TEV-AA 2-in-1 Dual PD Sensor

Xa kev nug
TEV-AA 2-in-1 Dual PD Sensor
Paub meej
Ua ke TEV sab hauv kev kuaj pom thiab AA qhov chaw paug tawm kom pom.
Dual -channel ntxiv kev txheeb xyuas txhim kho qhov kev kuaj pom qhov tseeb los ntawm 40%.
Square magnetic tsim haum zoo kawg nkaus ntawm cov hlau-clad switchgear sab hauv.
Kev faib tawm yam khoom
Partial Discharge Sensor
Share to
Hauj lwm lawm

Khoom Taw Qhia

 

MOEORW-WTEV-AA yog dual-channel ib feem tso tawm sensor uas sib txuas nrog Transient Earth Voltage detection thiab Airborne Ultrasonic detection technology, tsim los rau kev saib xyuas cov hlau-clad switchgear.

Lub TEV channel txheeb xyuas qhov kev puas tsuaj ntawm cov rwb thaiv tsev sab hauv thiab kev sib cuag tsis zoo los ntawm kev txheeb xyuas cov cim hluav taws xob hloov pauv ntawm lub txee nto; AA channel kuaj pom qhov paug tawm ntawm cov insulators, bushings thiab busbars los ntawm kev ntes cov cim ultrasonic generated los ntawm paug. Ob qhov kev tshawb nrhiav thev naus laus zis ntxiv rau ib leeg kom paub qhov txawv ntawm PD tiag tiag los ntawm - qhov chaw cuam tshuam, txhim kho qhov tseeb ntawm qhov kev txiav txim txhaum cai. Txoj kev sib nqus adsorption installation tsis ua rau cov cuab yeej ua kom puas thiab tso cai rau kev xa tawm sai.

 

Khoom Parameter (Specification)

 

Hom Kev Ntsuas

Parameter

Tus nqi

TEV

Bandwidth

3MHz-100MHz

AA

Center zaus

40 KHz

Dynamic Range

60dB ib

 

Hom

Square Magnetic Mount

 

Khoom siv tsev

Hlau

 

Interface

BNC (SMA customizable)

 

Ua haujlwm kub

-40℃~ +85 degree

 

Kev teeb tsa

Sib nqus (khoom siv sab hauv nto)

 

 

Khoom nta

 

  • TEV + AA dual-channel synchronous nrhiav kom pom, ntxiv kev txheeb xyuas txhim kho kev kuaj mob raug
  • Square magnetic tsim, ruaj khov installation ntawm hlau-clad switchgear sab hauv
  • Integrated tsim txo cov sensor kom muaj nuj nqis, txo qhov system complexity thiab tu nqi
  • Tshawb pom ob qho tib si sab hauv hlau tawm thiab qhov chaw rwb thaiv tsev
  • Customizable interfaces, sib xws nrog mainstream PD saib xyuas hosts

 

Kev tsim kho cov ntsiab lus

 

  • Hlau -clad switchgear dual-channel saib xyuas online
  • Substation switchgear tsis tu ncua soj ntsuam
  • Lub thawv- hom substation rwb thaiv tsev ntsuas qhov ntsuas
  • Industrial automation fais fab khoom saib xyuas
  • Data center fais fab kev faib system tu

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

 

Q1: Dab tsi yog qhov zoo ntawm dual- channel nrhiav pom piv rau ib qho -channel?

A: TEV kuaj pom cov paug tawm sab hauv thiab AA kuaj pom qhov paug tawm, kev txheeb xyuas ntxiv txo qis lub tswb tsis tseeb ntau dua 40%.

Q2: Lub teeb liab interface puas tuaj yeem kho tau?

A: Yog. Txheem BNC interface yog muab, thiab SMA interface tuaj yeem hloov kho raws li cov neeg siv khoom xav tau.

Q3: Dab tsi yog qhov siab tshaj plaws nrhiav tau deb ntawm AA channel?

A: Qhov kev kuaj pom tau zoo yog 0-5 meters, uas tuaj yeem npog tag nrho qhov chaw sab hauv ntawm tus qauv hloov pauv.

Q4: Puas yuav tsum tau calibration ua ntej siv?

A: Lub sensor tau raug Hoobkas ntsuas thiab tuaj yeem siv ncaj qha tom qab kev teeb tsa. Kev ntsuas txhua xyoo raug pom zoo rau kev siv sijhawm ntev -.

 

Cim npe nrov: tev-aa 2-in-1 dual pd sensor, Tuam Tshoj tev-aa 2-in-1 dual pd sensor manufacturers, hoobkas

Xa kev nug