Active Transformer Peev Xwm thiab Cov yam ntxwv Tester

Xa kev nug
Active Transformer Peev Xwm thiab Cov yam ntxwv Tester
Paub meej
MOEORW-WBT67 Active Transformer Capacity and Characteristic Tester — portable and precise.Auto- txheeb xyuas cov xaim, hloov ntau yam, calibrates nrog ntau yam algorithms.320 × 240 HD touchscreen, preset parameters, fais fab {{6}tawm cov ntaub ntawv khaws cia.
Kev faib tawm yam khoom
Transformer Test Set
Share to
Hauj lwm lawm

Active Transformer Peev Xwm Thiab Cov yam ntxwv Tester

 

Khoom Taw Qhia

 

Lub siab -cov cuab yeej tuav tes ua tau zoo rau ntawm- kev txheeb xyuas qhov chaw ntawm kev faib khoom- lub peev xwm hloov pauv, tsis muaj - thauj khoom & thauj khoom (luv-circuit) poob, impedance voltage thiab lub zog- ntsuas kev ua tau zoo - rau ob qho tib si -theem thiab peb theem{{8} transformers. Ua-nyob rau hauv lub hwj chim qhov chaw txhais tau tias tsis muaj lwm yam voltage regulator los yog boosting transformer yuav tsum tau.

 

Vim li cas "Active"? - Ua-hauv Qhov Chaw, Tiag Ntawm -site Portability

Tsis zoo li passive testers uas yuav tsum tau noj los ntawm ib tug sab nraud regulating transformer thiab hnyav boosting khoom, lub MOEORW-WBT67 yog ib tug active tester nrog ib tug integrated peb-phase AC qhov chaw thiab rechargeable roj teeb. Cov neeg ua haujlwm hauv teb tuaj yeem ua qhov muaj peev xwm thiab qhov kev xeem poob ncaj qha ntawm lub tshuab hloov pauv - hauv lub chaw nres tsheb, ntawm tus ncej-mounted unit, lossis hauv chav tsev faib khoom lag luam - yam tsis tau nqa lub zog sab nraud.


Tsim los tiv thaiv hluav taws xob dag. Raws li Tuam Tshoj ob- tus nqi se, cov neeg siv them tus nqi pib los ntawm kev tshaj tawm lub peev xwm hloov pauv. Qee qhov tsis raug cai pauv cov npe lossis nce - tus nqi kom them tsawg dua. Lub MOEORW-WBT67 yog lub hom phiaj- tsim rau kev tshuaj xyuas hluav taws xob & daim ntawv teev npe- pov thawj muaj peev xwm - nws ntsuas qhov muaj peev xwm thiab qhov poob, nthuav tawm tampered lossis tshaj- ntsuas cov transformers. Zoo tagnrho rau cov khoom siv hluav taws xob, cov chaw tsim hluav taws xob transformer thiab tiv thaiv- pab pawg tshuaj xyuas tub sab.

 

Khoom Parameter (Specification)

 

1. Cov xwm txheej ib puag ncig

Kub

-5℃rau 40 degree

txheeb ze humidity

<95% (at 25°C)

Qhov siab

<2500m

Sab nraud cuam tshuam

Tsis muaj kev vibration heev, tsis muaj zog electromagnetic teb

Sab nraud fais fab mov

220VAC ± 10%, 45Hz txog 55Hz

2. Kev ntsuas qhov ntsuas

Cov khoom xyaw nquag

 

Cov zis tam sim no

0 rau 10a

Kev ntsuas hluav taws xob

0–10V

Test Peev Xwm

 

10kV Roj-immersed/Dry- hom Transformers

30kVA – 2500kVA

35kV Roj-immersed Transformers

50kVA – 31500kVA

20kV Qhuav- hom Transformers

50kVA – 2500kVA

35kV Qhuav-Hom Transformers

50kVA rau 2000kVA

Cov yam ntxwv seem

Qhov hluav taws xob

0 txog 600V, tsis siv neeg sab hauv ntau hloov pauv

Tam sim no

0 txog 100A, tsis siv neeg sab hauv hloov pauv

Ntau zaus

45Hz txog 65Hz

3. Kuaj qhov tseeb

Qhov hluav taws xob

2-100V, ± 0.2% FS; 100-450V, ± 0.2%

Tam sim no

0.5-10A, ± 0.2% FS; 10-100A, ± 0.2%

Hwj chim

± 0.5% (CosΦ > 0.1), ± 1.0% (0.02 < CosΦ < 0.1)

4. Rwb thaiv tsev muaj zog

Rwb thaiv tsev tsis kam ntawm voltage / tam sim no input terminals thiab chassis Ntau dua los yog sib npaug rau 100MΩ.

Withstands 2kV (RMS) fais fab zaus voltage ntawm lub hwj chim input terminals thiab chassis rau 1 feeb.

5. Lwm yam Specifications

 

Qhov ntev

400 × 300 × 170 hli

Qhov hnyav

6kg (tsis suav nrog kev xeem ua)

 

Cov yam ntxwv tseem ceeb

 

  • Qhov tseeb ntsuas lub peev xwm ntawm ntau yam kev faib transformers - yooj yim thiab meej.
  • Ntsuas lub peev xwm, lub zog-kev ntsuas kev ua tau zoo, hom, tsis muaj-load tam sim no, tsis muaj-load poob, luv-circuit (load) voltage thiab luv-circuit (load) poob hauv ib chav.
  • Sab hauv nws pib ntau yam -hloov hla qhov dav voltage/tam sim no ntau yam nrog cov xaim yooj yim.
  • Thaum tsis muaj -load thiab load xeem ntawm peb-theem transformers, lub ntsuasauto- txheeb xyuas qhov raug xaimthiab qhia peb -theem voltage / tam sim no vector daim duab (dual-/three-wattmeter method, internally pre-wired).
  • Ib chav tsev ua haujlwm puv - tam sim no load tests rau faib transformersqis dua 1000 kVA; ntawm ib - thib peb rated tam sim no nws npog unitsqis dua 3150 kVAthiab xam qhov ntsuas -tam sim no load poob cia li.
  • Tag nrho cov txiaj ntsig tau pib- kho: waveform, kub, tsis yog- ntsuas qhov hluav taws xob thiab tsis yog- ntsuas tam sim no kho - kom raug siab dua. Ob qhov kub thiab txias - kho algorithms (coefficient method & national- qauv formula).
  • 320 × 240 siab- brightness LCD nrog tag nrho cov ntawv qhia zaub mov thiab kev ua haujlwm sai (Lus Askiv / Suav xaiv tau), kov cov yuam sij, dav - kub LCD nrog kev hloov qhov ci.
  • Mus txog40 preset specimen parameter sets, ntxiv / rho tawm raws li xav tau.
  • Ua-hauv tiag- lub sijhawm moos pib- teev hnub xeem & sijhawm.
  • Vaj huam sib luag thermal tshuab luam ntawv rau instant ntawm -site printout (suav nrog txiav txim siab zog- qib efficiency).
  • Fais fab-tawm cov ntaub ntawv khaws cia & xauj raumus txog 500 cov ntaub ntawv xeem; txuas rau lub PC rau cov ntaub ntawv xa tawm ntawm kev sib txuas lus chaw nres nkoj + USB.
  • Sab nraud voltage / tam sim no transformers tuaj yeem txuas ntxiv qhov ntsuas qhov ntsuas kom npog txhua qhov ntsuas ntawm qhov ntsuas khoom.

 

 

Daim ntawv thov Scenario

Kev tshuaj xyuas hluav taws xob & kev kuaj xyuas muaj peev xwm

Tshawb xyuas daim ntawv teev npe tampering thiab tsis raug cai nce - ntsuas; txheeb xyuas qhov muaj peev xwm tshaj tawm tiag tiag kom raug - them nqi.

Factory txais kev xeem

Xyuas kom tsis muaj -load/load poob, impedance voltage thiab efficiency ntsuam xyuas ua ntej lub transformer ships los yog commissioned.

Kev tu ncua & kev xa mus

Lub sijhawm kuaj xyuas cov khoom siv hluav taws xob, cov chaw tsim khoom siv hluav taws xob thiab cov chaw faib khoom lag luam.

Hauv -qhov chaw kuaj mob

Substations, ncej-mounted units thiab indoor room - tsis muaj lwm regulator yuav tsum tau ua tsaug rau cov built- hauv qhov chaw.

 

Txheem & Transformer Compatibility

 

Muaj peev xwm & hom kev xeem lub hom phiaj lub teb chaws -tus qauv faib transformers nrog 400 V AC qis-voltage sab (peb-theem). Cov cuab yeej txhawb nqa hom series:

Roj- hom kev raus dej

S(H) 7/9/11/13/14/15 series.

01

Qhuav -type (SCB) hom

SCB9 / 10 / 11 / 12 ntawm 100 degree, 120℃thiab 145℃rwb thaiv tsev chav kawm.

02

Tib-theem & peb-phase

Ob leeg winding configurations txhawb; kev sib txuas- hom pab pawg yog xaiv tau.

03

Siv hom tso zis

Cov ntawv ceeb toom txiav txim siab muaj peev xwm, ntsuas qhov peev xwm, lub teb chaws - tus qauv poob, kho qhov poob, impedance voltage thiab siv hom.

04

Ua -hauv Roj Teeb & Them

 

Cov twj tso kua mis xa nrog lub roj teeb ua ntej - qhib tau rov qab. Rau kev ua tau zoo tshaj plaws:

  • Xyuas cov roj teeb theem ua ntej siv; yog tias muaj kev ceeb toom hnyav nyob rau hauv -voltage ceeb toom tshwm, nres thiab rov them sai sai - roj teeb kev puas tsuaj los ntawm kev siv qis qis yuav tsis them los ntawm kev lav dawb.
  • Charge qhov taw qhia:liab=them, ntsuab=puv.
  • Zam kom tsis txhob nyob hauv -them los yog tso tawm tob; khaws cia roj teeb voltagesaum 12 V.
  • Yog tias khaws cia ntev -lub sij hawm, khaws nws kom them tag nrho hauv qhov chaw qhuav, qhov cua ntawm 5-25℃thiab rov them duatxhua 2 lub hlis.

 

Kev Ceeb Toom

 

I/O terminals thiab cov ntawv xeem yuav nyob. Cov pa taws tuaj yeem tshwm sim thaum ntsaws / tshem tawm cov kev xeem coj los yog lub qhov hluav taws xob - ceev faj ntawm hluav taws xob poob siab.

  • Ground lub chassis hauv av ncej nrog rau lub zog - qaum av; xyuas kom zoo grounding ua ntej txuas terminals.
  • Tsuas yog siv hom thiab ntsuas ntawm fuse.
  • Tsis txhob ua haujlwm nrog lub hau npog / vaj huam sib luag tshem tawm, hauv qhov chaw ntub dej, lossis hauv qhov chaw tawg.
  • Kev sib txuas / txiav tawm kev xeem tsuas yog thaum cov terminals de-energized.
  • Tsuas yog cov kws tshaj lij tsim nyog tuaj yeem ua haujlwm; nres siv yog tias lub tsev xav tias puas lawm.

 

FAQ

 

Q: 1. MOEORW-WBT67 ua li cas kom tus neeg teb xov tooj muaj kev nyab xeeb?

A: Txoj hauv av tsim nyog yog yuav tsum tau ua - ob qho tib si ntawm lub hwj chim - qaum av thiab lub chassis hauv av ncej. Tsuas yog cov fuses uas tau teev tseg yog siv, lub hau yuav tsum nyob twj ywm, kuaj cov hlau txuas / txiav tawm tsuas yog thaum de- zog, thiab kev ua haujlwm hauv qhov chaw ntub dej lossis tawg yog txwv. Lub tsev tseem ceeb toom rau lub roj teeb hnyav hauv qab -voltage.

Q: 2. Cov cuab yeej siv tau yooj yim ua haujlwm li cas?

A: Sab hauv pib ntau yam - hloov thiab xaim yooj yim; tsis siv neeg thaiv kev txheeb xyuas nrog cov duab vector nyob; 40 cov khoom pov thawj uas khaws cia; kov cov yuam sij nrog ci LCD; tiag- lub sijhawm moos; vaj huam sib luag thermal tshuab luam ntawv; 500- pab pawg fais fab tuag cia; PC cov ntaub ntawv export; thiab sab nraud VT / CT ntau yam txuas ntxiv.

Q: 3. Yuav tsum khaws cov roj teeb li cas thaum khaws cia ntev?

A: Txheeb xyuas cov nqi ua ntej siv thiab rov them tam sim ntawm qhov qis -voltage ceeb toom. Khaws cia roj teeb voltage siab tshaj 12 V; Yog tias tsis siv rau lub sijhawm ntev, khaws cia kom them tag nrho ntawm 5-25℃hauv qhov chaw qhuav, qhov cua thiab sab saud txhua 2 lub hlis. Lub roj teeb ua ntej - qhib rau ntawm lub hoobkas.

 

 

Cim npe nrov: Tuam Tshoj active transformer muaj peev xwm thiab cov yam ntxwv tester, Tuam Tshoj active transformer muaj peev xwm thiab cov yam ntxwv tester manufacturers, hoobkas

Xa kev nug