txais AI ntse ntsuas kub tswj algorithm. Kev tswj qhov kub thiab txias: 75℃~ 800 degree, kev daws teeb meem kub: 0.1 degree, tag nrho qhov kub thiab txias tswj qhov tseeb: ± 1 degree, qhov kub sib txawv ntawm sab saum toj / nruab nrab / hauv qab hauv lub raj mis tsawg dua lossis sib npaug li 1 degree. Cov cuab yeej zoo sib xws ntawm kev ua lag luam feem ntau muaj 3 ~ 5℃qhov kub thiab txias sib txawv, uas yuav ua rau autoignition test deviation tshaj 20 degree. Cov ntaub ntawv rov ua yuam kev ntawm peb cov neeg ntsuas tsawg dua 0.5%, thiab tag nrho cov txiaj ntsig tau raug lees paub.

Kub ntsuas Cheebtsam

K- hom kev lag luam kub resistant thermocouple, tsis kub drift nyob rau hauv ntev - lub sij hawm ua hauj lwm tas mus li ntawm 800 degree, txo nqi consumable nqi ntawm sensor hloov

Fais fab Parameter

Rated zog 1800W, ceev cua sov ceev, muaj peev xwm ntawm kev sim ntau tshaj 40 batch ntawm cov qauv ib hnub twg

Kev ua haujlwm ib puag ncig

Ambient kub 5℃~ 40 degree, txheeb ze av noo tsawg dua los yog sib npaug rau 80% RH. Nws khiav ruaj khov nyob rau hauv cov chaw ua haujlwm sab qab teb, qis-kub sab qaum teb kev cob qhia thiab tas li- chav ntsuas kub.

Dimension & Nyhav

Zuag qhia tag nrho loj 531mm × 435mm × 385mm, hnyav txog 30kg. Standard Laboratory lub rooj ntev zaum loj, ruaj khov qhov chaw tsis muaj chaw reconstruction.

Standard Accessories

200mL tshav kub-resistant conical flask, 0.01mL micro quantitative syringe, soj ntsuam reflector raws li tus qauv configuration. Tag nrho cov khoom hnav yog muaj rau cov khoom siv los ntawm peb lub hoobkas.

 

Standard Working Principple & Test Procedure

 

Cov cuab yeej siv AI puv -ntau qhov ntsuas kub tswj algorithm kom tswj tau qhov thermal tshuav hauv 200mL qhib conical flask. Kos 0.05mL hluav taws kub resistant roj coj mus kuaj thiab txhaj tshuaj sai rau hauv lub hwj nyob rau hauv preset kub nrog siab -precision micro syringe, ces pib 1-feeb sij hawm:
1.Yog nplaim taws tshwm nyob rau hauv 1 feeb, qhov kub thiab txias tam sim no yog autoignition point ntawm cov qauv roj;
2.Yog tias tsis muaj nplaim taws tshwm sim, nce qhov kub ntawm 10℃rau kev rov kuaj dua, nrog lub sijhawm tsawg kawg 15 feeb ntawm ob qhov kev sim;
3.Yog pom nplaim taws, qhov kub thiab txias los ntawm 5℃ib kauj ruam thiab rov sim dua kom txog thaum tsis muaj autoignition tshwm sim. Sau qhov tsawg kawg nkaus ignition kub raws li autoignition point ntawm roj. Tag nrho cov txheej txheem xeem ua raws li DL / T 706 tus qauv kev lag luam. Unified standardized operation logic tshem tawm cov ntaub ntawv sib txawv los ntawm cov neeg ua haujlwm sib txawv, kom ntseeg tau tias cov ntaub ntawv xeem zoo ib yam thiab ruaj khov rau cov qauv loj, uas ua tau raws li qhov xav tau ntawm kev tshuaj xyuas roj txhua hli ntawm thib peb - cov chaw sim thiab cov chaw tsim hluav taws xob.

 

Cov haujlwm tseem ceeb

 

Independent Temperature Calibration & Kho

Ntev nias "Sample Test" ntawm lub vijtsam kov kom nkag mus rau qhov kub thiab txias pib- nplooj ntawv tuning. Qhov ntsuas kub ntawm sab saum toj, nruab nrab thiab hauv qab tuaj yeem kho nyias. Calibration tuaj yeem ua tiav ntawm qhov chaw nrog ib nias tom qab cov khoom laus lossis cov khoom hloov pauv yam tsis muaj lub Hoobkas rov qab los, txo qis heev tom qab- muag cov nqi muag khoom.
 

Quick Gradient Temperature Control Vaj Huam Sib Luag

Ib qho -nias qhov kub hloov pauv ntawm ± 2 / ± 5 / ± 10℃yam tsis muaj phau ntawv nkag, txo qis kev ua haujlwm rov ua haujlwm rau ntau- ntsuas kub ntsuas, zoo tagnrho rau kev sim loj ntawm kev lag luam thib peb- tog tsev.
 

Tib -Tus Neeg Saib Xyuas Kev Pom Zoo

Dedicated reflector kev koom ua ke ntawm lub cub tawg sab saum toj yam tsis muaj cov cuab yeej saib xyuas ntxiv. Ib tus neeg soj ntsuam tuaj yeem ua tiav kev txhaj tshuaj, lub sijhawm thiab kev soj ntsuam nplaim taws ntawm nws tus kheej kom txiav nqi zog.
 

Modular Flask Hloov Structure

Sensor bracket nrog txwv kev tsheb ciav hlau swb thiab siab - qhov ntsuas kub ntsuas qhov tsim los tiv thaiv kev sib tsoo los ntawm qhov yuam kev. Flask tuaj yeem hloov tau hauv 3 kauj ruam tom qab txias hauv 5 feeb los ntawm ib tus neeg teb xov tooj yam tsis muaj ncua sij hawm ntsuas huab hwm coj.

 

Ull -Range Safety Protection Design

 

Standard 3-Wire Safe Power Supply:Matches industrial socket with live wire L, neutral wire N thiab tiv thaiv lub ntiaj teb E. Cov khoom siv yuav tsum muaj kev ntseeg siab hauv av kom tsis txhob muaj hluav taws xob los ntawm qhov kub ntawm - qhov kub ntawm cov roj hluav taws xob ntsuas kub, dhau kev soj ntsuam kev nyab xeeb ntawm lub tuam tsev saib xyuas hluav taws xob.

 

Split Loj -Qhov Chaw Thaum tshav kub kub Dissipation Air Duct:Independent tshav kub dissipation grilles ntawm sab vaj huam sib luag, tsis muaj overheating tom qab 8- teev tas mus li qhov ntsuas huab hwm coj, tshem tawm cov kev pheej hmoo ntawm kub kub scald thiab ib puag ncig roj ignition.

 

Mechanical High -Tsub Limiting Protection:Kub sensor nrog limiting cover slide rail qauv, flask tsis tau disassembled nyob rau hauv siab kub kom lub cev tsis txhob scald xwm txheej.

 

Kev tiv thaiv Circuit Court Overload:Ua tau - nyob rau hauv kev tiv thaiv overload tiv thaiv kev tsis sib haum thaum ntau yam twj paj nruag ua haujlwm nyob rau hauv tib lub chaw kuaj. Txhua qhov kev saib xyuas yuav tsum tau ua los ntawm cov kws tshaj lij kws tshaj lij tom qab txiav hluav taws xob. Ua- nyob rau hauv kev sib cais tsim hluav taws xob txo kev tiv thaiv kev nyab xeeb.

 

Khoom feature

 

1: Sab saum toj-Tier Uniform Temperature Control, Compliant Test Reports lees txais los ntawm CMA & Kev Saib Xyuas Kev Tswj Hluav Taws Xob
Tsim los ntawm DL/T 706-1999 tus qauv nrog tus kheej-tsim AI puv-ntau qhov ntsuas kub tswj algorithm, qhov kub ntawm qhov sib txawv ntawm lub raj mis sab saum toj, nruab nrab thiab hauv qab yog nruj me ntsis txwv tsis pub dhau 1℃. Cov cuab yeej sib tw zoo ib yam muaj 3 ~ 5℃qhov kub sib txawv uas ua rau autoignition xeem yuam kev tshaj 20℃thiab cov ntawv ceeb toom tsis raug lees paub los ntawm cov nroj tsuag fais fab thiab thib peb- cov chaw sim. Qhov ntsuas no ua tiav ± 1℃qhov kub thiab txias tswj qhov tseeb thiab 0.1℃qhov ntsuas kub nrog cov ntaub ntawv rov ua yuam kev tsawg dua 0.5% rau cov qauv loj. Txhua chav tsev tau dhau 8-teev qhov ntsuas kub ntawm kev laus thiab ntsuas peb-point kub ua ntej xa khoom. Cov ntaub ntawv xeem tau raug lees paub, ua rau nws yog qhov yuav tsum tau ntsuas rau kev sib tw cog hluav taws xob thiab kuaj cov ntawv pov thawj tsim nyog.
 

2: Tus Nqi & Lub Sijhawm Txuag rau Kev Xeem Batch, Zoo meej rau B-Xaum Kev Tshawb Fawb Kev Tshawb Fawb
Nruab nrog 1800W siab- lub zog cua sov thiab 4-inch industrial kov npo nrog ib qho- nyem ± 2/5/10℃gradient hloov khawm yam tsis muaj phau ntawv nkag. Integrated furnace reflector enables ib tug -tus neeg ua hauj lwm tag nrho nrog rau kev txhaj tshuaj, lub sij hawm thiab kev soj ntsuam nplaim taws yam tsis muaj zog ntxiv. Lub sijhawm ntsuas rau ib pawg yog txiav los ntawm 30%, txhawb nqa ntau dua 40 tus qauv ua haujlwm ib hnub. Ntawm -site ib qho-nias qhov kub thiab txias pib-tu thiab cais peb- taw qhia kev kho kom tsis txhob muaj lub Hoobkas rov qab thiab cov khoom siv poob qis, txo qis zog thiab lub sijhawm ua haujlwm nqi rau cov chaw thib peb thiab cov chaw tsim hluav taws xob loj.

 

3: Tag Nrho Kev Lag Luam -Qib Kev Nyab Xeeb + Ib -Tshuag Khoom & Tom Qab- Kev Muag Khoom, Tsawg Ntev -Lub Sij Hawm Nruab Nrab Cov Nqi Them Nqi Kho

  • Kev Nyab Xeeb Kev Nyab Xeeb: Plaub- txheej tiv thaiv nrog rau tus qauv 3- hlau hauv av, ywj siab tshav kub dissipation duct, mechanical siab - qhov ntsuas kub ntsuas qhov ntsuas thiab tiv thaiv Circuit Court overload tiv thaiv, ntsib kev nyab xeeb kev soj ntsuam cov qauv ntawm kev pheej hmoo hluav taws xob ntsuas qhov xwm txheej thiab zam kev raug kaw los ntawm hluav taws xob to, hluav taws kub thiab hluav taws xob.
  • Supply Strength: Thawj cov chaw tsim khoom nws tus kheej- tsim tag nrho cov twj paj nruag thiab tag nrho cov khoom siv sib xws nrog rau cov raj mis conical, K-hom thermocouples thiab micro syringes. Tiered luv nqi rau kev txiav txim ntau thiab ntev - daim ntawv cog lus khoom siv tau muaj.
  • Tom qab-Kev Txhawb Kev Muag Khoom: National 400 qhov kev pabcuam xovtooj kub thiab hauv cheeb tsam ntawm -tus kws tshaj lij. Txuas ntxiv warranty rau cov khoom tseem ceeb tuaj yeem sib tham rau cov neeg yuav khoom ntau. Nyob ze tom qab- kev muag khoom rau ntau- pab pawg neeg siv khoom thiab ib qho - ntawm - ib qho kev taw qhia kev ua haujlwm nyob deb rau ib leeg - cov neeg yuav khoom, suav nrog txhua hom neeg siv khoom.

 

FAQ

 

Q: Koj puas yog cov chaw tsim khoom lossis lub tuam txhab lag luam?

A: Peb yog cov chaw tsim khoom ncaj qha tshwj xeeb hauv siab - cov khoom siv ntsuas hluav taws xob. Peb muaj peb tus kheej R & D pab neeg thiab cov chaw tsim khoom, uas tso cai rau peb muab lub Hoobkas - tus nqi ncaj qha thiab kev tswj xyuas nruj.

Q: Koj qhov warranty thiab tom qab - txoj cai muag khoom yog dab tsi?

A: Txhua chav tuaj nrog 12 lub hlis lav. Tom qab lub warranty tas sij hawm, peb muab kev pab cuam lub neej thiab cov kev pab them nqi kho mob.

Q: Koj puas txhawb kev sib tham lus Askiv?

A: Yog lawm, peb cov qauv qauv muaj cov keyboards Askiv, software, thiab cov neeg siv phau ntawv. Yog tias koj xav tau lwm hom lus, thov hu rau peb los kuaj xyuas qhov muaj rau kev kho.

 

Cim npe nrov: Tuam Tshoj autoignition point tester rau hluav taws kub resistant roj, Tuam Tshoj autoignition point tester rau hluav taws kub resistant roj manufacturers, hoobkas

Xa kev nug