Khoom Taw Qhia
Hauv kev tsim cov khoom siv hluav taws xob, DC tsis kam lossis kev ntsuas qhov sib piv yuav tsum tau ua thaum lub sijhawm ib nrab -cov khoom tiav thiab tiav cov khoom lag luam kuaj, kev teeb tsa, kho dua tshiab, hloov pauv hloov pauv, kev sim ua haujlwm, thiab kev ntsuas kev tiv thaiv los ntawm lub zog hluav taws xob. Cov kev ntsuas no tseem tuaj yeem kuaj xyuas cov vuam zoo ntawm cov pob qij txha winding thiab rau inter-tig luv luv Circuit Court, txheeb xyuas qhov kev sib cuag zoo ntawm txhua txoj haujlwm ntawm qhov hloov hluav taws xob hloov hluav taws xob, lees paub qhov kev sib txuas lus ntawm qhov tseeb thiab qhia kais hloov pauv txoj haujlwm, tshawb xyuas cov hlau lead tawg, thiab tshuaj xyuas ntau - cov xov hlau rau cov hlua tawg. Kev sim tshuaj ib txwm xav tau ntau lub sijhawm sib txuas siv ob lub cuab yeej, uas yog lub sijhawm-siv, tsis muaj txiaj ntsig, thiab cuam tshuam loj rau cov sijhawm tsim khoom.
Yuav kom ua tau raws li qhov xav tau ntawm kev ntsuas ceev ntawm transformer DC tsis kam thiab hloov pauv, peb lub tuam txhab tau tsim MOEORW- W 4670Q Transformer DC Resistance thiab Turns Ratio Comprehensive Tester . Cov cuab yeej no siv ib qho - lub sij hawm xaim kev sib txuas thiab tuaj yeem ua tiav qhov kev ntsuas qhov sib piv thiab DC tsis kam kuaj ntawm tag nrho rau theem (siab thiab qis) yam tsis muaj kev cuam tshuam cov xaim. Cov haujlwm no tuaj yeem ua tiav los ntawm kev ua haujlwm touchscreen.
Khoom Parameter (Specification)
Cov ntsiab lus tseem ceeb ntawm DC Resistance:
| Tam sim no | AUTO,<20 mA, 40 mA, 200 mA, 1A, 3A, 10A |
| DC tsis kam kuaj ntau yam & raug |
10A: 0.5 mΩ-800 mΩ ± (0.2% +2 tus lej) 3A: 5 mΩ-2 Ω ± (0.2% +2 tus lej) 1A: 10 mΩ-10 Ω ± (0.2% +2 tus lej) 200mA: 100 mΩ-50 Ω ± (0.2% +2 tus lej) 40mA: 500 mΩ-250 Ω ± (0.2% +2 tus lej) <20mA: 50 Ω~50 KΩ ±(0.5%+2 digits) |
| Yam tsawg kawg nkaus daws teeb meem | 0.1 μΩ |
| Zaub | LCD saib, tsis kam tso saib nrog 4 tus lej tseem ceeb |
| Cov ntaub ntawv khaws cia | 1000 sets |
| Kev ua haujlwm ib puag ncig |
Ambient kub: -20 ℃ -40 ℃ txheeb ze humidity:<80%RH, non-condensing |
| Fais fab mov | AC 220V ± 10V, 50Hz ± 1Hz, Fuse 5A |
| Kev siv hluav taws xob siab tshaj plaws | 200W |
| Qhov hnyav |
Qhov hnyav: 8.5 kg Accessory box: 9.5 kg |
Cov cim tseem ceeb ntawm transformer ratio:
| Kev xeem ntau yam |
Transformer piv: 0.9 ~ 10000 Lub kaum sab xis: 0 ~ 360 degree |
| Ratio qhov tseeb |
± 0.1% + 2 tus lej (0.9 ~ 500) ± 0.2% + 2 tus lej (501 ~ 2000) ± 0.5% + 2 tus lej (2001 ~ 10000) |
| Lub kaum ntse ntse | ± 0.2 degree |
| Output voltage | Tsis siv neeg kho raws li lub load |
| Kev daws teeb meem |
Ratio: min . 0.0001 Lub kaum sab xis: 0.01 degree |
| Kev ua haujlwm fais fab | AC220V ± 10%, 50 ± 1Hz |
| Ambient kub | -10℃-40 degree |
| txheeb ze humidity | Tsawg dua los yog sib npaug li 85%, tsis muaj condensation |
Khoom nta thiab kev siv
Cov yam ntxwv ntawm DC tsis kam ua haujlwm
- Cov khoom no yog tsim rau kev kuaj inductive loads xws li 10 kV thiab 35 kV tis transformers, ntsuas transformers, motors, thiab generators, raws li zoo raws li ntsuas nyob ntawm tej, relay hloov hu, thiab lwm yam.
- Nws muaj qhov hloov pauv kub ua haujlwm, uas tuaj yeem hloov pauv tus nqi tsis kam mus rau qhov sib txawv raws li cov neeg siv khoom xav tau, ua rau nws yooj yim los sib piv cov ntaub ntawv.
- Nws muaj kev tiv thaiv kev ua haujlwm xws li tso tawm suab tswb, lub hwj chim overheating, thiab rov qab voltage txuas.
- Lub rau ntawm -load hloov pauv tuaj yeem hloov ncaj qha rau hauv lub xeev ntsuas, thiab lub ntsuas yuav cia li hloov kho cov ntaub ntawv yam tsis tas yuav rov pib ua haujlwm.
- Nws muaj 6 qib tam sim no thiab tsis siv neeg tam sim no qib xaiv muaj nuj nqi, uas tuaj yeem xaiv cov qib tam sim no raws li cov khoom thauj.
Transformer Ratio Functional Yam ntxwv
- Cov cuab yeej siv peb lub -theem precision inverter fais fab mov, uas tshem tawm cov teebmeem kev sib haum xeeb ntawm lub zog hluav taws xob thaum ntsuas, ua rau kev ntsuas ntau dua. Tsis muaj kev cuam tshuam thaum lub zog ua haujlwm yog lub tshuab hluav taws xob.
- Nws txais peb -theem tso zis voltage los txhim kho qhov ntsuas ceev. Nws tuaj yeem ntsuas lub kaum sab xis ntawm lub kaum sab xis thiab tuaj yeem txheeb xyuas cov kab hluav taws xob 0-11. Rau rectifier transformers nrog ntau windings nyob rau hauv qis voltage, qhov lem piv thiab 7.5℃lub kaum sab xis deviation yuav ntsuas tsis tau disconnecting qhov tsawg voltage sab.
- Nws muaj feem xyuam rau ntau hom transformer, tshwj xeeb tshaj yog haum rau ntsuas Z-hom transformers, rectifier transformers, grounding transformers, hluav taws xob rauv transformers, thiab lwm yam.
- Nws nta siab thiab qis voltage rov qab kev twb kev txuas tiv thaiv, transformer inter-tig luv Circuit Court tiv thaiv, kais changer tsis tiav qhib / kaw tiv thaiv, thiab tso zis tag nrho luv luv Circuit Court tiv thaiv, ua kom ntsuas stability.
- Tom qab nkag mus rau qhov ntsuas ntsuas, nws tuaj yeem ntsuas qhov hloov pauv hloov pauv, tus nqi yuam kev, thiab kais txoj haujlwm. Tshwj xeeb tshaj yog rau cov kais dej nrog cov kais dej asymmetrical, nws tuaj yeem ntsuas qhov tseeb ntawm txoj haujlwm ntawm cov kais dej hloov pauv. Nws tuaj yeem ntsuas txog 99 kais txoj haujlwm.
- Xya -inch siab- brightness touchscreen xim LCD, pom meej txawm nyob hauv lub teeb muaj zog, ua haujlwm puv npo, thiab hloov pauv dawb ntawm Suav thiab Askiv.
Kev tsim tawm cov ntsiab lus
Factory thiab ntau lawm xeem
Transformer semi{0}}cov khoom tiav thiab cov khoom tiav hauv lub Hoobkas kuaj
01
Ntawm - qhov chaw teeb tsa thiab kev saib xyuas
Transformer installation, overhaul, handover testing, thiab post- coj mus rhaub hloov tshuaj ntsuam
02
Hluav taws xob tiv thaiv kev sim
Kev ua haujlwm ntawm daim phiaj hluav taws xob thiab kev saib xyuas, kev tiv thaiv ib ntus thiab kev ntsuas kev ua haujlwm
03
Winding thiab Connector Diagnosis
Kev tshuaj xyuas qhov zoo ntawm winding welding zoo, inter-tig short circuit troubleshooting, lead wires, and break strands in parallel-mob conductors.
04
Kev kuaj khoom siv dav dav
DC kuj ntsuas ntawm inductive loads xws li 10kV / 35kV faib transformers, ntsuas transformers, motors, thiab generators.
05
Lub Tuam Txhab Txuj Ci
FAQ
Q: Koj puas yog lub Hoobkas lossis tuam txhab lag luam?
A: Peb yog cov chaw tsim khoom ntawm cov khoom siv kuaj.
Q: Cov kev pab cuam tom qab muag zoo li cas?
A: Lub sijhawm lav yog 12 lub hlis. Tom qab lub sij hawm warranty, peb kuj muab kev pab them nqi kho mob los yog kev pab cuam lub neej.
Q: Cov kev pab cuam tom qab muag zoo li cas?
A: Lub sijhawm lav yog 12 lub hlis. Tom qab lub sij hawm warranty, peb kuj muab kev pab them nqi kho mob los yog kev pab cuam lub neej.
Q: Yuav ua li cas txog kev thauj mus los?
A: Nws nyob ntawm koj qhov kev xav tau. Peb tuaj yeem xa tuaj rau koj lub tshav dav hlau los ntawm huab cua, mus rau koj qhov chaw nres nkoj los ntawm hiav txwv, lossis rau koj lub chaw ua haujlwm los ntawm courier.
Peb kuj lees txais kev koom tes nrog koj tus neeg sawv cev shipping.
Q: Puas yog koj cov keyboard, interface, software, thiab phau ntawv txhais lus Askiv?
A: Yog, yog tias koj siv cov lus Askiv version ntawm cov keyboard, interface, software, thiab phau ntawv thiab xav tau lwm hom lus, thov hu rau peb kom paub meej.
Cim npe nrov: Tuam Tshoj transformer puv ratio & winding kuj tester, Tuam Tshoj transformer puv ratio & winding kuj tester manufacturers, hoobkas