Cable HFCT Ib Feem Tso Tawm Online Saib

Xa kev nug
Cable HFCT Ib Feem Tso Tawm Online Saib
Paub meej
MOEORW-W5087C yog ib qho online PD saib rau siab -voltage cables thiab pob qij txha.
Txais 3-channel HFCT Rogowski coil sensors, nws ntes tsis muaj zog tawm pulses nrog rhiab heev <5pC.
Qhib -clamp sensors pab tsis tau -invasive installation. Compact, lub teeb yuag thiab dual- fais fab mov, nws yog zoo meej rau ntev- cable rwb thaiv tsev xyuas.
Kev faib tawm yam khoom
Cov cuab yeej soj ntsuam online
Share to
Hauj lwm lawm

Khoom Taw Qhia

 

MOEORW-W5087C yog lub chaw tshwj xeeb saib xyuas rau siab -voltage cables thiab cable txuas. Nws txais siab - zaus tam sim no transformer (HFCT) raws li Rogowski coil hauv paus ntsiab lus los ntes cov pa tawm tsis muaj zog ntawm cov xaim hauv av. Nrog cov qauv compact thiab siab rhiab heev, nws yog qhov zoo tagnrho rau ntev -lub sij hawm ntawm - kab saib xyuas ntawm cable rwb thaiv tsev.

 

Khoom Parameter (Specification)

 

Cov channel 3-channel parallel ntsuas
Kev kuaj pom rhiab heev ± 1 dB (rau txhua qhov channel)
Tshawb nrhiav Dynamic Range 60dB ib
Kev Tshawb Nrhiav Teeb liab Bandwidth Siab -Frequency Current (HFCT): 3 MHz – 30 MHz
Fais fab mov 220V AC los yog 24V DC (xaiv tau)
Synchronization Txhawb fais fab zaus synchronization
Kev sib txuas lus Interface RJ45, RS485

 

Khoom nta thiab kev siv

 

  • 3-channel HFCT teeb liab tau txais nplooj siab rau kev kuaj xyuas kab mob
  • Qhib-kaw sensor qauv, kev teeb tsa ceev yam tsis muaj kev cuam tshuam hauv av
  • rhiab heev<5pC, 60dB dynamic range, reliable for minor discharge detection
  • Yeem 220V / 24V fais fab mov, ntuj txias, hnyav<500g
  • Haum rau siab -voltage cables, cable terminals, GIS grounding circuits

 

Khoom siv

 

  • High-voltage fais fab cables thiab cable davhlau ya nyob twg txuas
  • Cable trench, box-hom substations thiab tis chaw nres tsheb
  • GIS grounding circuit PD nrhiav kom tau
  • Cable kab ntse saib xyuas thiab kho mob

 

Lub Tuam Txhab Txuj Ci

 

 

FAQ

 

Q: Dab tsi yog qhov tseem ceeb ntawm kev tshawb nrhiav?

A: Nws siv HFCT (siab- zaus tam sim no transformer) rau cable grounding pulse detection.

Q: Puas yog sensor installation intrusive?

A: Tsis yog. Qhib-kaw qauv ua kom muaj kev teeb tsa sai yam tsis muaj kev cuam tshuam hauv av.

Q: Dab tsi yog qhov kev tshawb nrhiav rhiab heev?

A: rhiab heev yog <5pC, dynamic ntau 60dB.

Q: Cov kev xaiv fais fab twg tau txais kev txhawb nqa?

A: 220V AC lossis 24V DC yog xaiv tau.

Q: Tus ntaus ntawv hnyav yog dab tsi?

A: Tsawg dua 500g (tsis muaj sensors), haum rau qhov chaw me me.

 

Cim npe nrov: cable hfct ib nrab tawm hauv online saib, Tuam Tshoj cable hfct ib nrab tawm hauv online saib manufacturers, hoobkas

Xa kev nug