Comprehensive Electrical Equipment Testing System

Xa kev nug
Comprehensive Electrical Equipment Testing System
Paub meej
Ib lub cuab yeej ua tiav tag nrho cov kev ntsuas hluav taws xob, txuag lub sijhawm, nqi thiab qhov chaw. High precision, muaj zog tiv thaiv - cuam tshuam, ua haujlwm yooj yim thiab cov ntaub ntawv ruaj khov. Txhim kho kev sim ua kom zoo dua qub, txo cov cuab yeej siv peev thiab ua kom muaj kev nyab xeeb ntawm cov khoom siv fais fab.
Kev faib tawm yam khoom
Transformer Test Set
Share to
Hauj lwm lawm

Khoom Taw Qhia

 

MOEORW-W4008 yog ib qho kev sib koom ua ke zoo heev, network- cov khoom siv hluav taws xob cov khoom siv hluav taws xob sib xyaw ua ke nrog lub hauv paus tswj kev ua haujlwm sib cuam tshuam. Nws koom ua ke ntau yam kev sim ua haujlwm rau hauv ib chav, txo qhov ntim thiab qhov hnyav, ua haujlwm raws li qhov ntsuas ntawm lub xov tooj ntawm tes thiab tsheb- mounted hluav taws xob kuaj tshuab. Nws tuaj yeem ua tiav qhov kev tiv thaiv, AC parameter, thiab kev ntsuas kev ntsuas hluav taws xob rau kev hloov pauv, cov kab sib kis, cov neeg ntes, thiab cov khoom siv hauv av, dav siv hauv kev tshuaj xyuas cov khoom siv hluav taws xob, kev kuaj xyuas lub Hoobkas, thiab ntawm - kev saib xyuas qhov chaw.

 

Khoom Parameter (Specification)

 

Lub zog ua haujlwm

AC220V ± 10%

Ambient Kub

-10 ~ 40 degree

Zaub

7-nti xim kov LCD

Cov ntaub ntawv khaws cia

100 cov ntaub ntawv rau ib qho kev xeem (lub zog-tawm tsis yog- tsis hloov pauv)

Kev sib txuas lus Interface

RS-485, USB, wireless

Ua -hauv

Micro tshuab luam ntawv

Qhov ntsuas ntsuas tseem ceeb

Transformer DC Resistance

100μΩ ~ 10kΩ, qhov tseeb 0.2% ± 2 tus lej

Loop Resistance

0 ~ 20mΩ, qhov tseeb ± 0.5% ± 3 tus lej

Transformer tig ratio

0.8 ~ 5000, qhov tseeb ± 0.1% ± 2 tus lej

AC voltage

0 ~ 800V, qhov tseeb ± 0.2% ± 2 tus lej

AC tam sim no

0 ~ 80A, qhov tseeb ± 0.2% ± 2 tus lej

Arrester Leakage Current

0 ~ 20mA, qhov tseeb ± 5% ± 3 tus lej

Dielectric Loss

± 1% ± 0.0004, ntau yam 3pF ~ 1.5μF

 

Khoom Feature

 

  • Kev koom ua ke siab: Muab cov kev tiv thaiv, AC parameter, thiab kev ntsuas hluav taws xob hauv ib lub cuab yeej.
  • Kev ua haujlwm yooj yim: Cov ntawv qhia zaub mov suav puv thiab 7-nti kov npo rau kev tswj kom paub tseeb.
  • Siab Precision: Ntau-ntau thiab siab- ntsuas qhov tseeb rau ntau qhov ntsuas hluav taws xob.
  • Muaj zog tiv thaiv - cuam tshuam: zaus hloov tshuab rau qhov tseeb dielectric poob kev sim hauv kev cuam tshuam muaj zog.
  • Yooj Yim Tswj Cov Ntaub Ntawv: Cov ntaub ntawv khaws cia, USB xa tawm, tsim ua - hauv kev luam ntawv, thiab lub zog - tawm kev tiv thaiv.
  • Kev sib txuas lus ntau: Wired RS-485 thiab wireless kev sib txuas lus rau tej thaj chaw deb cov ntaub ntawv kis tau tus mob.
  • Kev ntsuas dav dav: Npog transformers, kis kab, ntes, grounding systems, thiab lwm yam.

 

Khoom siv

 

  • Transformer Test: DC tsis kam, qhov sib piv, qhov tsis zoo, luv -circuit impedance, muaj peev xwm tsom xam.
  • Transmission Line Test: Positive/zero-sequence impedance, capacitance, mutual inductance parameters.
  • Grounding System Test: Grounding lead conduction, grounding wire group test.
  • Rwb thaiv tsev khoom Test: Zinc oxide arrester nyob xeem, dielectric poob xeem.
  • Siv tau Scenarios: Fais fab nroj tsuag, substation, fais fab mov chaw ua hauj lwm, hluav taws xob khoom Hoobkas, nyob rau hauv - qhov chaw kuaj hluav taws xob.

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

 

Q: Yuav ua li cas xaiv qhov ntsuas tam sim no rau DC qhov ntsuas tsis kam?

A: Xaiv raws li qhov ntsuas tsis kam; siv tsis siv neeg lossis qhov siab tshaj plaws rau kev ua haujlwm me me. Tsis txhob tshaj cov cuab yeej tiv taus tam sim no.

Q: Dab tsi yuav tsum tau sau tseg rau ntawm -kev nyab xeeb ntawm qhov chaw thaiv?

A: Txhim khu kev txhim kho cov cuab yeej; tos kom tiav kev tso tawm ua ntej disconnecting xeem leads; tsis txhob kov qhov siab - qhov hluav taws xob thaum kuaj.

Q: Yuav ua li cas tswj cov ntaub ntawv hla dhau?

A: Cov cuab yeej khaws cia txog 100 cov ntaub ntawv; luam tawm lossis xa tawm cov ntaub ntawv hauv lub sijhawm kom tsis txhob overwriting.

Q: Yuav ua li cas yog tias ntsuas cov ntaub ntawv hloov pauv?

A: Txheeb xyuas qhov ruaj khov ntawm cov hlua khi, kev ntseeg siab hauv av, kuaj kab puas tsuaj, thiab ntawm - cuam tshuam qhov chaw; siv hom kev hloov pauv zaus rau kev ntsuas dielectric poob.

Q: Nws puas tuaj yeem kuaj ib zaug -theem thiab peb-theem khoom?

A: Yog, nws txhawb nqa ib zaug -theem, peb-theem peb-hlau, thiab peb-theem plaub-hloov kev sim nrog cov kab xaiv xaiv.

 

Cim npe nrov: Tuam Tshoj Comprehensive Electrical Equipment Test System, Tuam Tshoj Comprehensive Electrical Equipment Testing System manufacturers, hoobkas

Xa kev nug