Phase Detector

Xa kev nug
Phase Detector
Paub meej
ME-WTAG6000C High-Voltage Wireless Phase Tester yog qhov tsim nyog rau kev txheeb xyuas theem ntawm AC cov kab sib txuas thiab cov khoom siv nyob. Nws suav nrog cov khoom siv xws li lub tshuab xa hluav taws xob thiab cov neeg txais xov tooj, muaj kev sib txuas lus wireless thiab ntsuas qhov tseeb. Cov cuab yeej muab lub suab thiab cov lus ceeb toom. Cov cai tswj kev nyab xeeb yuav tsum tau ua raws, thiab kev saib xyuas kom raug.
Kev faib tawm yam khoom
Cable Fault Locating System
Share to
Hauj lwm lawm

High-Voltage Wireless Phase Comparator

 

Khoom Taw Qhia

 

ME-WTAG6000C High-Voltage Wireless Phase Comparator (tom qab no hu ua "tus ntsuas") yog tsim los rau kev txheeb xyuas theem thaum lub sijhawm sib txuas ntawm ob lub siab -voltage kab lossis hauv lub nplhaib sib txuas. Cov cuab yeej tsim nyog rau kev txheeb xyuas theem ntawm AC cov kab sib kis xws li 5V txog 500kV thiab theem nrab nyob - kab qhia, thaum tseem muaj nyob -kab nrhiav kev ua haujlwm.

Ua haujlwm siv thev naus laus zis sib kis tau zoo, cov cuab yeej ua kom muaj kev nyab xeeb thiab txhim khu kev qha nrog cov neeg siv - ua haujlwm zoo, kov yeej ntau qhov kev txwv ntawm cov kab sib piv. Tsis tas li ntawd, cov cuab yeej txhawb nqa kev txhim kho theem ua ntu zus kom pom thiab muaj peev xwm txheeb xyuas qhov chaw nyob deb.

 

Khoom Parameter (Specification)

 

1. Phase sib txawv raug

Kev ua yuam kev tsawg dua lossis sib npaug li 5℃.

2. Muaj qhov raug

± 0.1Hz

3. Hla -voltage ntsuas ntau yam

5V rau 500kV.

4. Cov kab siab tshaj plaws - ntawm - pom kev sib kis deb ntawm transmitter thiab receiver host

kwv yees li 100 meters.

5. Tiag - lub suab ceeb toom rau kev ntsuas ntsuas thiab cov kauj ruam ua haujlwm.

6. 3.2-inch xim npo ib txhij qhia cov theem sib txawv, zaus, vector daim duab, thiab theem / tsis yog- theem tshwm sim rau ob kab.

7. Auto- kaw tom qab 1 teev tsis ua haujlwm.

8. Transmitter thiab receiver host ob qho tib si feature ua -nyob rau hauv rechargeable lithium roj teeb nrog ib tug 5V charger nrog.

9. Lub receiver unit suav nrog 18650 lithium roj teeb nrog lub peev xwm ntawm 2600mAh. Lub tsev transmitter suav nrog 10440 lithium roj teeb nrog lub peev xwm ntawm 340mAh (qhov muaj peev xwm tiag tiag yuav txawv vim cov roj teeb sib txawv).

10. Cov dej ntws tawm thaum lub sij hawm siab - qhov ntsuas hluav taws xob yog

<10μA.

11. Transmitter kev khiav hauj lwm lub zog noj<0.1W; receiver host operating power consumption 

<0.3W.

12. Kev ua haujlwm ib puag ncig

-35℃rau +45 degree, av noo tsawg dua lossis sib npaug li 95%RH.

13. Tag nrho qhov hnyav

Kwv yees li 7KG.

14. Ntsuas ntim qhov ntev

112cm (L) × 26cm (W) × 11cm (H).

 

Khoom feature thiab daim ntawv thov

 

I. Kev ua haujlwm zoo thiab siv dav dav

Kev txheeb xyuas theem dhau AC cov kab sib txuas ntawm 5V txog 500kV yog ua tau los ntawm kev siv hluav taws xob ntau. suav nrog nyob - kab kev tshawb nrhiav kab thiab ib txhij muaj kev txheeb xyuas theem rau theem nrab nyob - kab qhia.
tso cai rau kev ua haujlwm hloov tshiab thiab tuaj yeem nthuav dav nrog lub peev xwm rau kev txheeb xyuas cov theem deb thiab kev tshawb nrhiav theem los txhawb ntau yam kev thov.


II. Kev ua tau zoo heev thiab kev ntsuas raug

Kev ntseeg tau ntawm cov kev tshawb fawb pom tau tias ua tau raws li National Standard Class A (nrog ± 30℃raws li theem kev sib txawv) yog muab los ntawm theem siab qhov sib txawv qhov tseeb nrog qhov yuam kev tsawg dua lossis sib npaug li 5℃thiab qhov tseeb ntawm ± 0.1Hz.
Tsawg leakage tam sim no (<10μA) while measuring at a high voltage. Low energy consumption and improved safety are ensured by transmitter operating power consumption of less than 0.1W and receiver host operating power consumption of less than 0.3W.

 

III. Yooj yim-rau- siv kev ua haujlwm thiab kev paub

Txoj kab siab tshaj plaws - ntawm - pom qhov deb ntawm ib ncig ntawm 100 meters ntawm transmitter thiab receiver yog ua tau los ntawm wireless kis technology, uas tshem tawm cov kev txwv cable rau kev ua haujlwm yooj yim.
muab cov lus qhia ncaj nraim los ntawm kev qhia cov theem sib txawv, zaus, cov duab kos duab, thiab theem- sib piv cov txiaj ntsig rau ob kab ntawm 3.2- nti xim zaub. txhawb kev txiav txim siab sai los ntawm kev txhawb nqa lub suab rau cov txheej txheem kev ua haujlwm thiab ntsuas cov txiaj ntsig.
muaj lub tshuab kaw tsis siv neeg kom txuag tau lub zog tom qab ib teev ntawm kev tsis ua haujlwm. Lub buzzer ua haujlwm raws li qhov muaj sia nyob - kab ceeb toom thiab lub roj teeb qhia txog xwm txheej thaum lub tshuab xa tawm tuaj rau hauv kev sib cuag nrog lub siab -voltage kab (peb lub beeps qhia tag nrho cov nqi, ob lub beeps qhia lub zog siv tau, thiab nruam beeping qhia tias qis zog).

 

IV. Kev cia siab thiab kev nyab xeeb nrog txhua yam -Txog Kev Tiv Thaiv

Nws yog tsim los ntawm cov ntaub ntawv uas ua tau raws li IEC / 1C78 qhov yuav tsum tau muaj thiab muaj 5-meter tus qauv insulated pas nrig (tsim rau Tsawg dua lossis sib npaug rau 500kV voltage). Raws li ntau lub teb chaws thiab lub zog kev lag luam kev cai, nws muaj kev cuam tshuam tsis kam, noo noo tsis kam, thiab high-voltage endurance.
piav qhia siab -voltage testing cov txheej txheem kev nyab xeeb hauv kev nthuav dav, suav nrog txoj hauj lwm ntawm cov pas nrig insulated kom txo tau qhov txaus ntshai ntawm hluav taws xob poob siab. A 2-megohm internal resistor hauv kev kuaj tus kheej ua rau tshem tawm txoj kev pheej hmoo ntawm hluav taws xob poob siab thaum tib neeg tuaj yeem kov cov kab nuv ntses.
Dedicated rechargeable lithium roj teeb nrog 5V charger yog siv los ntawm ob qho tib si transmitter thiab receiver, tshem tawm qhov kev pheej hmoo ntawm kev hloov roj teeb txaus ntshai.

 

V. Kev tu yooj yim thiab cov qauv tsim nyog

Ob lub transmitters, ib lub receiver unit, ib tug insulated pas nrig, ib tug charger, thiab ib tug accessories yog tag nrho cov nyob rau hauv lub meej Cheebtsam faib. Rau ntau qhov xwm txheej ntawm kev teeb tsa, cov khoom xa tawm tau txuas nrog telescopic insulated rods ntawm qhov mounting.
Qhov tsuas yog xav tau kev saib xyuas yog them tag nrho rau lub sijhawm ntev - khaws cia thiab them rov qab txhua hli. Tshem tawm ntawm thaj chaw uas muaj plua plav, kub, lossis av noo. Txhawm rau kom muaj kev nyab xeeb ntawm kev ua haujlwm, ua qhov ntsuas qhov ntsuas hluav taws xob ntawm cov ncej insulated ua ntej siv thiab txhua xyoo tom qab ntawd.

 

VI. Saj zawg zog nyob rau hauv ntau daim phiaj-Txoj kev sib txuas

Ob lub tshuab hluav taws xob quasi-synchronization (tsis tshua muaj kev cuam tshuam, tsim nyog rau lub tshuab hluav taws xob loj) thiab tus kheej -synchronization (ceev ceev, tsim nyog rau me me hydropower) kab hluav taws xob- cov tswv yim sib txuas tau txais kev txhawb nqa los ntawm kev sib piv cov kev tshawb pom, txaus siab rau ntau yam kev siv hluav taws xob sib xyaw ua ke.

 

Kev tsim tawm cov ntsiab lus

 

Core Function:Kev txheeb xyuas theem rau ob lub siab- cov kab hluav taws xob thaum lub sij hawm sib txuas kab sib txuas / lub nplhaib sib koom ua ke, kom ntseeg tau tias theem sib xws.

Voltage Adaptability:5V–500kV AC kis tau tus mob kab thiab theem nrab nyob - kab qhia, txhawb nqa nyob - kab tshawb pom.

Application Scenario:Fais fab cog kab sib txuas, kev ua haujlwm substation thiab kev saib xyuas, siab -voltage kab kev tsim kho / tu, industrial high-voltage equipment commissioning.

Extensions & Notes:Upgradeable phase sequence/remote phase verification functionality; longer insulated poles required for voltages >500 kV; phau ntawv pov thawj ntawm cov kab tseem ceeb uas yuav tsum tau muaj thaum cov zaub nyob qhia txog theem kev pov thawj tsis txaus ntseeg.

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

1) Puas yog METAG6000C Siab-Voltage Wireless Phase Tester txhawb kev hloov kho dua tshiab? Dab tsi ntxiv nta yuav nthuav tau?

Teb: Cov cuab yeej no txhawb kev txhim kho kev ua haujlwm, ua kom muaj kev nthuav dav ntawm theem kev tshawb pom thiab cov chaw taws teeb txheeb xyuas cov peev txheej kom haum rau ntau yam ntawm cov ntawv thov scenarios.

2) Dab tsi yog qhov tseem ceeb ntawm METAG6000C High-Voltage Wireless Phase Comparator?

Teb: Cov cuab yeej feem ntau muaj ob lub transmitters thiab ib lub receiver host, ntxiv los ntawm cov khoom siv xws li cov pas nrig insulated, charger, thiab cov ntaub ntawv khoom siv. Cov transmitters ntes kab energization raws li txoj cai, ntsuas theem kaum sab xis thiab zaus, thaum lub receiver host tau txais cov ntaub ntawv los xam theem sib txawv thiab txiav txim theem sib txuam / kev tsis sib haum xeeb.

3) Dab tsi yog qhov tseem ceeb ntawm kev nyab xeeb thaum siv METAG6000C High-Voltage Wireless Phase Tester?

Teb: Kev sim teb yuav tsum ua raws li kev siv hluav taws xob siab -voltage kev nyab xeeb cov qauv ntsuas. Thaum lub sij hawm ntsuas theem, tes txoj hauj lwm yuav tsum tsis txhob tshaj lub insulated ncej kov. Transmitters xav tau cov roj teeb lithium rechargeable; txwv tsis pub lwm hom roj teeb. Xaiv cov insulated ncej ntawm qhov ntev tsim nyog rau kev ntsuas kab ntawm cov theem voltage sib xws.

 

Cim npe nrov: Phase Detector Manufacturers thiab lwm tus neeg - Tuam Tshoj Phase Detectors

Xa kev nug