Roj Trace Moisture Tester

Xa kev nug
Roj Trace Moisture Tester
Paub meej
ME-W105 Trace Moisture Analyzer ntiav Karl Fischer coulometric titration method, sib xws nrog cov khoom siv, kua, thiab cov qauv roj. Features 64K-xim touchscreen zaub txhawb lub sijhawm tiag tiag- hloov pauv ntawm 8 cov qauv kev suav nrog kov- hloov nrawm nrawm. Kev kuaj pom ntau: 1ug-100mg; rhiab heev: 0.1ug; yuam kev tsawg li ± 2ug / 0.3%. Khaws txog 1000 cov ntaub ntawv nrog 50VA tsawg zog noj. Dav siv rau kev txiav txim siab qhov dej noo ntawm ntau yam kev lag luam.
Kev faib tawm yam khoom
Cov Khoom Siv Roj Xeem
Share to
Hauj lwm lawm

ME -W105 Trace Oil Trace Moisture Tester

 

Khoom Taw Qhia

 

ME-W105 Trace Moisture Analyzer yog ib qho cuab yeej tsim kho tshiab rau kev txiav txim qhov dej noo. Featuring lub siab - daws teeb meem xim touchscreen LCD zaub, nws muaj intuitive tib neeg- tshuab kev sib cuam tshuam thiab kev ua haujlwm tsis muaj zog. Nruab nrog lub siab -kev ua tau zoo ARM processor uas muab cov ntaub ntawv loj khaws cia, kev ua haujlwm nrawm thiab ruaj khov, thiab muaj peev xwm tiv thaiv tau zoo heev - cuam tshuam, qhov ntsuas tau zoo tshaj plaws hauv kev tshawb nrhiav ceev thiab siab. Nws suav nrog tus kheej- kev kuaj mob ua haujlwm thiab tso tawm thiab luam tawm cov txiaj ntsig thaum kuaj tiav. Cov cuab yeej qhia dynamic ntsuas muaj peev xwm nkhaus rau intuitive saib xyuas. Nws khaws cia txog 1000 cov ntaub ntawv cov ntaub ntawv thiab suav nrog kev ntsuas ncua sij hawm, tshwj xeeb tshaj yog siv tau rau cov qauv uas muaj cov dej noo tsawg. Ib qho zawv zawg kov-tswj stirrer muab kev hloov pauv ceev. Cov qauv ntsuas dej noo suav nrog ntau lub algorithms raws li qhov tseem ceeb tsis xws li ntim thiab qhov hnyav. Thaum lub sij hawm sim, cov tsis muaj feem cuam tshuam ntawm cov mis laij lej tuaj yeem hloov kho tau tiag tiag -lub sijhawm yam tsis muaj kev cuam tshuam rau kev txiav txim siab noo noo. Cov ntsiab lus noo noo yog xam raws li cov kev hloov tshiab tshiab, txhim kho cov neeg siv khoom yooj yim.

Cov cuab yeej no siv Karl Fischer coulometric coulometric titration txoj hauv kev los txiav txim siab cov dej noo hauv cov kua, roj, thiab cov qauv khoom. Rau cov khib nyiab insoluble nyob rau hauv reagents los yog cov khoom muaj feem xyuam rau cov kab mob electrodes thiab reagent cov tshuaj tiv thaiv, coj cov khoom, roj, los yog kua samplers yuav siv tau rau indirect ntsuas. Qhov no muaj txiaj ntsig zoo, tag nrho cov cuab yeej siv tshuaj ntsuam xyuas pom pom ntau daim ntawv thov thoob plaws hauv kev lag luam suav nrog kev tsim hluav taws xob, roj av, tshuaj engineering, tshuaj, kev tsheb ciav hlau, kev tiv thaiv ib puag ncig, thiab cov chaw tshawb fawb.

 

Khoom Parameter (Specification)

 

1. Txoj Kev Titration

Coulometric Titration (Coulometric Analysis)

2. Kev ntsuas qhov ntsuas

1 ug 100 mg

3. Electrolysis tam sim no

0-400 mA

4. Kev kuaj pom tsis pub dhau

0.1 ua

5. Qhov tseeb

5 ug H₂O rau 1 mg H₂O; ± 2 ug; Saum 1 mg H₂O; 0.3% (tsis suav cov qauv thauj khoom yuam kev thiab ib puag ncig cov av yuam kev)

6. Hom qauv

Khoom, kua, Gas

7. Txoj kev tso saib

64K-xim siab- txhais touchscreen

8. Cov ntaub ntawv khaws cia

1000 cov ntaub ntawv xeem

9. Kev taw qhia txog xwm txheej

Dynamic nkhaus, ntawv nyeem

10. stirring ceev tswj

Sliding touch vaj huam sib luag ceev hloov

11. Lub tshuab luam ntawv

Mini thermal tshuab luam ntawv, ntawv dav 56mm

12. Fais fab mov

AC 220V ± 10V, 50Hz ± 2.5Hz

13. Kev ntsuas fais fab

50 VA

14. Kev ua haujlwm kub

5-35 degree

15. Kev khiav dej num

Tsawg dua lossis sib npaug li 85%

16. Qhov ntev

330mm × 260mm × 220mm (L × W × H)

 

Khoom feature thiab daim ntawv thov

 

1. Cov yam ntxwv yooj yim siv suav nrog kev piav qhia cov xwm txheej zoo, yim tiag tiag - lub sijhawm hloov kho cov qauv, 64K xim touchscreen zaub, thiab swb - rau- kho ceev tswj.

2. Superior Performance: High rhiab heev ntawm 0.1ug, kev ntsuas dav ntawm 1ug mus rau 100mg, thiab kev ua yuam kev tsawg li ± 2ug / 0.3% ua tsaug rau ARM CPU.

3. Tag nrho -Kev Ua Haujlwm suav nrog: Muab kev ntsuas qeeb thiab tsis siv neeg luam ntawv rau ntau yam kev siv, khaws 1000 cov ntaub ntawv cov ntsiab lus, thiab txhawb nqa cov khoom siv, kua, thiab cov qauv ntsuas roj.

4. Kev Kho Kom Yooj Yim: Kev sib cog lus thiab lub zog- tsim tau zoo (50VA), muaj zog reagent compatibility, ntshiab tu raws tu qauv rau cov khoom tseem ceeb, thiab haum rau ntau yam sectors.

 

Kev tsim kho cov ntsiab lus

 

ME-W105 Trace Moisture Analyzer ntiav Karl Fischer coulometric titration txoj kev los txiav txim cov kab dej noo hauv cov khoom, kua, thiab cov qauv gaseous. Nws pom ntau daim ntawv thov thoob plaws kev lag luam suav nrog kev tsim hluav taws xob, roj av, tshuaj engineering, tshuaj, kev tsheb ciav hlau, kev tiv thaiv ib puag ncig, thiab cov chaw tshawb fawb.

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

1) Cov qauv twg tuaj yeem ntsuas ME -W105 Trace Moisture Analyzer ntsuas?

Teb: Cov cuab yeej no ntseeg tau tias ntsuas cov dej noo hauv cov khoom, kua, thiab cov qauv gaseous. Rau cov khib nyiab insoluble nyob rau hauv reagents los yog cov khoom uas yuav kis tau electrodes los yog cuam tshuam nrog reagent cov tshuaj tiv thaiv, coj cov khoom, roj, los yog kua samplers yuav siv tau rau indirect ntsuas, haum rau ntau yam complex qauv scenarios.

2) Tus neeg siv dab tsi -tus phooj ywg zoo li ME-W105 taug qab ya raws tus ntsuas qhov sib cuam tshuam?

Teb: Cov cuab yeej muaj qhov siab -txhais lus touchscreen zaub rau kev nkag siab ntawm tib neeg- tshuab kev sib cuam tshuam. Cov haujlwm tseem ceeb-xws li kev hloov hluav taws xob, nplawm pib / nres, thiab kev sim pib- yog pib nrog ib qho - khawm tswj. Kev ntsuas kev kawm tau tshwm sim hauv lub sijhawm tiag tiag ntawm ob qhov ntsuas: dynamic curves thiab cov ntawv hloov tshiab. Nws txhawb kev hloov kho cov qauv kev xam cov dej noo thiab cov tsis muaj feem cuam tshuam thaum kuaj tsis cuam tshuam cov txiaj ntsig, muab kev ua haujlwm siab ua haujlwm.

3) Dab tsi yuav tsum tau ceev faj txog kev siv reagent thiab cia rau ME -W105 Trace Moisture Analyzer?

Teb: Thaum lub sij hawm siv, yog tias reagent rhiab heev txo qis vim qhov kev sim ntev, yog tias muaj npuas ntau dhau thaum lub sij hawm titration los yog cov reagent hloov reddish -xim av, los yog yog tias qhov ntsuas tseem tsis ruaj khov tom qab 30 feeb ntawm titration uas tsis pom cov xim av iodine tso rau hauv qab ntawm cov plooj (porcelain) lim phaj. Tsis txhob nqus los yog tawv nqaij nrog cov reagent thaum hloov; yog tias muaj kev sib cuag, yaug kom huv si nrog dej. Rau kev khaws cia, khaws cov tshuaj reagents nyob rau hauv lub qhov dej zoo- qhov cua qhov chaw nrog qhov kub ntawm 5℃thiab 25℃thiab cov av noo tsis tshaj 65%. Tsis txhob raug tshav ntuj ncaj qha los yog qhov kub thiab txias los tiv thaiv reagent degradation.

 

Cim npe nrov: Tuam Tshoj roj trace noo noo tester manufacturers, hoobkas

Xa kev nug