MOEORW-WKQ606B cov cuab yeej yog ua tiav tandem ob -plunger reciprocating siab- siab ua kua xa system, kho kom muaj nuj nqis nrhiav pom cov khoom qub furfural hauv transformer insulating roj hauv kev lag luam fais fab. Nws koom ua ke infusion twj tso kua mis, sampling unit thiab txhawb kev tshawb nrhiav Cheebtsam raws li ib tug tag nrho - nyob rau hauv - ib qho kev daws teeb meem, txhawb isocratic thiab binary siab -pressure gradient elution hom, tag nrho sib xws nrog complex matrix qauv ntawm insulating roj. Tus nqi ntws thiab siab ruaj khov yog ntsuas los ntawm lub Hoobkas qub, nruab nrog ua tiav los tiv thaiv - zoo li qub thiab siab - kev tiv thaiv kev ruaj ntseg. Nws tuaj yeem ua tau raws li txhua qhov kev xav tau ntawm kev yuav khoom, suav nrog kev siv chav kuaj ib zaug, ntau-chaw xa khoom loj hauv chav kuaj thiab ua tiav chav kuaj tag nrho-kab hauv nruab nrab kev yuav khoom. Lub tshuab ua tiav yog nruab nrog cov khoom siv tau zoo thiab cov txheej txheem ua haujlwm SOP tag nrho, thiab dhau 48-teev kev laus ua haujlwm tsis tu ncua ua ntej xa khoom.
Khoom Parameter (Specification)
1) Flow Rate Performance Indicators Flow range: 0.001-10.000ml/min; Flow qhov tseeb: ± 1% (2ul / min); Flow precision: 0.8% (0.1ml / min ~ 10ml / min); Nruab nrog patented self-priming check valve kom txo cov raj xa hluav taws xob thiab lav qhov kev ntsuas zoo sib xws ntawm ntau chav nyob. Cov ntaub ntawv xeem thawj tau muab los ntawm Hoobkas calibration daim ntawv qhia Tshooj 2.2 ntawm phau ntawv khoom.
2) Kev Tiv Thaiv Kev Ruaj Ntseg Max siab ua haujlwm: 6000psi, ua tau -hauv ob lub siab tsis siv neeg siab & qis tiv thaiv; Sab saum toj siab txwv qhov chaw: 0-6000psi, Hoobkas nqi 5400psi; Kev txwv qis qis qhov chaw teeb tsa: 0-6000psi, pib nres & tswb thaum siab qis dua tus nqi. Tsis muaj kev pheej hmoo ntawm lub raj tawg lossis xau nyob rau hauv kev ua haujlwm siab, haum rau kev kub siab elution ua haujlwm ntawm insulating roj nrhiav kom tau.
3) Cov Kev Pabcuam Cia & Kev Sib Txuas Kev Ua Haujlwm Ib chav tsev tuaj yeem khaws 60 txoj kev sim ywj pheej, txhua txoj kev txhawb nqa 20 ntu ntu sijhawm; Txhawb txoj kab thiab ua haujlwm gradient hom kev ua haujlwm; Nruab nrog RS232 input & outputs kev sib txuas lus ports, dual twj linkage tswj thiab centralized lab tswj ntawm ntau yam pab kiag li lawm, xeem txoj kev yuav muab luam thiab synchronized rau ntau yam twj paj nruag nrog ib tug nias.
4) Lub cev & Hluav taws xob Specifications Zuag qhia tag nrho qhov ntev: 42cm × 30cm × 20cm, ib chav tsev hnyav: 8kg; Dav -ntau yam khoom siv fais fab AC85-264V, 50/63HZ, ntsuas fais fab 80W; 3A fuse matched rau domestic 220V ua hauj lwm mob, 0.75A fuse rau txawv teb chaws 110V / 120V, tsis muaj ntxiv voltage regulator yuav tsum tau. Qhov nruab nrab ntawm lub ntiajteb txawj nqus yog rau pem hauv ntej nrog kev tiv thaiv -tipping qauv, txhawb kev ruaj khov ntau txheej txheej kom txuag tau qhov chaw kuaj lub rooj zaum.
Khoom feature
High-precision Dual-plunger Infusion System nrog cov ntaub ntawv xeem muaj zog Parallelism
Flow precision 0.8%, raug < ± 1%, ruaj khov tso zis hauv qab 6000psi siab siab nrog tsis tshua muaj twj tso kua mis pulsation; nruab nrog tsis siv neeg hnyav compressibility yam them nyiaj ua haujlwm rau offset hnyav ntim poob hauv siab.
Daim ntawv thov tus nqi: ruaj khov ntev -cov ntaub ntawv xeem rau ib chav tsev, cov ntaub ntawv kuaj furfural tuaj yeem siv ncaj qha rau kev ntsuas cov khoom siv hluav taws xob. Rau kev xa tawm loj ntawm ntau chav nyob, qhov sib txawv ntawm cov txiaj ntsig ntawm qhov ntsuas tib yam ntawm cov cuab yeej sib txawv yog qhov me me, yooj yim dhau CMA / CNAS lub chaw soj ntsuam kev sib piv thiab txo cov qauv rov ua haujlwm dua.
Flow Path Special Optimized for Power Insulating Oil Test, Tau tshaj kev lag luam -Tshwj xeeb Mobile Phase
Sib cais stainless hlau siab - cov kav dej siab thiab tshwj xeeb PEEK qis- cov kav dej siab nrog tsis siv neeg plunger flushing ntws txoj kev. Clear compatibility daim ntawv teev cov furfural eluent zam pipeline corrosion, embrittlement thiab to.
Daim Ntawv Thov Tus Nqi: Tus nqi hnav ntawm cov raj xa dej thiab cov khoom sib khi txo los ntawm 30% thaum lub sij hawm ntev - lub sij hawm loj ntawm cov qauv roj transformer. Tsis tu ncua hloov cov kav dej fittings, txiav cov neeg ua haujlwm tu thiab siv nyiaj txiag, tsim nyog rau kev sim ua haujlwm niaj hnub ua haujlwm ntawm lub chaw soj nstuam.
Loj -Kev Pabcuam Cia + Ntau-Txoj Kev Sib Txuas Sib Txuas rau Kev Tswj Xyuas Txheej Txheem
Ib chav tsev khaws 60 gradient xeem txoj kev nrog 20 lub sij hawm ntu rau txhua txoj kev; bidirectional RS232 kev sib txuas lus chaw nres nkoj txhawb nqa ntau -pump linkage thiab synchronous program copy.
Daim Ntawv Thov Tus Nqi: Ntau txoj kev ntsuas roj insulating tuaj yeem khaws cia rau hauv ib chav tsev thiab rov qab los ntawm ib qho nias yam tsis tas yuav rov qab teeb tsa. Rau kev yuav khoom loj ntawm ntau chav nyob, kev lag luam tus qauv furfural kuaj cov kev pabcuam tuaj yeem tuaj yeem sib txawv nrog kev tswj hwm hauv nruab nrab, txo tus txiv neej- teev ntawm kev cob qhia cov neeg ua haujlwm thiab cov khoom siv debugging.
Ua kom tiav Multi- txheej Kev Tiv Thaiv Kev Nyab Xeeb, Lub Rooj Sib Tham Yuav Tsum Saib Xyuas Kev Nyab Xeeb Kev Nyab Xeeb ntawm Lub Zog Hluav Taws Xob
(Complete Original Anti-static & High-pressure Protection System): Puv tshuab grounding anti-static design, pressure interlock stop, circuit overload fuse protection, ventilation & explosion-proof matching design. Tag nrho cov txheej txheem kev nyab xeeb tau sau tseg hauv cov khoom siv phau ntawv.
Daim Ntawv Thov Tus Nqi: Cov cuab yeej ua raws li cov qauv kev lees paub kev nyab xeeb ntawm lub chaw kuaj hluav taws xob. Tsis muaj cov khoom siv tiv thaiv ntxiv uas xav tau rau kev xa khoom ib zaug lossis batch khoom, tshem tawm cov kev phom sij zais cia xws li hluav taws kub zoo li qub ntawm cov kuab tshuaj organic, siab - cov kua xau thiab hluav taws xob xau, dhau qhov chaw soj ntsuam kev nyab xeeb ib zaug.
Modular Standardized Accessory System nrog ruaj khov puv - voj voog khoom
Tag nrho cov twj tso kua mis lub taub hau, cov kav dej thiab cov khoom hnav tau koom ua ke thawj tus lej. Lub Hoobkas nruab nrog cov khoom siv tsis siv neeg cov kab ntau lawm thiab ntsug warehouse nrog xyoo - cov khoom lag luam ib puag ncig. Txhua lub tshuab ua tiav dhau 48-teev tsis muaj kev cuam tshuam lub siab & ntws kev laus nrog kev ywj pheej ntawm lub Hoobkas kev ua haujlwm daim ntawv tshaj tawm txuas nrog.
Daim Ntawv Thov Tus Nqi: Rau kev sib faib ib zaug -unit purchase, hnav cov khoom tuaj yeem xa tuaj sai sai hauv ib thooj tom qab. Cov neeg siv khoom loj tuaj yeem kos npe rau daim ntawv cog lus muab khoom siv txhua xyoo yam tsis muaj kev pheej hmoo ntawm cov khoom siv tawm - ntawm - Tshuag. Tag nrho cov khoom xa tawm tuaj yeem ua tau zoo ib yam tsis muaj qhov sib txawv ntawm tus kheej, tsis muaj kev kho thiab rov ua haujlwm thaum lub sijhawm xa khoom.
Khoom siv
Lub Tsev Haujlwm Saib Xyuas Kev Lag Luam Hluav Taws Xob:Petrochemical Laboratories ntawm lub xeev & lub nroog fais fab pawg, pab pawg saib xyuas substation, insulating roj kuaj cov chaw ntawm thermal/hydraulic/photovoltaic fais fab nroj tsuag, thib peb-tog soj ntsuam lab rau fais fab kev lag luam thiab txij nkawm. Tsis tu ncua kuaj cov ntsiab lus furfural hauv insulating roj ntawm transformers, transformers thiab reactors nyob rau hauv lub lag luam, txiav txim laus℃ntawm insulating paperboard, thiab teeb meem xeem ntawv qhia ua raws li lub hwj chim kev lag luam specifications.
Thib peb-Party Testing Service Enterprises:CMA/CNAS tau lees paub thib peb-chaw kuaj sim roj & roj thiab lub zog ntsuas, lees txais cov khoom loj ntawm cov qauv roj xa los ntawm daim phiaj hluav taws xob, paub txog siab -throughput thiab parallel ruaj khov nrhiav pom furfural, thiab ua tau raws li qhov yuav tsum tau muaj ntawm kev soj ntsuam kev txawj ntse thiab cov qauv piv txwv.
Ua kom tiav Equipment Integrators & General Contractors:Txhawb nqa qhov chaw nruab nrab rau kev ua haujlwm tshiab - tsim thiab rov tsim kho cov chaw kuaj hluav taws xob. Raws li lub hauv paus tseem ceeb ntawm kev ua tiav cov khoom siv ntsuas roj insulating, nws tsim cov chaw kuaj roj tag nrho ua ke nrog cov dej noo, dielectric poob thiab acid tus nqi ntsuas, thiab cov khoom siv hauv cov khoom siv rau cov phiaj xwm hluav taws xob thoob tebchaws.
Kev Tshawb Fawb Txog Kev Tshawb Fawb, Cov Tsev Kawm Ntawv Qib Siab & Cov Chaw Tshawb Xyuas Zoo:Fais fab-cov koom haum tshawb fawb, cov chaw kuaj hluav taws xob hauv tsev kawm ntawv, kev lag luam tshwj xeeb cov cuab yeej tshuaj xyuas zoo. Siv rau cov kev ntsuam xyuas kev laus ntawm cov hluav taws xob hluav taws xob, cov txheej txheem kev txhim kho thiab kev tshawb xyuas qhov tseeb ntawm txoj kev tshawb pom furfural.
Standard Complete System Configuration Scheme
- Basic Isocratic System Core Units: MEKSP-605 hnyav tus me nyuam twj tso kua mis, 7725i 6-chaw nres nkoj phau ntawv txhaj tshuaj valve, tshwj xeeb analytical chromatographic kem rau furfural, UV ntes Standard Hoobkas Accessories: Teflon hnyav inlet pipeline, 1/8 nti PEEK haum, 10μm hnyav lub cev lim dej, cov khoom pov tseg thawj zaug
- Binary High-pressure Gradient System High-pressure linkage unit nrog dual MEKSP-605 infusion twj, 7725i phau ntawv txhaj tshuaj valve (auto-sampler yeem), kem qhov cub, hauv online degasser, high-pressure tov khoom (optional volume: 5μL ~ 500μL), tshwj xeeb hauv kev kuaj pom
- Tag nrho -kab Mass Integration Solution Parallel kev sib txuas ntawm ntau lub gradient systems, RS232 centralized linkage control module, txhua xyoo kev txhawb nqa pob ntawm cov khoom siv loj, cov ntaub ntawv pabcuam rau kev kuaj layout, workstation cov ntaub ntawv nrhiav tau software
- Optional Spare Parts List (Nrog Thawj Tus Naj Npawb) Pump Head Assemblies: Micro type WK500-500-0010, Analytical type WK500-500-0011, Semi-preparative type WK500-1200, WK500-500-0013 Wear Parts: Kuaj valve WK500-500-1005, Plunger rod WK500-500-1004, Pump head sealing nplhaib WK500-500-1003 Pipeline Fittings: EK 316 stainless steel high-pressure tube flushing pipeline, ntau hom sealing ferrules, high-pressure mixing cartridge core assemblies
FAQ
Q: Koj puas yog cov chaw tsim khoom lossis lub tuam txhab lag luam?
A: Peb yog cov chaw tsim khoom ncaj qha tshwj xeeb hauv siab - cov khoom siv ntsuas hluav taws xob. Peb muaj peb tus kheej R & D pab neeg thiab cov chaw tsim khoom, uas tso cai rau peb muab lub Hoobkas - tus nqi ncaj qha thiab kev tswj xyuas nruj.
Q: Koj qhov warranty thiab tom qab - txoj cai muag khoom yog dab tsi?
A: Txhua chav tuaj nrog 12 lub hlis lav. Tom qab lub warranty tas sij hawm, peb muab kev pab cuam lub neej thiab cov kev pab them nqi kho mob.
Q: Koj puas txhawb kev sib tham lus Askiv?
A: Yog lawm, peb cov qauv qauv muaj cov keyboards Askiv, software, thiab cov neeg siv phau ntawv. Yog tias koj xav tau lwm hom lus, thov hu rau peb los kuaj xyuas qhov muaj rau kev kho.
Cim npe nrov: insulating roj furfural hplc analyzer, Tuam Tshoj insulating roj furfural hplc analyzer manufacturers, hoobkas