Transformer Test Lub Rooj Zaum

Xa kev nug
Transformer Test Lub Rooj Zaum
Paub meej
MOEORW-W1080X Universal Test Bench: Ib qho - khawm ua tiav cov yam ntxwv ntawm lub tshuab hluav taws xob thiab tiv thaiv qhov ntsuas hluav taws xob. Tshem tawm phau ntawv suav nrog qhov yuam kev tsawg, muaj kev hloov pauv tau zoo thiab tsis muaj teeb meem - ua haujlwm dawb. Muab cov kev ntsuam xyuas zoo thiab meej rau kev tsim khoom, kev ua haujlwm thiab kev saib xyuas, thiab kev tshawb fawb tshawb fawb.
Kev faib tawm yam khoom
Transformer Test Set
Share to
Hauj lwm lawm

Fully Automatic Transformer Comprehensive Test Bench

 

Khoom Taw Qhia

 

Lub MOEORW-W1080X Tag Nrho Tsis Siv Neeg Transformer Comprehensive Test Bench feem ntau sim qhov tsis muaj -load thiab load yam ntxwv ntawm lub zog transformers thiab faib transformers. Nws tseem tuaj yeem ua ob npaug - zaus induction thiab lub zog zaus tuaj yeem ntsuas qhov ntsuas hluav taws xob ntawm cov khoom siv hloov pauv.

Tshooj ntsuas ntawm cov cuab yeej no yog tswj los ntawm lub siab -kawg microcontroller nrog cov zaub. Cov ntaub ntawv ntsuas tsis muaj-load, luv-circuit, thiab lwm yam kev mob yog synchronously sampled los ntawm microcontroller, tshem tawm kev ntsuas yuam kev tshwm sim los ntawm phau ntawv muab xam los ntawm cais cov nyeem ntawm voltmeters, ammeters, thiab wattmeters nyob rau hauv ib txwm sim txoj kev.

 

Khoom Parameter (Specification)

 

Qhov project

Kev ntsuas ntau

txheeb ze yuam kev

Qhov hluav taws xob

0.1-650V

+ (0.2% ntawm kev nyeem ntawv + 0.1% ntawm qhov ntau)

Tam sim no

0.1-200A

+ (0.2% ntawm kev nyeem ntawv + 0.1% ntawm qhov ntau)

zog

U*I

+ (0.2% ntawm kev nyeem ntawv + 0.1% ntawm qhov ntau)

Fais fab xwm txheej

0.1~0.9999

+ 3%

Hloov pauv

1.000-9999.9

Qib0.2

Pab pawg

00-11

 

fais fab mov

AC380V 3+ 10% 50Hz+ 2 %

Kev siv ib puag ncig

Kev khiav hauj lwm kub: 0 ​​~ 40 degree; txheeb ze humidity: 30% ~ 90%.

 

Khoom feature thiab daim ntawv thov

 

1. **Ua raws li Cov Qauv**: Ua tau raws li lub teb chaws cov qauv xws li GB/T4776, GB/T5169, thiab GB/4285-1993, kom ntseeg tau tias muaj kev pov thawj thiab siv tau thoob ntiaj teb.

2. **Comprehensive Functionality**: Ua tsis tau -load/load characteristic tests, power frequency withstand voltage tests, and double-frequency induction tests. Ntsuas cov ntsiab lus tseem ceeb suav nrog voltage, tam sim no, lub zog, thiab qhov sib piv.

3. **Superior Accuracy**: Siv high-kawg microcontroller-raws li kev tswj nrog synchronous cov ntaub ntawv sampling, tshem tawm phau ntawv nyeem thiab xam yuam kev. Qhov tseem ceeb parameter ntsuas txheeb ze yuam kev tsawg li 0.2% ntawm kev nyeem ntawv + 0.1% ntawm tag nrho cov nplai.

4. **Tus neeg siv-Kev Ua Haujlwm Zoo**: Cov duab digital nrog lub teeb pom kev meej. Cov haujlwm tseem ceeb ua tiav ntawm cov nyees khawm. Txhawb cov ntaub ntawv luam tawm. Streamlined workflow kom yooj yim kawm.

5. ** Muaj kev nyab xeeb thiab txhim khu kev qha **: Nruab nrog kev nres thaum muaj xwm ceev thiab tsis siv neeg tiv thaiv hluav taws xob txo. Kev cuam tshuam sai sai rau kev sim thaum muaj kev tsis sib haum xeeb los tiv thaiv cov khoom siv thiab cov neeg ua haujlwm.

6. **High Adaptability**: Voltage measurement range 0.1–650V, tam sim no 0.1–200A, lem ratio 1.000–9999.9, haum rau cov kev xav tau sib txawv rau cov transformers fais fab, faib transformers, thiab lwm yam qauv kuaj.

 

Kev tsim kho cov ntsiab lus

 

Cov ntawv thov tseem ceeb suav nrog kev kuaj kev lees paub hauv lub Hoobkas, kev kuaj kev lees paub, thiab kev tiv thaiv kev saib xyuas rau lub zog transformers thiab faib transformers. Nws haum rau kev ua haujlwm niaj hnub thiab tiv taus qhov ntsuas hluav taws xob rau cov chaw tsim khoom siv hluav taws xob, lub zog ua haujlwm thiab kev saib xyuas, thiab cov chaw tshawb fawb.

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

1) Thaum lub sijhawm sim ua haujlwm nrog MOEORW-W1080X Tag Nrho Tsis Siv Neeg Transformer Comprehensive Test Bench, yuav ua li cas thiaj li yuav daws tau qhov teeb meem txawv txav sai?

Teb: Yog tias qhov tsis sib xws tshwm sim thaum kuaj (piv txwv li, thaum lub sijhawm hluav taws xob- nce qib), nias lub pob "Emergency Stop". Kev ntsuam xyuas yuav nres tam sim ntawd, thiab qhov ntsuas hluav taws xob yuav cia li txo qhov voltage. Tom qab cov cuab yeej ruaj khov, tshawb xyuas qhov ua rau ntawm qhov txawv txav. Thaum daws tau lawm, rov pib dua cov cuab yeej raws li tus txheej txheem thiab rov pib kuaj.

2) Dab tsi yog qhov sib txawv hauv kev xaim ntawm qhov tsis muaj- thauj khoom thiab thauj khoom thaum lub sijhawm kuaj tus yam ntxwv ntawm MOEORW-W1080X tag nrho tsis siv neeg hloov pauv kev ntsuas lub rooj zaum?

Teb: Yog tsis muaj- load testing, txuas lub "Connect Tested Transformer" davhlau ya nyob twg ntawm lub rooj zaum sim mus rau qhov qis -voltage sab ntawm lub transformer kuaj. Txoj hlua hluav taws xob rau kev ntsuas kev thauj khoom zoo ib yam tsis muaj - thauj khoom kuaj, tab sis "Connect Tested Transformer" lub davhlau ya nyob twg yuav tsum tau txuas mus rau qhov siab -voltage sab ntawm qhov ntsuas transformer, thiab qis -voltage sab yuav tsum luv-circuited.

3) Thaum ua ob npaug - kev sim zaus ntawm MOEORW-W1080X tag nrho tsis siv neeg hloov pauv kev ntsuas lub rooj zaum, yog tias ntau lub tshuab hloov pauv yuav tsum tau sim sib txuas, puas yog qhov yuav tsum tau rov pib lub tshuab hluav taws xob txhua zaus?

Teb: Tsis yog. Tom qab ua tiav ob - zaus tiv thaiv qhov ntsuas hluav taws xob rau ib lub tshuab hloov pauv, nias lub pob "Function Reset" txhawm rau npaj rau qhov kev sim tom ntej. Lub tshuab hluav taws xob tsis tas yuav tsum tau nres. Tom qab txhua qhov kev xeem tiav, nias lub pob "Generator Stop" kom kaw lub tshuab hluav taws xob.

 

Cim npe nrov: Tuam Tshoj transformer test bench manufacturers, hoobkas

Xa kev nug