Transformer Fais Fab Analyzer

Xa kev nug
Transformer Fais Fab Analyzer
Paub meej
Lub MOEORW-WBW60 yog qhov siab -peb qhov tseeb peb-theem fais fab tus yam ntxwv ntsuas ntsuas tsim los rau kev ntsuas hluav taws xob, kev tsim hluav taws xob, thiab cov khoom siv hluav taws xob tu.
Nws nta tag nrho automated xeem ntawm tsis muaj -load/load poob, impedance, thiab harmonics.
cov teeb meem ntawm kev ntsuas tsis raug ntawm qhov tsis muaj zog, qhov loj waveform distortion yuam kev, thiab cumbersome phau ntawv hloov dua siab tshiab.
Nws yog qhov tsim nyog rau kev sim transformer Hoobkas, ntawm -kev tu vaj tse, thiab chaw kuaj ntsuas ntsuas ntsuas.
Kev faib tawm yam khoom
Transformer Test Set
Share to
Hauj lwm lawm

Khoom Taw Qhia

 

MOEORW-WBW60 Transformer Power Characteristic Analyzer yog ib qho cuab yeej tshwj xeeb tsim los ntawm peb lub tuam txhab rau kev ntsuas lub zog poob, impedance, thiab kev sib haum xeeb ntawm kev hloov pauv hluav taws xob, reactors, thiab motors. Cov cuab yeej no muaj peb qhov kev ywj pheej ntawm qhov hluav taws xob thiab peb txoj kev ywj pheej tam sim no, nrog ntau yam tsis siv neeg rau qhov ntsuas hluav taws xob thiab ntsuas tam sim no kom haum rau txhua txoj kev xaim thiab ntsuas. Nws cov yam ntxwv tseem ceeb yog nws lub peev xwm los ntsuas lub zog muaj zog txawm tias lub zog qis, ua rau nws tsim nyog rau kev ntsuas qhov poob ntawm lub zog loj transformers thiab reactors.

 

Khoom Parameter (Specification)

 

Cov khoom ntsuas

Kev ntsuas ntau

Qhov tseeb

Kev ntsuas ntau

Qhov tseeb

AC voltage

(Automatic range switching)

30V-750V

±0.1%

30V-1000V

±0.1%

Hloov tam sim no

(Automatic range switching)

0.05A-75A

±0.1%

0.05A-150A

±0.1%

Fais fab xwm txheej

0.2 Tsawg dua lossis sib npaug rau COSΦ Tsawg dua lossis sib npaug rau 1

±0.2%

0.2 Tsawg dua lossis sib npaug rau COSΦ Tsawg dua lossis sib npaug rau 1

±0.2%

0.015 Tsawg dua lossis sib npaug rau COSΦ Tsawg dua lossis sib npaug rau 0.2

±0.5%

0.015 Tsawg dua lossis sib npaug rau COSΦ Tsawg dua lossis sib npaug rau 0.2

±0.5%

Kev ntsuas zaus

45-65 Hz

±0.1%

45-65 Hz

±0.1%

40-200Hz

±0.2%

40-200Hz

±0.2%

 

Khoom nta thiab kev siv

 

1.Lub ntsuas ntsuas ntsuas tau ua raws li cov qauv ntsuas ntawm IEC76.1-93, GB1094.1-2003, thiab GB/T6451. Nws kuj tseem tuaj yeem tau txais qhov kho qhov hloov pauv tsis zoo nyob rau hauv qhov xwm txheej ntawm qhov hnyav waveform distortion ntawm qhov ntsuas hluav taws xob. Hauv particular, qhov tsis muaj-load poob tus nqi ntawm lub transformer yog kho thiab xam siv tus nqi nruab nrab ntawm lub voltmeter raws li cov qauv tsim.
2.Nws tuaj yeem ua tiav qhov kev ntsuam xyuas tsis siv neeg ntawm transformer tsis muaj-load poob, tsis muaj-load tam sim no, load poob, impedance voltage, luv-circuit impedance, thiab xoom-sequence impedance, thiab cia li hloov cov txiaj ntsig kev xeem mus rau peb-phase standard tej yam kev mob los tsim ib daim ntawv ntsuam xyuas tus qauv.
3.Standard AC parameter testing functions: Ntsuas qhov tseeb RMS tus nqi, tus nqi nruab nrab, lub zog ua haujlwm, lub zog reactive, lub zog muaj zog, zaus, thiab lwm yam hluav taws xob tsis zoo ntawm peb- theem voltage thiab tam sim no. Nws tseem tuaj yeem tso saib cov qauv ntawm txhua theem voltage / tam sim no thiab peb -phase voltage / tam sim no vector daim duab.
4.Harmonic tsom xam muaj nuj nqi: Ua harmonic tsom xam (31st order) ntawm peb -theem voltage thiab tam sim no, qhia cov ntsiab lus ntawm khib thiab txawm harmonics ntawm txhua theem thiab lub thawj theem kaum sab xis ntawm cov coj yoj, daim ntawv qhia bar ntawm txhua harmonic faib thiab tag nrho cov ntsiab lus harmonic.
5.Nws muaj qhov dav dav thiab ntsuas qhov ntsuas tam sim no, tsis siv neeg hloov pauv, thiab tuaj yeem txuas rau sab nraud CTs thiab PTs los ntsuas qhov poob thiab qhov cuam tshuam ntawm qhov loj - muaj peev xwm transformers thiab reactors.
6.Thaum ua qhov kev ntsuam xyuas poob ntawm cov hloov pauv loj, qhov ntsuas tsuas yog yuav tsum tau nkag mus rau DC qhov tseem ceeb ntawm txhua theem ntawm qhov cuam tshuam windings raug kuaj. Cov cuab yeej yuav txiav tawm qhov kev poob ntxiv cuam tshuam los ntawm DC qhov tseem ceeb raws li txoj kev xaim ntawm txoj hlua khi, thiab kho qhov hloov pauv hloov pauv mus rau qhov ntsuas tam sim no thiab tus qauv ntsuas kub.
Cov cuab yeej muaj RS-232 serial kev sib txuas lus interface, uas tuaj yeem txuas tau yooj yim rau lub khoos phis tawj los tsim lub tshuab hluav taws xob hloov hluav taws xob (poob) ntsuas qhov system. Tag nrho cov ntsuas AC ntsuas tau pom nyob rau ntawm lub computer screen.

 

Kev tsim tawm cov ntsiab lus

 

  • Lub tshuab hluav taws xob tau dhau los ua qhov kev sim ua tiav tag nrho ntawm qhov tsis muaj-load poob, load poob, luv-circuit impedance, thiab xoom-sequence impedance ua ntej tawm hauv lub Hoobkas / hom kuaj qhov chaw , thiab daim ntawv tshaj tawm cov qauv ntsuas tau muab.
  • Fais fab transformer ntawm -qhov chaw sim: ua ntej-commissioning thiab post-kev kuaj xyuas ntawm cov chaw nres tsheb kom sai sai tau qhov poob thiab impedance tsis.
  • Reactor/Motor Power Testing: Kev ntsuas qhov tseeb ntawm lub zog ua haujlwm nyob rau hauv cov xwm txheej tsis muaj zog; tau tshaj lub reactor thiab lub cev muaj zog poob thiab cov yam ntxwv kuaj.
  • Harmonic thiab fais fab kev soj ntsuam zoo: Peb-theem voltage thiab tam sim no harmonic tsom xam (31st order), nrog intuitive zaub ntawm waveforms thiab vector daim duab.
  • Loj - cov cuab yeej muaj peev xwm tuaj yeem txuas ntxiv mus kuaj CT / PT sab nraud kom tau raws li qhov siab - ntsuas qhov xav tau ntawm cov transformers loj thiab reactors.
  • Cov qauv ntsuas ntsuas ntsuas ntsuas ntsuas raws li IEC / lub teb chaws tus qauv thiab tuaj yeem siv los ua cov qauv ntsuas hluav taws xob ntsuas hluav taws xob thiab cov cuab yeej sib piv.

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

 

Q: Koj puas yog lub Hoobkas lossis tuam txhab lag luam?

A: Peb yog cov chaw tsim khoom ntawm cov khoom siv kuaj.

Q: Cov kev pab cuam tom qab muag zoo li cas?

A: Lub sijhawm lav yog 12 lub hlis. Tom qab lub sij hawm warranty, peb kuj muab kev pab them nqi kho mob los yog kev pab cuam lub neej.

Q: Cov kev pab cuam tom qab muag zoo li cas?

A: Lub sijhawm lav yog 12 lub hlis. Tom qab lub sij hawm warranty, peb kuj muab kev pab them nqi kho mob los yog kev pab cuam lub neej.

Q: Yuav ua li cas txog kev thauj mus los?

A: Nws nyob ntawm koj qhov kev xav tau. Peb tuaj yeem xa tuaj rau koj lub tshav dav hlau los ntawm huab cua, mus rau koj qhov chaw nres nkoj los ntawm hiav txwv, lossis rau koj lub chaw ua haujlwm los ntawm courier.
Peb kuj lees txais kev koom tes nrog koj tus neeg sawv cev shipping.

Q: Puas yog koj cov keyboard, interface, software, thiab phau ntawv txhais lus Askiv?

A: Yog, yog tias koj siv cov lus Askiv version ntawm cov keyboard, interface, software, thiab phau ntawv thiab xav tau lwm hom lus, thov hu rau peb kom paub meej.

 

Cim npe nrov: Tuam Tshoj transformer fais fab analyzer manufacturers, hoobkas

Xa kev nug