Cov khoom luv luv
MOEORW-WAS88H yog dual-function handheld acoustic imager integrating MEMS mic array thiab uncooled VOx infrared thermal camera. Nws txais yuav cov suab nrov dhau los ua kom lub suab tsis sib xws nrog cov xim gradient huab maps, txhawb nqa tag nrho -spectrum capture ntawm lub suab mus rau siab - zaus ultrasound. Chav tsev sib txuas ua ke acoustic positioning thiab tiag -lub sij hawm thermal ntsuas ntsuas los kuaj xyuas ib feem ntawm qhov tsis xws luag nyob rau hauv siab -voltage fais fab cuab tam thiab me me compressed gas leaks. Nws koom ua ke laser rangefinder, ntxiv lub teeb puv, ntau-qib digital zoom, thiab ntawm{11}}board data analytics, ua kom tag nrho - hauv- ib qho kev soj ntsuam tsis muaj cov cuab yeej pab ntxiv. Ob qho tib si ib ntus thiab khov kho lub suab ntawm qhov chaw nres tsheb lossis lub tshuab txav tuaj yeem raug ntes nrog cov duab tso tawm ruaj khov.
Technical Parameter Table
Acoustic Measurement Module
|
Parameter |
Specification |
|
Microphone Array |
144-channel MEMS cov microphones |
|
Kev khiav hauj lwm zaus Band |
2 kHz ~ 130 kHz |
|
Qhov Ntsuas Ntsuas Qhov Ncauj Zoo |
0.3m ~ 150m |
|
Tiag -time Imaging Frame Rate |
30 FPS ua |
|
Angular Scanning Qhov tseeb |
Tsawg dua lossis sib npaug li 1 degree |
|
Spatial Positioning yuam kev |
Tsawg dua lossis sib npaug li 1cm (1m nrug, 40kHz xeem zaus) |
|
Suab Siab rhiab heev |
10kHz: 3dB SPL; 20kHz / 40kHz: -5dB SPL; 60kHz: 10dB SPL; 80kHz: 35dB SPL; 100kHz: 45dB SPL |
|
Yam tsawg kawg Detectable Leak Flow |
Tsawg dua lossis sib npaug li 0.05 L / min @ 10m, 1.2bar ua haujlwm siab |
Infrared Thermal Imaging Module
|
Parameter |
Specification |
|
Ntes Hom |
Uncooled Vanadium Oxide (VOx) focal dav hlau array |
|
Detector daws teeb meem |
640 × 512 pixels |
|
Ib qho Pixel Loj |
12μm |
|
Infrared Teb Band |
8μm ~ 14μm ntev -wave infrared |
|
NETD Thermal Sensitivity |
Tsawg dua lossis sib npaug li 40mK (25℃ambient, F#=1.0) |
|
Dual -Range Temperature Scale |
-20℃~ 150℃/ 100℃~ 550 degree |
|
Temperature Reading Deviation |
± 2℃lossis ± 2% ntawm tus nqi ntsuas (tus nqi loj dua) |
|
Spatial daws teeb meem |
0,8m ua |
|
Tsau Lens Focal Length |
15 hli |
|
Field of View |
Kab rov tav: 29.3 degree, Vertical: 23.4 degree, kab pheeb ces kaum: 37.5 degree |
|
Thermal Image Refresh Rate |
30 Hz |
Pom Lub Teeb & Cia Khoom Siv
|
Parameter |
Specification |
|
Visible Camera FOV |
72℃± 3 degree |
|
Pom tau Lens |
Tsau 3.9mm focal ntev |
|
Pom Duab Pixel suav |
13 MP |
|
Tseem Duab tso zis daws teeb meem |
3840×2160 / 1920×1080 |
|
Video Recording Spec |
1080P, 30FPS ncej tus nqi |
|
Standard Storage Medium |
128GB Micro SD daim npav, muaj peev xwm nthuav tau |
Mechanical & Electrical Properties
|
Parameter |
Specification |
|
Zaub Screen |
5-nti capacitive LCD, 1280 × 720 daws teeb meem |
|
Digital Magnification |
1 × / 2 × / 4 × / 8 × adjustable |
|
Zuag qhia tag nrho cov Dimensions |
333mm × 152mm × 115mm |
|
Net Device Nyhav |
Tsawg tshaj li 1.2 kg |
|
Ua - hauv Lithium roj teeb |
Ntau tshaj lossis sib npaug rau 4500mAh, ntsuas 7.2V |
|
Charging Standard |
Hom -C PD them ceev ceev, dual charging hom (device direct charge + dedicated charging dock) |
|
Laser Distance Ntsuas Scope |
0.1m ~ 20m |
|
Kev sib txuas lus wireless |
Dual-band Wi-Fi (2.4G+5G), Bluetooth 4.2 |
|
Kev khiav hauj lwm ambient kub |
-20℃~ +55 degree |
|
Cia qhov kub thiab txias |
-40℃~ +85 degree |
|
Humidity Ua Haujlwm Li Cas |
10% ~ 95% RH, tsis yog -condensing ib puag ncig nkaus xwb |
|
Ingress Protection Rating |
Tsawg kawg IP54 |
|
Sab nraud Tripod Interface |
UNC 1/4-20 tus qauv xov |
|
Kev them nyiaj yug System Language |
Ntau hom lus thoob ntiaj teb pob khoom (CN/EN/RU/ES/DE/FR/TH/IT/TR) |
Core Product Advantages
1. Tag nrho -hauv-ib qho Kev Sib Txuas Khoom Siv Hluav Taws Xob Ua ke ua ke acoustic sensor matrix, infrared thermal detector thiab pom lub lens rau hauv ib lub tes tuav, tshem tawm qhov xav tau rau cov koob yees duab sab nraud.Compact lub cev hnyav txhawb nqa ib leeg - tes ntev {{5} lub sijhawm ua haujlwm rau lub cev, nrog rau kev ua haujlwm ywj pheej rau kev ua haujlwm, nrog rau kev ua haujlwm ntawm lub cev muaj zog triggering, nrog rau kev ua haujlwm ntawm lub cev muaj zog ua kom yooj yim ntawm - qhov chaw ua haujlwm ua haujlwm.
2. Ultra-wide Frequency High-stability Acoustic Detection 144 ywj siab MEMS microphones paub dab- dawb tiag- lub sij hawm suab teb duab hla 2kHz–130kHz tag nrho spectrum, npog ob qho tib si audible mechanical suab nrov thiab siab -frequency meter{0} txoj hauj lwm ultrasonic kom raug pinpoints me me qhov chaw suab, nrog rau kev xaiv lub hauv paus tsom xam hom los lim tawm ambient cuam tshuam rau cov teeb liab tsis muaj zog.
3. Dual-modal Suab & Thermal Synchronized Diagnosis Tshwj xeeb infrared ntsuas kub ntsuas module tso cai rau ntau- qhov ntsuas kub ntsuas: ib qho taw tes, linear profile, cheeb tsam cheeb tsam thiab qhov sib txawv ntawm qhov sib piv.15 customizable infrared pseudo- xim hom ntxiv rau ntau lub suab teb cov xim thermal overheating thiab kev sib piv ntawm cov xim sib txawv ib txhij.
4. Peb Cov Txheej Txheem Kev Ntsuas Kev Ntsuas Kev Ntsuas Peb Peb txoj haujlwm hloov pauv tau tsim rau cov xwm txheej sib txawv ntawm kev lag luam: Hom Kev Tso Tawm Ib Nrab tsim tawm tiag tiag- lub sijhawm PRPD theem- daws teeb meem thiab nws pib- faib cov paug tawm tsis xws luag; Gas Leak Mode xam cov nyiaj poob qis tiag {4} txhua xyoo; Hom outputs kurtosis, crest factor thiab spectrum variation metrics rau rotating khoom txhaum ceeb toom ntxov.
5. Tag nrho- txheej txheem Cov Ntaub Ntawv Hauv Zos Kev Muaj Peev Xwm Txhawb Nqa cov duab tam sim thiab yees duab, ntau - cov ntaub ntawv annotation (cov ntawv, suab, duab, cim cim), ntawm - pawg thawj coj saib thiab lub sijhawm- zaus spectrum tsom xam, thiab ib qho -nias PDF soj ntsuam daim ntawv tshaj tawm, Wi-nkaus {7} tuaj yeem kis tau los ntawm kev sib txuas lus, Wi-nkaus lossis upload rau huab cia servers rau kev tshuaj xyuas tej thaj chaw deb.
6. nplua nuj Expandable System Functional Modules Nruab nrog tej thaj chaw deb OTA firmware txawj tej yam ntxiv thiab lub zos offline hloov tshiab zog, Bluetooth lub mloog pob ntseg saib xyuas, hluav taws xob compass zaub, nws pib screen brightness hloov, thiab adjustable suab teb imaging ntau kom haum rau complex industrial teb cheeb tsam.
Target Application Scenarios
1.Power Grid Inspection:Kev daws teeb meem ib nrab rau cov transformers, siab -voltage switchgears, busbars, cable terminals thiab ntes; tsis siv neeg txheeb xyuas tus kab mob corona, nto thiab ntab rwb thaiv tsev tso tawm txhaum.
2. Pneumatic System Maintenance:Compressed cua pipeline, valve, flange thiab siab lub nkoj xau kom pom; Kev suav lej ntawm cov roj poob thiab kev lag luam txhua xyoo kev lag luam pov tseg.
3.Heavy Industry Rotating Equipment Monitoring:Kev kuaj lub suab nrov tsis zoo rau cov motors, bearings, gearboxes thiab dej twj; Kev kwv yees thaum ntxov ntawm cov khoom hnav thiab cuam tshuam tsis ua haujlwm los ntawm cov cim ntsuas acoustic.
4.Factory Thermal Fault Inspection:Overheating nrhiav tau ntawm hluav taws xob tiv tauj, thaiv cov terminals thiab cov khoom siv plhaub; synchronous acoustic anomaly soj ntsuam ua ke nrog ntsuas kub sib txawv rau cov khoom siv hluav taws xob sib pauv.
5.Public Infrastructure Inspection:Npog cov raj xa dej kom pom, qhov cua tshuab ua pa txawv txav tsis zoo ntawm lub suab nrov, kev sib xyaw ua ke thermal thiab acoustic tshuaj xyuas rau cov khoom hluav taws xob hauv cov tsev.
FAQ
Q: Suab teb hotspots drift tsis tu ncua thaum ntsuas
A: Re-calibrate lub zaus band kom phim lub ultrasonic zaus ntawm lub hom phiaj to los yog tawm; hloov mus rau nws pib zaus hom los yog ua kom cov duab txhim kho rau cov suab tsis muaj zog.
Q: Ob lub suab cim tshwm thaum tsuas muaj ib lub suab lub cev muaj nyob
A: Cov cim thib ob pib los ntawm lub suab nthwv dej xav txog. Kho cov cuab yeej tua lub kaum ntse ntse ntau zaus; cov cim los ntawm lub suab ncaj nraim nyob ruaj thaum cov cim qhia tau hloov nrog lub kaum sab xis hloov.
Q: Infrared thermal imaging module tsis tso tawm
A: Paub meej tias tus qauv ntaus ntawv yog MOEORW-WAS88H nrog cov khoom siv hluav taws xob sib xyaw ua ke; xyuas cov roj teeb theem thiab tag nrho recharge lub tsev yog tias tsis tshua muaj hluav taws xob tshwm sim.
Q: Tsis muaj suab thaj huab tau tshwm sim tom qab tsom ntawm qhov pom tseeb ntawm txoj haujlwm xau
A: Txo tus nqi acoustic imaging qhov pib kom phim lub suab zog siv ntawm lub hom phiaj ntsuas.
Q: Lub kaw lus tsis lees paub firmware hloov kho cov ntaub ntawv khaws cia hauv USB flash drive
A: Format USB cia rau FAT32 cov ntaub ntawv kaw lus; khaws unmodified upgrade tej pob khoom nyob rau hauv lub hauv paus directory thiab paub meej tias lub firmware version yog tshiab dua li cov cuab yeej tsim tam sim no.
Cim npe nrov: tag nrho-hauv-ib infrared-acoustic imager, Tuam Tshoj tag nrho-hauv-ib infrared-acoustic imager manufacturers, hoobkas