Khoom Taw Qhia
MOEORW-WZ-TEV-AA yog ib qho kev sib xyaw ua ke ntawm cov khoom siv hluav taws xob ua kom zoo rau cov khoom siv sab nraum zoov xws li lub nplhaib tseem ceeb thiab lub thawv- hom substations. Nws tau txais kev tshawb pom dual thev naus laus zis ntawm TEV thiab AA, uas tuaj yeem nkag siab nkag siab txog kev cuam tshuam sab hauv hluav taws xob tawm ntawm cov khoom siv.
Lub sensor nta tag nrho CNC txhuas vaj tse thiab epoxy resin tag nrho cov txheej txheem potting, muab cov dej tsis zoo, plua plav thiab tiv thaiv- kev ua haujlwm corrosion kom hloov mus rau qhov nyuaj sab nraum zoov ib puag ncig. Tus tshiab daisy- saw fais fab thiab kev sib txuas lus tsim tso cai rau 16 sensors txuas nrog ib lub cable, txo cov nqi xaim. Lub ua tau - nyob rau hauv siab - microprocessor kev ua tau zoo soj ntsuam thiab ua cov cim sau nyob rau hauv lub sij hawm, ncaj qha outputting tus yam ntxwv qhov tseem ceeb xws li tso tawm ncov thiab mem tes suav.
Khoom Parameter (Specification)
|
Hom Kev Ntsuas |
Parameter |
Tus nqi |
|
AA Ultrasonic tshuab |
Dynamic Range |
0-65dBuV |
|
Center zaus |
40 KHz |
|
|
Repeatability yuam kev |
Tsawg dua lossis sib npaug ± 5% |
|
|
TEV |
Dynamic Range |
0-65 dBmV |
|
Bandwidth |
3MHz-100MHz |
|
|
Pulse suav yuam kev |
Tsawg dua lossis sib npaug ± 5% |
|
|
Kev sib txuas lus |
Interface |
RJ45 Ethernet |
|
raws tu qauv |
Modbus RTU |
|
|
Fais fab mov |
DC 24 V |
|
|
Kev teeb tsa |
Sib nqus (Cabinet Surface) |
|
|
Ib puag ncig |
Kub: -40 ° ~ 85 ° C, Humidity: 5% ~ 95% non-condensing |
Khoom nta
- Lub cim tshiab ntse algorithm, txo qis lub tswb tsis tseeb los ntawm 30%
- Muaj-qib CNC sib nqus tsim, Ntau dua lossis sib npaug rau 50N adsorption quab yuam, ruaj khov nyob rau hauv ib puag ncig kev co
- Kub-swappable daisy- saw architecture, hloov sensor yam tsis muaj hluav taws xob kaw
- Ua-nyob rau hauv watchdog circuit, tsis siv neeg rov pib dua ntawm qhov txawv txav, ua kom ntev - lub sij hawm cia siab
- Standard Modbus 485 raws tu qauv, seamless txuas rau SCADA thiab EMS systems
Khoom siv
- Sab nraum lub nplhaib tseem ceeb (RMU) ntev - lub sij hawm saib xyuas online
- Lub thawv- hom substation rwb thaiv tsev ntsuas qhov ntsuas
- Distribution automation system PD saib xyuas nodes
- Txoj kev teeb pom kev zoo faib txee chaw taws teeb saib xyuas
- Tshiab zog them chaw nres tsheb fais fab khoom saib xyuas
Lub Tuam Txhab Txuj Ci
FAQ
Q1: Qhov txawv ntawm tus qauv no thiab WP70 yog dab tsi?
A: Cov qauv no tau ua kom zoo rau qhov chaw sab nraum zoov, nrog kev txhim kho kev tiv thaiv - kev vibration thiab tiv thaiv - kev ua haujlwm corrosion, thiab ua tau - nyob rau hauv watchdog circuit kom muaj kev ntseeg siab dua.
Q2: Cov sensors puas tuaj yeem hloov pauv yam tsis muaj hluav taws xob tag nrho?
A: Yog. Qhov kub -swappable daisy- saw saw tsim tso cai hloov ib qho sensor tsis cuam tshuam rau kev ua haujlwm ntawm lwm cov sensors hauv cov saw hlau.
Q3: Cov ntaub ntawv dab tsi ua rau lub sensor tso tawm?
A: Nws tso tawm tiag tiag - lub sijhawm tso tawm tus nqi siab tshaj plaws, suav cov mem tes thiab cov teeb liab siv, uas tuaj yeem siv ncaj qha rau kev ntsuas cov khoom siv.
Q4: Puas yog nws sib haum nrog thib peb - tog saib xyuas lub zog?
A: Yog. Nws siv tus qauv Modbus RTU raws tu qauv, uas tuaj yeem txuas nrog rau SCADA, EMS thiab lwm yam kev saib xyuas lub zog loj.
Cim npe nrov: ntse sab nraum zoov pd sensor, Tuam Tshoj ntse sab nraum zoov pd sensor manufacturers, hoobkas