Cable thiab Pipe Locator

Xa kev nug
Cable thiab Pipe Locator
Paub meej
ME -W9005: Kev ua haujlwm tiav! Pipeline routing, kev txheeb xyuas cable, thiab kev kuaj xyuas qhov yuam kev - txhua tus tuav nrog ib qho nias. Ntau hom teeb liab hloov mus rau ntau yam xwm txheej, ua kom cov neeg siv- ua haujlwm zoo thiab ntsuas qhov tob. Tsim cov ntawv ceeb toom tam sim ntawm lub app, ua rau muaj txiaj ntsig zoo rau kev tshuaj xyuas cov kav dej thiab kev saib xyuas kom zoo.
Kev faib tawm yam khoom
Cable Fault Locating System
Share to
Hauj lwm lawm

Comprehensive Pipeline thiab Cable Detection Instrument

 

Khoom Taw Qhia

 

ME-W9005 Comprehensive Pipeline thiab Cable Locator muaj kev ua haujlwm dav dav, ua kom pom txoj hauv kev hauv lub raj xa dej, kev txheeb xyuas kab hluav taws xob, qhov chaw txhaum hauv av, thiab GPS daim ntawv qhia. Cov cuab yeej suav nrog cov khoom tseem ceeb xws li transmitters thiab receivers, txhawb nqa ntau yam teeb liab tso tawm txoj kev suav nrog kev sib txuas ncaj qha thiab clamp txuas. Nws nta muaj zog tiv thaiv - muaj peev xwm cuam tshuam thiab muab qhov tseeb qhov chaw thiab ntsuas qhov tob. Tau tshaj Android thiab HarmonyOS systems, nws tsim cov ntawv ceeb toom los ntawm nws cov app siab. Qhov zoo tshaj plaws rau kev tshuaj xyuas cov kav dej thiab kev saib xyuas hauv nroog, lub zog, thiab kev sib txuas lus kev lag luam, nws muab cov neeg siv khoom siv - kev ua haujlwm zoo nrog kev nyab xeeb.

 

Khoom Parameter (Specification)

 

Yeem nta

Tshawb nrhiav App

Cov app no ​​​​, siv ua ke nrog lub receiver, enables GPS pipeline mapping, tso cai rau kev ntsuas qhov chaw, tswj, thiab saib cov kav dej hauv av hauv thaj chaw thaj chaw, qhov tob, thiab lwm yam ntaub ntawv. Nws kuj muab kev pabcuam huab rau cov ntaub ntawv khaws cia, thaub qab, thiab hloov pauv.

Qhov chaw txhaum

Thaum siv nrog A-thav duab, nws tuaj yeem ua kom pom tseeb qhov chaw ntawm cable grounding faults.

R TK

Siv cov cuab yeej RTK , centimeter - theem siab - qhov tseeb qhov chaw tau tiav. Ib qho tshwj xeeb app, siv ua ke nrog cov khoom siv tes tuav, ua kom pom tseeb taw tes qhia qhov chaw ntawm cov kav dej.

 

2. Txais Specifications

Muaj nuj nqi

Pipeline nrhiav kom tau (kab qhov chaw taug qab, kev taw qhia zaub, ntsuas qhov tob, ntsuas tam sim no), kev txheeb xyuas cov kab hluav taws xob, cov kav dej hauv av txhaum qhov chaw, kav raj xa dej, kev pabcuam huab, kev sib txuas lus Bluetooth

fais fab mov

7.4V DC 3400mAh rechargeable lithium roj teeb

Txoj kev nkag

Ua-nyob rau hauv tau txais kauj, hloov tau caliper, stethoscope

Kev sib txuas lus Bluetooth

Nws txhawb Bluetooth kev sib txuas lus rau kev ntsuas ntsuas thiab kev sib txuas rau lub xov tooj ntawm tes app rau ntau yam ntaub ntawv ua.

Txais zaus

Kev tshawb nrhiav ntau zaus: 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz, 201kHz

Fais fab zaus passive nrhiav tau zaus: 50Hz, 250Hz

Xov tooj cua zaus passive nrhiav band: nruab nrab zaus yog 33kHz thiab 82kHz.

Pipeline nrhiav hom

Wide peak method, nqaim peak method, thiab valley method

Pipeline nrhiav pom

Classic positioning hom, qhia hlau cruise hom, teeb liab nkhaus hom

Pipeline nrhiav pom

Kev kuaj pom ntau

Txoj kev sib txuas ncaj qha: Feem ntau, qhov ntev ntawm lub cable tuaj yeem yog 0 txog 20 mais, feem ntau txiav txim siab los ntawm kev tiv thaiv hauv av, cable tsis kam, thiab cable faus qhov tob.

Coupling txoj kev: Feem ntau, nws muaj peev xwm ncav cuag cable ntev ntawm 0 mus rau 10 kilometers, feem ntau txiav txim los ntawm grounding kuj, cable kuj, thiab cable faus qhov tob.

Txoj kev induction: Haum rau cov cables faus ntawm qhov tob ntawm tsawg dua 2m.

Qhov tob thiab tam sim no

Tsis siv neeg nyeem cable qhov tob thiab tus nqi tam sim no

Pipeline qhov tob ntsuas

0 ~ 20m

Qhov tseeb qhov tob

Precise planar positioning raug: Txoj hauj lwm ntawm qhov chaw nruab nrab ntawm lub hom phiaj cable lossis kav dej:

± 5% (faus qhov tob 0 ~ 3m) ± 10% (faus qhov tob 3m ~ 20m)

Muaj tseeb / tsis yog lus ceeb toom

Txhawm rau tshem tawm kev cuam tshuam los ntawm cov cables nyob ze, thaum ntsuas cov cables nyob ze, qhov ntsuas ntawm cov cables nyob ze tuaj yeem paub qhov txawv raws li cov teeb liab sib txawv thiab cov theem ntawm kev ntsuas tam sim no pub rov qab los ntawm cov kab nyob ze. Thaum lub sij hawm siv cable tracing, theem dial thiab pointer kev taw qhia tau pom kom sib txawv ntawm cov kab hauv qab kev sim thiab cov kab nyob ze.

suab qhia

Zaus modulation suab uas txawv nrog lub teeb liab zog

Anti- muaj peev xwm cuam tshuam

Nrog nws qhov nqaim heev tau txais bandwidth thiab cov txheej txheem kev ua digital tshwj xeeb, nws tuaj yeem cuam tshuam lub zog zaus thiab kev sib raug zoo cuam tshuam los ntawm cov chaw ua haujlwm nyob ze thiab cov kav dej.

Sib nrug deb

Thaum siv txoj kev sib txuas thiab induction, lub transmitter yuav ua rau muaj kev cuam tshuam ntawm qhov ze. Qhov kev ncua deb ntawm qhov cuam tshuam yog cuam tshuam nrog lub zog xa mus thiab zaus. Qhov siab dua lub zog thiab ntau zaus, qhov kev cuam tshuam muaj zog dua.

Qhov tsawg kawg nkaus nyob deb ntawm tus neeg txais kev tiv thaiv kab mob cuam tshuam feem ntau yuav tsum tau txiav txim siab sim.

Pipeline nrhiav tau: Coupling txoj kev tuaj yeem paub meej tias tsis muaj kev cuam tshuam dhau 5m, induction txoj kev tshaj 20m.

Kev txheeb xyuas Cable: Siv txoj kev sib txuas, cuam tshuam -kev ua haujlwm pub dawb tuaj yeem lees paub ntawm qhov deb ntawm 2-5 meters.

Kev txheeb xyuas kab

Cov txheej txheem kev txheeb xyuas: kev txheeb xyuas ntse nrog cov calipers hloov tau, kev txheeb xyuas nrog lub stethoscope;

Tus naj npawb ntawm cov cables tuaj yeem teev tau yog 1 txog 10 .

Calibration tus nqi: Ib feem pua ​​​​ntawm cov teeb liab tau txais thiab cov teeb liab kis tau los ntawm 75% thiab 135% ntawm tus nqi calibration yog ib qho ntawm cov xwm txheej rau kev txheeb xyuas tau zoo;

Directionality: Lub transmitting clamp, txais clamp, thiab loaded teeb liab yuav tsum tau ua raws li cov kev taw qhia; qhov no yog ib qho ntawm cov xwm txheej rau kev txheeb xyuas kom tiav.

Kev txheeb xyuas kab

Kev kuaj pom ntau

Txoj kev sib txuas ncaj qha: tuaj yeem txheeb xyuas cov teeb liab nrog lub voj tsis kam ntawm 0Ω mus rau 8kΩ (feem ntau siv tau rau cable ntev ntawm 0 txog 20 mais, feem ntau txiav txim siab los ntawm kev tiv thaiv hauv av thiab cable tsis kam).

Txoj kev sib txuas: tuaj yeem txheeb xyuas cov teeb liab nrog lub voj tsis kam ntawm 0Ω txog 1 kΩ; (feem ntau siv tau rau cable ntev ntawm 0 mus rau 6 kilometers, feem ntau txiav txim siab los ntawm grounding resistance thiab cable resistance)

LED hmo ntuj teeb pom kev zoo

Lub receiver muaj lub teeb nyem LED ua haujlwm.

siv lead ua kua

3.5-nti xim LCD npo

qhov loj

290 mm (ntev) × 128 mm (dav) × 700 mm (qhov siab)

zoo

Kwv yees li 1.90 kg

charger

DC 8.4V 1A

Teeb pom kev zoo

1 W max

Kev sib txuas interface

1 mini - B USB chaw nres nkoj (rau kev hloov kho firmware)

1 * DC charging chaw nres nkoj

1 * Flexible clamp txuas qhov (socket).

Flexible Current Clamp

Kwv yees li 620mm nyob rau hauv ntev thiab 8mm inch.

Coil puab txoj kab uas hla

φ200mm (qhov loj dua tuaj yeem ua raws li qhov kev thov)

stethoscope loj

Kwv yees li 111mm x 60mm x 27mm (stethoscope yeem)

Lead ntev

Stethoscope lead ntev: Kwv yees li 3m

Ua haujlwm kub thiab av noo

-10℃-40 degree; qis dua 80% Rh

Cia kub thiab av noo

- 10℃~ 50℃; Tsawg dua los yog sib npaug rau 95% RH, tsis muaj condensation

Siab tsis kam

AC 37 00V/rms (nruab nrab ntawm sab saum toj thiab hauv qab kawg ntawm lub casing)

Tsim nyog rau kev tswj hwm kev nyab xeeb

IEC 61010-1 CAT III 600V, IEC61010-031, IEC61326, Kev Ua Phem 2

 

3. Transmitter Specifications

Muaj nuj nqi

Ntau zaus teeb liab txoj kev kis tau tus mob

fais fab mov

11.1V DC 12800mAh rechargeable lithium roj teeb

Txoj kev tso zis

Txoj kev sib txuas ncaj qha, caliper coupling method, inductive method

Tso zis zaus

577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz, 201kHz

Tso zis zog

10W max, 10 qib kho tau

impedance

Siab tsis siv neeg tiag tiag -lub sij hawm impedance txuam thiab kev tiv thaiv muaj nuj nqi

Direct- txuas cov zis hluav taws xob

150V max

Kev tiv thaiv Circuit Court

Nws muaj kev tiv thaiv overload thiab luv luv Circuit Court

siv lead ua kua

5.6-nti LCD xim npo

Instrument Dimensions

320mm (ntev) × 275mm (dav) × 145mm (qhov siab)

zoo

Lub transmitter hnyav li ntawm 3.85 kg; Lub launch clamp hnyav kwv yees li 1.18 kg.

charger

DC 12.6V 2A

Launcher loj

Qhov Loj (L x W x D): 297 mm × 194 mm × 39 mm

Launch clamp puab txoj kab uas hla

φ150 hli

Launch clamp ntev

3m

Kuaj kab

Liab xeem kab 3m, dub xeem kab 3m

Kev sib txuas interface

1 * Hom - B USB interface (rau kev hloov kho firmware)

1 * DC charging chaw nres nkoj

1 * Teeb liab Transmitter Clamp Connector

2* Direct-txuas kev kuaj cable interfaces

Siab tsis kam

Lub transmitter txais ib qho kev sib xyaw ua ke, tsim lub thawv tsim, thiab lub thawv tuaj yeem tiv taus qhov siab ntawm kwv yees li 200 kg.

Siab tsis kam

AC 3700V / rms (nruab nrab ntawm sab saum toj thiab hauv qab ntawm lub thawv ntsuas)

Electromagnetic zog

IEC 61326 (EMC)

Tsim nyog rau kev tswj hwm kev nyab xeeb

IEC 61010-1 (CAT III 300V, CAT IV 150V, cov pa phem theem 2)

 

Khoom feature thiab daim ntawv thov

 

1. Ntau hom kev kuaj pom: Classic Positioning Mode, Conductor Cruise Mode, Signal Curve Mode.

2. Classic Positioning Hom: Qhia lub compass, kev taw qhia, thiab teeb liab amplitude, intuitively qhia pipeline kev taw qhia sab laug / sab xis.

3. Conductor Cruise Mode: 360℃omnidirectional pipeline txoj kev qhia, tsis tu ncua tso saib qhov tob, tam sim no, thiab cov kav dej txheeb ze. Yooj yim, intuitive interface yuav tsum tsis muaj kev paub dhau los ua haujlwm.

4. Teeb liab Curve hom: Qhia keeb kwm teeb liab lub zog nkhaus. Nrhiav cov kab hluav taws xob los ntawm kev soj ntsuam cov teeb liab lub zog sib txawv ntawm ntau txoj haujlwm.

5. GPS Mapping Function: Saib geographic coordinates ntawm underground pipelines mapped los ntawm tus receiver ntawm lub mobile app daim ntawv qhia sab hauv. Ua tib zoo saib cov kev taw qhia hauv av hauv cov kab hluav taws xob los txiav txim siab txog kab faus kab.

6. Kev txiav txim siab tam sim no (xaiv zaus): Calibrates cov kev taw qhia tam sim no kom tshem tawm cov kab uas nyob ib sab thiab tiv thaiv kev taug qab tsis raug.

7. Ua tau-hauv Kev Tshawb Fawb Kev Tshawb Fawb: Cov neeg siv tuaj yeem xaiv lub teeb pom kev zoo zaus rau kev ntsuas cov kav dej raws li cov txiaj ntsig cheb, tsis txhob muaj kev cuam tshuam ntau zaus.

8. Tag Nrho Cov Digital Siab-Kev Ua Haujlwm Zoo Tshaj Plaws: Kev ua haujlwm ruaj khov thiab txhim khu kev qha nrog ultra-siab rhiab heev. Kev txais tos nqaim heev bandwidth muab kev tiv thaiv zoo - muaj peev xwm cuam tshuam, muaj txiaj ntsig zoo tiv thaiv lub zog zaus thiab kev cuam tshuam kev sib raug zoo los ntawm cov cables thiab cov kav dej uas nyob ib sab.

9. Ground Fault Locator (Yeem): Lub transmitter xa cov teeb liab tso rau hauv faulty cable. Siv lub A-thav duab (optional accessory), nrhiav qhov chaw txhaum hauv av ntawm lub raj xa dej nrog tus xub qhia txog kev taw qhia.

10. Ntau Yam Kev Tshawb Nrhiav Ntau Yam: 12 nquag nrhiav kom pom ntau zaus thiab 4 qhov kev kuaj pom tsis zoo.

11. Transmitter Signal Output Methods: Direct connection output, clamp coupling, thiab induction method.

12. Transmitter Digital Amplified Power Output nrog Siab Tsis Siv Neeg Impedance Matching thiab Kev Tiv Thaiv.

13. Ua- nyob rau hauv siab- teeb ci ntsa iab hauv qab lub ntsuas ntsuas rau kev ua haujlwm hmo ntuj.

 

Kev tsim tawm cov ntsiab lus

 

1. Municipal Planning and Construction: Utility line surveys, route detection, and depth measurement

2. Utility Maintenance Management: Pipeline/cable patrols, txhaum qhov chaw (grounding/insulation faults)

3. Fais fab kev lag luam: Cable ID (nyob / de-energized), cable txoj kev nrhiav, sheath fault detection

4. Kev Lag Luam Kev Sib Txuas Lus: Kev sib txuas lus cable txoj kev nrhiav pom, qhov chaw txhaum hauv av

5. Gas / Dej Kev Lag Luam: Hlau pipeline txoj kev kuaj pom, tiv thaiv -corrosion txheej kev puas tsuaj

6. Ua ntej-Kev Tshawb Nrhiav Kev Tsim Kho: Kev Tshawb Fawb Hauv Cheeb Tsam ua ntej kev khawb kom tsis txhob muaj kev puas tsuaj rau cov khoom siv hauv av

7. Engineering Surveying: GPS-pab cov kav xa dej hauv thaj chaw sib koom ua ke, cov ntaub ntawv qhia tsim

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

1) Dab tsi ntawm cov cables tuaj yeem txheeb xyuas qhov ua haujlwm ntawm ME -W9005 Pipeline Cable Comprehensive Detector txheeb xyuas?

Teb: Kev txheeb xyuas cov kab ke ua haujlwm ntawm cov cuab yeej no tuaj yeem txheeb xyuas ob qho tib si energized thiab de{0}}energized cables. Txawm li cas los xij, kev txheeb xyuas kab hluav taws xob muaj zog tsuas yog siv tau rau peb - tub ntxhais armored cables. Thaum lub sij hawm txheeb xyuas, xyuas kom lub transmitter clamp thiab receiver clamp tsis sib tov, thiab tswj cov teeb liab input kev taw qhia zoo ib yam. Thaum txheeb xyuas de- cov kab hluav taws xob muaj zog, tsis txhob txuas cov kab hluav taws xob nyob.

2) Lub teeb liab tso tawm txoj kev twg lub transmitter ntawm ME -W9005 Pipeline thiab Cable Locator txhawb nqa?

Teb: Lub transmitter muaj plaub lub teeb liab tso tawm txoj kev: Direct Connection Method, Clamp Coupling Method, Induction Method, thiab Neutral / Av / Sheath Txhaj Method. Txoj Kev Sib Txuas Direct muab lub teeb liab muaj zog tshaj plaws thiab raug pom zoo thaum twg los xij tso cai. Txoj kev Clamp Coupling yuav tsum tsis muaj kev sib cuag nrog cov kav dej ntawm cov khoom siv hlau, ua rau nws haum rau cov kav dej uas tsis yooj yim rau kov. Txoj Kev Induction yuav tsum tsis muaj kev xaim thiab tsim nyog rau kev kuaj xyuas cov kav dej tsis muaj cov ntsiab lus nthuav tawm. Txoj kev nruab nrab / hauv av / ntaub thaiv npog yog tsim rau cov xwm txheej tshwj xeeb xws li nyob qis -voltage cables.

3) ME -W9005 Pipeline & Cable Detector ua tiav nws txoj haujlwm li cas (yeem)?

Teb: Daim ntawv qhia kev ua haujlwm yuav tsum muaj kev sib txuas ntawm "Pipeline Detector + Smartphone + Android APP (tshaj nrog HarmonyOS)". Ua ntej, qhib lub mobile map app kom ua tiav kev sau npe thiab nkag mus. Tom qab ntawd qhib lub receiver lub Bluetooth thiab luam theej duab los khi lub cuab yeej ntawm lub app. Thaum kuaj pom, luv luv nias lub khawm sib txuas ntawm lub receiver kom xa cov ntaub ntawv ntsuas ntawm Bluetooth mus rau lub app. Lub app cia li sau cov chaw tswj hwm thaj chaw thiab npaj cov phiaj xwm kev qhia txog cov kav dej, thaum tseem tsim cov ntawv xeem uas muaj qhov tob, tam sim no, thiab lwm yam ntaub ntawv.

 

Cim npe nrov: Tuam Tshoj cable thiab yeeb nkab locator manufacturers, hoobkas

Xa kev nug