Dej-Coled motor DC Withstand Voltage Tester
Khoom Taw Qhia
Dej-Coled Motor DC Withstand Voltage Tester Cov cuab yeej ntsuas no sawv cev rau peb lub tuam txhab tom ntej- tiam, ntse, LCD- tso tawm cov cuab yeej ntsuas tshwj xeeb tsim raws li "qis-voltage shielding" txoj cai thiab tsim los ntawm peb cov khoom siv yav dhau los. Nws ntiav cov thev naus laus zis los ntawm siab - zog DC siab -voltage generators, hloov cov tshuaj ntsuam xyuas ib txwm muaj xws li kev sim transformers, siab -voltage silicon stacks, voltage-stabilizing capacitors, rectifier capacitors thiab inductors, DC siab {{9}μrsA, voltage regulators, mA, thiab voltage regulators polarization tej zaum yuav them cov khoom siv. Tag nrho cov khoom no tau muab tso rau hauv ib qho siab -voltage (generation) unit thiab lub txee tswj. Qhov no txo qis tus naj npawb ntawm tus kheej cov khoom hauv kev teeb tsa ua tiav, txo qhov hnyav ntawm cov cuab yeej ntsuas, ua kom cov haujlwm ua haujlwm rau cov neeg ua haujlwm kuaj sim, ua kom yooj yim rau kev ntsuas cov hlua, thiab ua rau kev sim yooj yim dua, ua tau zoo, thiab txhim khu kev qha. Tsis tas li ntawd, kev tswj hluav taws xob hluav taws xob, kev them nyiaj tsis siv neeg polarization, thiab kev tiv thaiv kev ua haujlwm ua kom yooj yim dua thiab muaj kev nyab xeeb dua. Kev txais yuav qhov nruab nrab- zaus voltage ntau zaus muab ntau qhov kev ntsuas qhov zoo tshaj plaws, ua rau muaj tseeb dua, cov ntaub ntawv xeem ruaj khov thiab cov txiaj ntsig zoo dua.
Khoom Parameter (Specification)
|
Specifications/ Tsis muaj |
60/80 |
60/120 |
60/200 |
60/300 |
80/200 |
80/300 |
90/150 |
100/250 |
|
Cov zis voltage (kV) |
60 |
60 |
60 |
60 |
80 |
80 |
90 |
100 |
|
Cov zis tam sim no (mA) |
80 |
120 |
200 |
300 |
200 |
300 |
150 |
250 |
|
Lub hwj chim (kW) |
4.8 |
7.2 |
12 |
18 |
16 |
nees nkaum plaub |
13.5 |
25 |
|
Chassis hnyav (kg) |
17 |
33 |
35 |
38 |
38 |
39 |
36 |
40 |
|
Siab ntau qhov hnyav (kg) |
18 |
10+24 |
10+24 |
14+37 |
15+36 |
15+37 |
14+25 |
17+38 |
|
Siab ntau lub tog raj kheej qhov siab (mm) |
630 |
730 |
730 |
900 |
900 |
900 |
850 |
1000 |
|
Kev ntsuas hluav taws xob yuam kev |
1.0% ± 2 cim |
|||||||
|
Tag nrho tam sim no ntsuas yuam kev |
1.0% ± 2 cim |
|||||||
|
Kev ntsuas tam sim no tsis raug |
± 2.0% (tag nrho teev) |
|||||||
|
Kev teeb tsa overvoltage yuam kev |
Tsawg dua lossis sib npaug li 1% |
|||||||
|
voltage stability |
1.0% (random fluctuations, fais fab mov voltage variations ± 10%) |
|||||||
|
txoj kev ua haujlwm |
Rated load txuas ntxiv ua haujlwm Tsawg dua lossis sib npaug li 5 feeb |
|||||||
|
Ambient kub |
-10 ° ~ 40 ° C |
|||||||
|
txheeb ze humidity |
Ntawm qhov kub ntawm 25 degree, qhov concentration yuav tsum tsis pub tshaj 90% (tsis muaj condensation). |
|||||||
|
Qhov siab |
Hauv qab 2000 meters |
|||||||
Khoom feature thiab daim ntawv thov
DC tiv taus qhov ntsuas hluav taws xob thiab DC qhov ntsuas tam sim no rau cov dej- cov cav txias tau ua nyob rau hauv ob qho xwm txheej: nrog lossis tsis muaj dej tawm sab nraud. Qhov zoo thiab qhov tsis zoo yog muab piv rau hauv qab no:
1. Kev sim nrog dej tshuab
Qhov zoo: tuaj yeem ua tau siv tus qauv DC siab -voltage testers. Cov khoom siv yog lub teeb yuag, kev ua haujlwm yooj yim, kev nyeem ntawv yog qhov tseeb, thiab cov txiaj ntsig tsis cuam tshuam los ntawm dej zoo.
Disadvantages: Vim lub tshuab hluav taws xob cov qauv, cov dej ntim hauv qab yog qhov nyuaj rau tshuab ziab. Cov txheej txheem no yog lub sij hawm heev -siv, feem ntau yuav tsum tau tshaj ib lub lim tiam ntawm tshuab. Nws ncua lub overhaul downtime. Lub tshuab tsis tiav tsis yog tsuas yog qhia txog kev ntsuas qhov yuam kev, tab sis kuj tseem ua rau muaj kev puas tsuaj rau windings yog tias arcing tshwm sim hauv lub kauj thaum kuaj.
2. Kev sim nrog dej ntws
Qhov zoo: Tshem tawm qhov xav tau ntawm cov khoom siv tshuab thiab txuag lub sijhawm tshuab.
Qhov tsis zoo: Cov txheej txheem tam sim no muab AC test transformers (los yog resonant transformers) nrog silicon stacks thiab capacitors, xav tau cov khoom siv nyiaj polarization ntxiv rau cov kav dej. Cov khoom siv yog loj heev, dispersed, thiab koom nrog complex thaiv. Cov txiaj ntsig kev ntsuas tau cuam tshuam los ntawm cov dej tsis zoo, ua rau muaj qhov hloov pauv ntawm microampere meter thiab nyeem nyuaj.
Xav txog cov saum toj no, kov yeej ob qho kev tsis zoo yuav tsum muaj kev sib koom ua ke tshwj xeeb uas ua rau kev sim hauv qab dej nrog kev txav mus los, yooj yim, thiab raug. Peb lub tuam txhab "Dej-Cooled Generator DC High-Voltage Test Device," tsim los ntawm txoj cai "low-voltage shielding method" hauv paus ntsiab lus, ua tau raws li cov cai no. Nws cov yam ntxwv tseem ceeb suav nrog:
1) Tag nrho cov txheej txheem tsuas yog muaj lub txee tswj thiab lub tshuab hluav taws xob sib txuas, uas muaj cov xaim yooj yim heev.
2) Siv hluav taws xob tswj thiab kho kom yooj yim, ua haujlwm zoo; voltage, tam sim no, thiab lwm yam tsis tau ncaj qha nyeem tau ntawm vaj huam sib luag meters yam tsis muaj kev hloov pauv.
3) suav nrog ib -feeb sijhawm thiab ua haujlwm sai, kho tau raws li cov txheej txheem xeem.
4) Muaj peev xwm tiv thaiv overvoltage thiab overcurrent tiv thaiv.
Kev tsim tawm cov ntsiab lus
Daim ntawv thov tau tsom mus rau kev ntsuas kev ua tau zoo ntawm rwb thaiv tsev rau cov dej-cov motors txias, tshwj xeeb npog cov hauv qab no:
1.Power Generation Side of Power Systems (Core Application Scenarios)
Loj loj hydroelectric generators
Chav turbine generators
2. Muaj tus kheej- muaj cov chaw tsim hluav taws xob / chaw nres tsheb fais fab
Tsim nyog rau tus kheej - muaj hwj chim chaw nres tsheb ntawm cov lag luam loj xws li steel, tshuaj, metallurgical, thiab cement industries, nrog rau cov ntaub ntawv chaw thiab cov chaw nres tsheb hauv nroog
3. Lub cev muaj zog tsim thiab kev lag luam tu
4. Dej-Kev ntsuas lub cev muaj zog hauv cov xwm txheej tshwj xeeb
Lub Tuam Txhab Txuj Ci
Cim npe nrov: dej-tsoov lub cev muaj zog dc tiv taus voltage tester, Tuam Tshoj dej-txias motor dc withstand voltage tester manufacturers, hoobkas