Ob -terminal Ground Loop Resistance Tester

Xa kev nug
Ob -terminal Ground Loop Resistance Tester
Paub meej
MOEORW-W5020TB Ob-terminal Ground Loop Resistance Tester nta wireless clamp meters nrog Bluetooth / RS232 kev sib txuas lus, ua kom muaj chaw taws teeb ua haujlwm thiab xa cov ntaub ntawv. Nws cov ntse triple-mode + tsoos- hom kev pab them nqi, siab- ntsuas qhov tseeb, thiab loj- muaj peev xwm khaws cia redefine lub zog voj tiv thaiv kev sim.
Kev faib tawm yam khoom
Hu rau Resistance Tester
Share to
Hauj lwm lawm

Ob -terminal Ground Loop Resistance Tester

 

Khoom Taw Qhia

 

Ob -terminal ground loop resistance tester yog tsim tshwj xeeb rau kev tshawb nrhiav lub hwj chim system grounding loops thiab substation grounding chaw. Nws tau txais kev tshaj lij ob- lub ntsiab lus ntsuas qhov kawg, daws cov teeb meem ntawm kev sim hauv av ib txwm muaj xws li kev cuam tshuam loj thiab cov xwm txheej tsawg. Cov cuab yeej muaj zog ntawm -qhov chaw tiv thaiv- cuam tshuam kev ua tau zoo, paub tsis yog -disassembly tshawb pom cov voj voog hauv av, thiab muab cov ntaub ntawv raug thiab txhim khu kev qha rau kev nyab xeeb ntawm lub zog hauv av.

 

Khoom Parameter (Specification)

 

2.1 Main Unit Technical Specifications

Xeem tam sim no

50A/100A/150A/200A

Ntau yam

0μΩ txog 80mΩ (50A);

0μΩ txog 40mΩ (100A);

0μΩ txog 20mΩ (150A);

0μΩ txog 10mΩ (200A).

Yam tsawg kawg nkaus daws teeb meem

0.01μΩ.

Kev ntsuas hom

 

Ib txwm ua haujlwm hom

50A/100A/150A/200A;

Intelligent Test Mode

"Clamp Meter Direct Measurement Mode," "Ib zaug-Side Shunt Mode," "Dual-Side Shunt Mode."

Lub sijhawm ntsuas

Kev ntsuas kev ntsuas kev ua haujlwm ib txwm muaj

Ceev / 10s / 30s / 60s / Nruam;

Intelligent test mode

Ceev / 10s / 30s / 60s.

Kev ntsuas qhov tseeb

Kev ntsuas kev ua haujlwm ib txwm muaj; ± (Nyeem × 0.5% + 0.2μΩ);

Intelligent test mode

± (Nyeem × 2% + 0.5μΩ).

Kev khiav hauj lwm voltage

AC220V ± 10%.

Ua haujlwm kub

-10℃txog 50 degree.

txheeb ze humidity

Tsawg dua lossis sib npaug li 90% RH, tsis yog -condensing.

Qhov ntev

36 x 29 x 16 cm.

Qhov hnyav

6, 2kg.

2.2 Clamp Meter Technical Specifications

Kev ntsuas ntsuas

Hall- cuam tshuam clamp, tsis yog - ntsuas ntsuas.

Kev ntsuas ntau

DC 0 rau 600A.

Kev ntsuas qhov tseeb

± (2% ntawm kev nyeem ntawv + 0.5A).

Kev daws teeb meem

DC 0.01μΩ

Hom zaub

LCD.

Fais fab mov

Ua - hauv lithium roj teeb.

Lub puab tsaig loj

Φ68 hli.

 

Khoom feature thiab daim ntawv thov

 

• Nta lub siab -brightness 7-inch xim LCD npo nrog cov zaub ntshiab, cov neeg siv tau zoo interface, thiab hnub ci nyeem tau.

• Tag nrho chav tswj los ntawm siab - chips ceev, muab siab automation thiab ua haujlwm yooj yim.

• Cov zis siab tshaj plaws tam sim no ncav cuag 200A, xa cov kev ntsuas ceev ceev thiab ntsuas qhov tseeb.

• Sib koom ua ke ob qho tib si "Tsev Kev Ntsuas Kev Ntsuas" thiab "Kev Ntsuas Ntsuas Ntsuas" kom ua tau raws li cov ntawv thov sib txawv.

• "Kev Ntsuas Kev Txawj Ntse" ua rau kev ntsuas meej ntawm kev hloov hluav taws xob tiv thaiv yam tsis muaj kev cuam tshuam hauv av, txuag lub sijhawm thiab kev siv zog thaum txo qis kev ua haujlwm. Nws tseem tshem tawm kev nyab xeeb kev nyab xeeb rau cov neeg ua haujlwm thiab cov khoom siv los ntawm "cov av cuav."

• Kev tiv thaiv zoo xws li overcurrent, luv-circuit, thiab overheat tiv thaiv.

• Ua tau-hauv loj- muaj peev xwm tsis- lub cim xeeb tsis hloov pauv mus txog 512 cov ntaub ntawv teev, txhawb kev tshuaj xyuas thiab xa tawm.

• Kev sib xyaw ua ke siab - moos precision qhia lub sijhawm tiag - lub sijhawm.

• USB cia ua haujlwm.

• Nruab nrog lub tshuab luam ntawv thermal ua ke, tso cai rau cov neeg siv luam tawm cov txiaj ntsig ntsuas ntawm lub pob tshwj xeeb. Cov ntaub ntawv xeem keeb kwm kuj tuaj yeem luam tawm.

• Integrated RS232 interface thiab Bluetooth kom yooj yim cov ntaub ntawv upload thiab tswj chaw taws teeb.

 

Kev tsim tawm cov ntsiab lus

 

Tsim los rau siab -kev ntsuas qhov siab ntawm siab-voltage switch contact resistance (loop resistance), txhawb nqa ib leeg / dual- qhov kawg grounding tests yam tsis tau disassembled lub voj grounding. Qhov zoo tshaj plaws rau ntawm - qhov chaw siab -voltage hloov kho los ntawm lub hwj chim thiab chaw siv hluav taws xob, nrog rau kev ntsuas ntsuas ntsuas ntawm siab -voltage switch manufacturers.

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

1) Dab tsi yog qhov zoo ntawm hom kev ntsuas ntse ntawm MOEORW-W5020TB Dual-End Ground Loop Resistance Tester?

Teb: Cov cuab yeej ntsuas kev txawj ntse hom suav nrog peb qhov chaw: clamp meter ncaj ntsuas, ib zaug -sab shunt, thiab dual- sab shunt. Nws qhov txiaj ntsig tseem ceeb nyob hauv kev ua kom muaj kev ntsuas meej ntawm kev hloov hluav taws xob tiv thaiv yam tsis muaj kev cuam tshuam lub hauv paus busbar, txuag lub sijhawm thiab kev siv zog thaum txo qis ntawm - chaw ua haujlwm. Nws tseem tshem tawm kev nyab xeeb kev nyab xeeb rau cov neeg ua haujlwm thiab cov khoom siv los ntawm "tsis muaj tseeb hauv av," ua kom muaj kev nyab xeeb thiab ua tau zoo ntawm cov txheej txheem ntsuas kom haum rau ntau yam xwm txheej hauv av.

2) Puas yog lub wireless clamp meter ntawm MOEORW-W5020TB Dual-End Ground Loop Resistance Tester tsuas ntsuas DC tam sim no? Dab tsi yuav tsum tau ceev faj thaum siv los tiv thaiv kev puas tsuaj?

Teb: Yog, lub wireless clamp meter ntawm qhov ntsuas no tsuas tuaj yeem kuaj DC tam sim no. Ob lub ntsiab lus xav tau kev saib xyuas thaum siv: Ua ntej, qhov ntsuas qhov ntsuas yog DC 0600A. Tsis txhob tshaj qhov ntsuas ntau, vim qhov no yuav ua rau lub ntsuas ntsuas clamp puas. Qhov thib ob, lub clamp meter muaj qhov zoo tam sim no kev taw qhia (tam sim no ntws mus rau pem hauv ntej lub ntsej muag). Thaum calibrating lub clamp 'meter', xyuas kom meej qhov ntsuas qhov tso zis tam sim no ntws los ntawm clamp meter nyob rau hauv txoj kev zoo.

3) Dab tsi yog qhov yuav tsum tau ua ntawm qhov ntsuas hluav taws xob ntsuas hluav taws xob thiab cov hlau lead tam sim no thaum ua haujlwm txuas rau MOEORW-5020TB Dual-End Ground Loop Resistance Tester?

Teb: Thaum txuas cov xov hlau, xyuas kom meej qhov ntsuas qhov ntsuas hluav taws xob nyob hauv cov hlau lead tam sim no. Ua ntej txuas los yog txiav cov kev xeem coj, lub ntsuas yuav tsum raug kaw. Tsuas yog siv cov kev kuaj mob tshwj xeeb uas tau muab. Khaws cov coj mus txuas ntxiv thaum siv; tsis txhob co lawv kom tsis txhob cuam tshuam cov txiaj ntsig kev xeem lossis ua rau muaj kev nyab xeeb.

 

Cim npe nrov: ob-terminal av voj tsis kam tester, Tuam Tshoj ob-terminal av voj tsis kam tester manufacturers, hoobkas

Xa kev nug