Peb -Phase Electric Zog Meter Calibration Bench
Khoom Taw Qhia
MEDT-WP/3M Peb-Phase Multifunctional Energy Meter Calibration Bench ntiav cov thev naus laus zis xws li digital electronics, analog circuits, thiab ib leeg -chip microcomputers. Lub zog hluav taws xob no siv MCU microcontroller ua nws cov tub ntxhais kawm, suav nrog cov kev sib txuas digital, digital zaus hloov kho, digital amplitude modulation, digital theem hloov, thiab cov txheej txheem pulse width modulation. Nws kov yeej qhov tsis txaus ntawm cov khoom siv hluav taws xob ib txwm muaj- xws li kev ua haujlwm qis, kev tsim hluav taws xob ntau dhau, thiab kev cia siab tsis zoo- Nws cov yam ntxwv tseem ceeb tshaj plaws yog kev ua haujlwm siab thiab cov yam ntxwv ntawm kev thauj khoom zoo, ua rau nws yog qhov zoo tshaj plaws tom ntej - tiam multi- txoj hauj lwm lub zog ntsuas calibration ntaus ntawv.
Qhov ntsuas hluav taws xob no tsim nyog rau kev txheeb xyuas hluav taws xob thiab hluav taws xob hluav taws xob peb -theem multifunction meters, multi-rate zog ntsuas, prepaid zog ntsuas, thiab standard zog ntsuas. Nws tuaj yeem ntsuas cov ntsuas hluav taws xob reactive raws li ntau yam kev ntsuas, suav nrog peb-theem plaub-hlau hla-theem reactive, peb-theem plaub-wire sinusoidal reactive, peb-theem peb-wire sinusoidal reactive, thiab peb{11}sewire{10} 60-degree theem-hloov reactive meters.
Lub ntsuas hluav taws xob no tuaj yeem ua haujlwm siv nws tus kheej lub vaj huam sib luag keyboard lossis ntawm lub khoos phis tawj software nrog rau daim ntawv thov. Ob txoj kev yog yooj yim thiab ncaj.
Khoom Parameter (Specification)
|
Fais fab mov |
220V ± 10%, 50Hz / 60Hz; |
|
Kev siv hluav taws xob siab tshaj plaws |
1800 VA; |
|
1. Phantom Load Power Source Specifications |
◆ Tso zis Voltage; 3x30V(AC) - 3x380V(AC); Kev daws teeb meem; 0.01% ntawm qhov tam sim no; ◆ Tso zis tam sim no; 0.1A (AC) - 100A (AC); Kev daws teeb meem; 0.01% ntawm qhov tam sim no; ◆ Phase ua haujlwm ntau yam; 0-360 degree; Kev daws teeb meem; 0.1 degree; Voltage / Tam sim no tso zis zaus; 45Hz-65Hz; Kev daws teeb meem; 0.01 Hz; |
|
◆ Waveform distortion thaum lub sij hawm sine wave tso zis |
Voltage, Tam sim no <0.5%; |
|
◆ Voltage, tam sim no, thiab lub zog ruaj khov ntawm lub zog hluav taws xob thaum lub sij hawm sine yoj tawm |
<0.1% (180s); |
|
◆ Load yam ntxwv |
Muaj peev xwm tsav cov loads resistive, inductive loads, thiab capacitive loads (tsawg dua 4uF); |
|
Tso zis waveform |
Muaj peev xwm tsim sine waves; Muaj peev xwm ua kom muaj kev sib haum xeeb thib 2 txog 21, nrog rau tag nrho cov kev sib txawv ntawm qhov sib txawv <40%; Muaj peev xwm tsim qhov sib txawv -numbered harmonics; Muaj peev xwm tsim cov sub- harmonics; |
|
Tso zis muaj peev xwm |
Voltage qhov siab tshaj 160VA; Tam sim no qhov chaw siab tshaj 650VA. |
|
2. Cov Qauv Ntsuas Hluav Taws Xob Cov Lus Qhia |
|
|
◆ Qauv |
HDS322-02 Multifunctional Standard Meter; |
|
◆ Fais fab mov |
220V / 240V ± 10%, 50Hz; Kev siv hluav taws xob siab tshaj plaws; 30VA; |
|
◆ Kev ntsuas kev ua haujlwm |
Voltage Measurement Range; 40V (AC) - 480V (AC); (Internal ranges; 60/120/240/480) |
|
◆ Kev ntsuas tam sim no |
0.001A(AC) - 100A(AC); (Internal ranges; 0.02/0.05/0.1/0.2/0.5/1/2/5/10/20/50/100) |
|
◆ Chav Kawm raug |
0.05 lossis 0.1; |
|
Lub zog ntsuas qhov tseeb |
0.05% 0.1% (PF>0.5); |
|
Reactive zog ntsuas qhov tseeb |
0.1% 0.2% (PF>0.5); |
|
◆Sov-Lub Sij Hawm |
30 feeb; |
|
◆ Kev ua haujlwm ib puag ncig |
Kub +5℃rau +40℃; |
|
◆ Tus txheeb ze humidity |
<85%; |
|
◆ Tsis muaj corrosive gases. |
|
Khoom feature thiab daim ntawv thov
1) Siv pulse width modulation power amplification technology (tseem hu ua digital power amplification technology), muab kev ruaj ntseg thiab kev ntseeg siab nrog lub hwj chim amplifier conversion efficiency tshaj 90%;
2) Software- tswj pib / nres rau cov zis voltage thiab tam sim no;
3) Tsis siv neeg hloov pauv ntawm cov zis tam sim no; tsis siv neeg tshawb pom, tswb, thiab kev tiv thaiv raws li qhov voltage lossis tam sim no tso zis tsis raug;
4) Kev ruaj ntseg zoo, muaj kev ntseeg siab, thiab cov yam ntxwv zoo thauj khoom;
5) Lub zog tso zis ntau: voltage tso zis ntau yam (200VA-1000VA), tam sim no tso zis ntau yam (200VA-1000VA);
6) Muaj peev xwm ntawm ib txhij calibrating hluav taws xob ntsuas nrog zoo tib yam specifications tab sis sib txawv zog tas li;
7) Cov yam ntxwv tsis siv neeg tshawb nrhiav kev ua haujlwm (ua kom yooj yim nkag thiab pib- nce kev xeem) thiab xaiv qhov kho qhov muag lub taub hau sau ua haujlwm txhawm rau txhim kho kev ua haujlwm zoo;
8) Txheem RS485 kev sib txuas lus sib txuas ua ke rau hauv chav tsev; thaum ua ke nrog software, nws tuaj yeem kuaj qhov chaw sib txuas lus ntawm cov ntsuas hluav taws xob (cov neeg siv kuj tseem tuaj yeem ua qhov kev txhim kho theem nrab ntawm lwm cov haujlwm raws li peb lub tuam txhab phau ntawv qhia kev txhim kho theem nrab kom tau raws li lawv cov kev ntsuas hluav taws xob tshwj xeeb);
9) Nruab nrog PC ua haujlwm thiab tswj software hauv Windows; calibration tau txais kev cawmdim, queried, thiab luam;
10) Muab cov ntaub ntawv qhib database rau network- theem tswj cov ntaub ntawv yuam kev, ua kom nkag tau los ntawm qib siab dua - theem kev tswj hwm;
11) Cov qauv zoo meej, tsim qauv tsim nyog, zoo nkauj zoo nkauj, thiab hloov tau yooj yim. Muaj nyob rau hauv ob hom sib txawv: kev sib xyaw thiab sib cais- hom qauv.
Kev tsim tawm cov ntsiab lus
Haum rau kev ntsuas hluav taws xob, hluav taws xob ntsuas hluav taws xob, thiab cov chaw soj ntsuam zoo, cov cuab yeej no yog siv los ntsuas ntau hom hluav taws xob / hluav taws xob peb-theem multifunction meters, multi-tariff meters, prepaid meters, thiab lwm yam hluav taws xob ntsuas. Nws tuaj yeem ua qhov kev ntsuam xyuas rau kev nkag mus, pib, yuam kev, kev sib haum xeeb, thiab lwm yam. Txhawb kev ntsuas ib txhij ntawm ntau txoj haujlwm 'meter', nws yog qhov tsim nyog rau cov xwm txheej xws li kuaj xyuas, kuaj xyuas lub Hoobkas, thiab kev ntsuas qhov ntsuas.
Lub Tuam Txhab Txuj Ci
Cim npe nrov: Tuam Tshoj 'meter' calibration xeem lub rooj zaum, Tuam Tshoj 'meter' calibration xeem bench manufacturers, hoobkas