Portable Transformer Winding Fault Analyzer

Xa kev nug
Portable Transformer Winding Fault Analyzer
Paub meej
MOEORW-WBX16 siv high precision zaus teb tshuab los txiav txim winding noj qab haus huv sai.
Nws nta kev sib txuas wireless, tsim qauv tsim thiab yooj yim ntawm qhov chaw ua haujlwm.
Nws yog dav siv rau niaj hnub kuaj thiab kev kuaj mob ntawm lub hwj chim transformers.
Kev faib tawm yam khoom
Transformer Winding Deformation Tester
Share to
Hauj lwm lawm

Khoom Taw Qhia

 

MOEORW-WBX16 transformer winding deformation tester sivsiab -kev soj ntsuam zaus tebraws li txoj kev tshawb nrhiav tseem ceeb, tshwj xeeb tshaj yog tsim los rau kev kho sai thiab tsis yog -kev puas tsuaj ntawm transformer winding kev noj qab haus huv. Nws txais kev tswj hwm microprocessor sib xyaw ua ke thiab siab - nrawm A / D sampling, uas tuaj yeem ntes cov yam ntxwv tsis hloov pauv los ntawm winding deformation. Cov cuab yeej txhawb nqa txoj kab thiab ntu ob hom cheb, thiab tuaj yeem ua tiav peb - theem kev sib piv thiab cov ntaub ntawv keeb kwm kev txheeb xyuas. Nws ua tau raws li DL/T911-2016 tus qauv thiab tsim nyog rau ntawm qhov chaw ceev nrhiav pom ntawm 63kV-500kV transformers.

 

Khoom Parameter (Specification)

 

Luam theej duab ntau zaus 10Hz-10MHz (linear), 0.5kHz-1MHz (sab ntu)
Amplitude ntau -120dB ~ +20dB, daws teeb meem: 0.1dB
Ntau zaus 0.005%
I / O impedance input 1MΩ, tso zis 50Ω
Tso zis teeb liab ±20V
Kuaj repeatability 99.9%
Ua haujlwm kub -10℃~ +40 degree
Khoom loj 370 × 300 × 170mm Nyhav: 13kg
Kev sib txuas USB / WIFI / Bluetooth

 

Khoom Feature

 

  • Tshwj xeeb zaus teb txoj kev, siab rhiab heev thiab muaj zog stability
  • Dual cheb hom kom tau raws li qhov xav tau sib txawv
  • High -kev ntsuas ceev, pom tseeb waveform sib txawv nyob rau hauv txawv kais dej
  • Txhawb wireless WIFI / Bluetooth kev twb kev txuas, mobile tswj muaj
  • Tsis siv neeg nkhaus tsom xam thiab deformation theem txiav txim
  • Cov qauv sib sib zog nqus, yooj yim nqa mus rau ntau zaus ntawm - qhov chaw sim
  • Tsis siv neeg cov ntaub ntawv khaws cia thiab tshaj tawm cov ntaub ntawv, yooj yim rau kev khaws cia
  • Kev xaim yooj yim, tsis xav tau lub hau npog, txo kev siv zog

 

Khoom siv

 

  • Kev ntsuas kev tiv thaiv niaj hnub ntawm hauv - kev pabcuam transformers hauv substations
  • Qhov chaw ceev ceev tom qab transformer luv Circuit Court lossis cuam tshuam
  • Kev tshuaj xyuas lub Hoobkas thiab ex- Hoobkas kuaj ntawm kev faib khoom transformers
  • Kev txheeb xyuas lub xeev ua ntej kab sib txuas thiab tom qab kev kho
  • Winding qauv xyuas tom qab ntev - kev thauj mus los
  • Haum rau 63kV–500kV ib leeg / peb-theem transformers ntawm ntau yam thaiv

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

 

Q1: Vim li cas thiaj yuav tsum tau ua qhov kev ntsuam xyuas zaus ua ntej tom qab fais fab tuag?

A: Tiv thaiv cov cores saturation los ntawm DC kev ntsuam xyuas (xws li DC tsis kam), uas yuav ua rau cov ntaub ntawv tsis raug.

Q2: Txoj kev hauv av yog dab tsi?

A: Txuas cov lus teb hauv av clamp rau excitation av clamp ua ntej, ces txuas mus rau transformer core grounding point.

Q3: Kuv puas tuaj yeem siv lub xov tooj ntawm tes los ua qhov kev xeem?

A: Yog, txuas WIFI (lub npe: winding deformation, password: 12345678) thiab siv tshwj xeeb APP.

Q4: Ntev npaum li cas cov hlau lead sab nraud yuav tsum nyob deb ntawm bushings?

A: Tag nrho cov hlau lead yuav tsum raug txiav thiab khaws cia ntau tshaj 20cm deb ntawm bushings.

Q5: Yuav ua li cas txuag thiab saib cov ntaub ntawv xeem?

A: Cov ntaub ntawv khaws cia hauv ASCII hom, uas tuaj yeem qhib, kho thiab thaub qab los ntawm cov ntawv nyeem software.

 

Cim npe nrov: Tuam Tshoj portable transformer winding txhaum analyzer, Tuam Tshoj portable transformer winding txhaum analyzer manufacturers, hoobkas

Xa kev nug