Peb -Phase Energy Meter Calibration Device

Xa kev nug
Peb -Phase Energy Meter Calibration Device
Paub meej
1. Built-in Class 0.05 Reference Meter, Output Stability Tsawg dua lossis sib npaug li 0.02% / 120S
2. Cov Kev Ntsuas Tag Nrho suav nrog 2-21 Order Harmonics & Voltage Dip Simulation
3. Production-line Automation Compatible, kuj txhawb Offline Standalone Verification
4. Triple Hardware Protection, Ua raws li Cov Cai Tswj Xyuas Metrological
Kev faib tawm yam khoom
Cov Khoom Siv Hluav Taws Xob Hluav Taws Xob
Share to
Hauj lwm lawm

MOEORW-WNX 90Peb -Phase Energy Meter Calibration Device

 

Khoom Taw Qhia

 

Qhov no yog ib qho kev sib koom ua ke-qhov peb-theem lub zog ntsuas ntsuas ntsuas muaj nyob rau hauv 0.05-chav kawm thiab 0.1-chav kawm qhov tseeb versions. Nws yog siv rau kev xeem yuam kev thiab kev ua haujlwm ntawm peb-theem lub zog ntsuas ntawm chav kawm 1.0 thiab hauv qab no. Txais DDS digital waveform synthesis thiab ARM embedded main controller, lub tsev ua tiav cov zis stability Tsawg dua los yog sib npaug rau 0.02% / 120S thiab waveform distortion Tsawg dua los yog sib npaug li 0.5%, ua raws li cov lus qhia txog kev ntsuas ntsuas ntsuas. Nws txhawb kev ua haujlwm tsis siv neeg txuas ntxiv mus txuas nrog cov tshuab automation nrog rau kev txheeb xyuas ib leeg yam tsis muaj PC, ua kom haum rau kev yuav khoom thiab daim ntawv thov scenarios ntawm cov nplai sib txawv.

 

Khoom Parameter (Specification)

 

1.Device chav kawm: 0.05 chav kawm, 0.1 chav kawm

2.Computer kev twb kev txuas chaw nres nkoj: RS232 kev sib txuas lus chaw nres nkoj

3.Peb -theem qhov chaw technical parameters:

Output voltage:

3 * 57.7VY 3 * 100V ∆

3 * 220V Y 3*380V ∆

Kev hloov kho ntau yam: 0-120% tsis tu ncua adjustable

Kev kho kom zoo: zoo dua 0.01%

Cov zis tam sim no: 25mA, 0.1A, 1A, 5A, 25A, 100A

Qhov kev hloov kho tsis tu ncua los ntawm 0% mus rau 120%; qhov kev hloov kho fineness yog zoo dua 0.01%.

Yam tsawg kawg nkaus tso zis tam sim no: 1mA (Qhov tseeb:<5%)

Cov zis hluav taws xob: (voltage circuit) 3 × 50VA

(Lub voj voog tam sim no) 3 × 150VA

Cov zis voltage, tam sim no, thiab lub zog ruaj khov: Tsawg dua lossis sib npaug li 0.02% / 120S

Cov zis voltage thiab tam sim no waveform distortion: Tsawg dua los yog sib npaug rau 0.5%

Peb -theem symmetry: zoo dua 120℃± 0.3 degree

Ntau zaus: 45Hz-65Hz; Kev kho qhov zoo: 0.01Hz

Kev hloov pauv theem: -180.0℃-180.0℃Kev hloov kho qhov zoo: 0.01 degree

Qhia ntsuas ntsuas: Voltmeter thiab ammeter raug yog ± 0.01%.

Qhov ntsuas ntsuas qhov tseeb yog ± 0.01 degree.

Lub ntsuas hluav taws xob muaj qhov tseeb ntawm ± 0.01Hz.

4.Ua-nyob rau hauv peb-theem standard meter technical parameters:

Voltage input

Input range (V): 40-480

Input range (V): 60, 120, 240, 480

Tshaj peev xwm (V): 600

Input load: Tsawg dua lossis sib npaug rau 0.5mA (480V)

Cov tswv yim tam sim no

Input range (A): 0.01 ~ 100

Input range (A): 100, 50, 25, 10, 5, 2.5, 1, 0.5, 0.25, 0.1, 0.05, 0.025

Muaj peev xwm tshaj (A): 150

Qhov tseeb

Qhov tseeb: 0.05 (0.1A ~ 120A)

Lub zog ntsuas qhov tseeb

Lub zog ntsuas qhov tseeb: 0.05% / 0.1% (PF Ntau dua lossis sib npaug rau 0.5)

Reactive zog ntsuas qhov tseeb yog 0.1% thiab 0.2% (PF Ntau dua lossis sib npaug rau 0.5).

Qhov tseeb ntawm kev ntsuas hluav taws xob hluav taws xob

Lub zog ntsuas qhov tseeb yog 0.05% thiab 0.1% (PF Ntau dua lossis sib npaug rau 0.5).

Reactive zog ntsuas qhov tseeb yog 0.1% thiab 0.2% (PF Ntau dua lossis sib npaug rau 0.5).

5.Cov cuab yeej muaj kev tiv thaiv kev ua haujlwm: voltage luv Circuit Court tiv thaiv, tam sim no qhib Circuit Court tiv thaiv, load overload tiv thaiv; tso saib overvoltage tiv thaiv.

6.Nws tuaj yeem ua 2nd mus rau 21st harmonic tests, voltage cuam tshuam thiab poob kev xeem, thiab lub harmonic amplitude yog adjustable.

7. Fais fab mov: 230V ± 10% ~ 50Hz

8.Kev siv hluav taws xob ntau: 300VA

9. Ua haujlwm ib puag ncig: Kub 20℃± 5 degree, txheeb ze av noo tsawg dua lossis sib npaug li 85%

 

Khoom nta thiab kev siv

 

  1. Kev tswj cov zis hloov pauv ua rau muaj kev sim rau ntau hom kev ntsuas peb-theem yam tsis muaj kev hloov kho kho vajtse ntau zaus.
  2. Cov ntaub ntawv xeem cov ntaub ntawv nyoos tuaj yeem siv rau kev xeem ntawv thiab xa mus rau kev kuaj ntsuas ntsuas.
  3. Ntau yam kev sib txuas lus interfaces tso cai rau kev sib txuas nrog cov ntaub ntawv pov thawj sab nraud thiab kev tswj hwm cov kab ntau lawm, txhawb nqa cov ntaub ntawv xa tawm thiab cov cuab yeej firmware upgrade.
  4. Cov teeb liab sib xyaw ua ke zoo heev thiab siv cov ntsuas ntsuas ntsuas tshem tawm cov khoom siv ntsuas ntsuas ntxiv. Cov ntaub ntawv xeem tuaj yeem khaws cia hauv zos thiab khaws cia ntawm USB flash drive.
  5. Kev tiv thaiv ntau txheej kho vajtse txo cov kev pheej hmoo tshwm sim los ntawm kev ua haujlwm tsis raug thiab kev ua haujlwm hloov pauv.
  6. Ua kom tiav cov ntawv pov thawj yooj yim tuaj yeem ua yam tsis muaj PC. Nws yog qhov tsim nyog rau kev soj ntsuam tsis tu ncua mus sij hawm ntev nrog rau cov chaw sim nrog cov chaw ua haujlwm tsawg.

 

Kev tsim tawm nthuav dav

 

Three-Phase Energy Meter Calibration Device
Kev tsim tawm nthuav dav

Lub zog ntsuas hluav taws xob: Cov khoom lag luam tiav hauv lub Hoobkas kev tshuaj xyuas zoo, kev tshawb xyuas ntau ntxiv ntawm cov kab ntau lawm

Kev lag luam hluav taws xob: Kev txheeb xyuas cov dej num rau cov chaw ntsuas hluav taws xob thiab cov tub ceev xwm muab hluav taws xob hauv txhua qib

Cov koom haum kuaj thib peb: ntsuas hom ntsuas thiab ntsuas kev ua haujlwm hauv cov chaw kuaj ntsuas ntsuas

Kev Tshawb Fawb Txog Kev Tshawb Fawb & Kev Kawm: Kev Tshawb Fawb Txog Hluav Taws Xob Hluav Taws Xob rau cov chaw tshawb fawb thiab cov tsev kawm qib siab

Grassroots entities: Routine zog-meter calibration rau cov koom haum kuaj me me thiab chaw ua haujlwm-tswj

 

 

 

Hardware & Expansion Configuration

 

  • Waveform Power Amplifier Unit: 36000-point DDS waveform interpolation, 300 KHz PWM digital fais fab amplifier nrog efficiency siab tshaj 90%. Kev tswj qhov kub thiab txias ua rau muaj qhov tseeb qis qis thaum lub sijhawm ua haujlwm ntev. Lub ntsuas kub tsis tu ncua siv lead ua oscillator yog nruab rau kev ntsuas lub sijhawm ntsuas qhov yuam kev.
  • Tib neeg-tshuab Structure: 7-nti kov npo, aluminium alloy txee, detachable meter fixture. Tag nrho cov haujlwm pov thawj hauv paus tau teeb tsa ua ntej uas tsis tas yuav ua kom muaj zog ntxiv.
  • Optional Modules: 2-21 xaj kev sib haum xeeb superposition, voltage dip & interruption simulation, 485 meter kev sib txuas lus xeem.
  • Cov yam ntxwv ntawm tus qauv: Modular sib dhos. Cov chav nyob hauv ib pawg txais yuav cov khoom sib koom ua ke rau cov khoom sib hloov tau. Txoj haujlwm logic tuaj yeem hloov kho rau kev sib txuas ntawm cov kab ntau lawm. Cov cuab yeej npaj txhij-rau-siv tom qab lub hwj chim qhib. Cov lus tsis raug yog tso tawm ntawm qhov screen rau kev kuaj tus kheej ntawm qhov ua tsis tiav.

 

FAQ

Q: Koj puas yog cov chaw tsim khoom lossis lub tuam txhab lag luam?

Peb yog cov chaw tsim khoom ncaj qha tshwj xeeb hauv siab - cov khoom siv ntsuas hluav taws xob. Peb muaj peb tus kheej R & D pab neeg thiab cov chaw tsim khoom, uas tso cai rau peb muab lub Hoobkas - tus nqi ncaj qha thiab kev tswj xyuas nruj.

Q: Koj qhov warranty thiab tom qab - txoj cai muag khoom yog dab tsi?

A: Txhua chav tuaj nrog 12 lub hlis lav. Tom qab lub warranty tas sij hawm, peb muab kev pab txhawb nqa lub neej thiab kev pab them nqi kho mob.

Q: Koj puas txhawb kev sib tham lus Askiv?

Yog lawm, peb cov qauv qauv muaj cov keyboards Askiv, software, thiab cov neeg siv phau ntawv. Yog tias koj xav tau lwm hom lus, thov hu rau peb los kuaj xyuas qhov muaj rau kev kho.

 

Cim npe nrov: peb-theem zog meter calibration ntaus ntawv, Tuam Tshoj peb-theem zog meter calibration ntaus ntawv manufacturers, hoobkas

Xa kev nug