Khoom Taw Qhia
MOEORW-WEH107 Dej-Soluble Acid Tester rau Transformer Roj, tseem hu ua Transformer Roj Dej-Soluble Acid Detector, Tsis Siv Neeg Dej-Soluble Acid Analyzer thiab 6-Cell Insulating Oil Water- Soluble Acid Detector, Soluble Acid Analyzer hauv teb chaws GB/T7598-2008 Test Method for Water{11}}Soluble Acid nyob rau hauv-Service Transformer Oil. Nws yog dav siv nyob rau hauv daim phiaj fais fab, fais fab nroj tsuag, industrial & mining enterprises, transformer manufacturers thiab thib peb-tog roj xeem kuaj.
Dej-soluble acid uas tsim los ntawm cov roj oxidation yuav corrode hlau Cheebtsam ntawm cov khoom siv hluav taws xob thiab ua kom lub rwb thaiv tsev laus, uas yog ib qho yuav tsum tau kuaj cov khoom siv insulating roj. Nruab nrog microprocessor thiab 640 × 480 xim kov lub vijtsam, cov cuab yeej cia li ua tiav cov txheej txheem ntsuas tag nrho suav nrog cua sov, tswj qhov kub thiab txias, co, sawv, piv txwv, ob npaug - ntsuas qhov ntsuas xim colorimetric, cov ntaub ntawv khaws cia, luam ntawv, cov kav dej tu thiab rov qab reagent. Nws txhawb kev sim 1 txog 6 cov qauv roj ib zaug, nrog rau kev xaiv cov ntaub ntawv wireless xa mus rau lub khoos phis tawj sab saud. Cov khoom lag luam ua tau raws li qhov xav tau ntawm ob pawg neeg siv khoom: ib qho -ib qho kev yuav khoom rau cov tsev kho mob me me, thiab kev yuav khoom loj rau cov chaw tsim hluav taws xob, cov chaw faib khoom thiab cov haujlwm txhawb nqa engineering.
Khoom Parameter (Specification)
|
PH Measuring Range |
3.6-7.0, npog tag nrho lub sijhawm kuaj ntawm cov roj tshiab, cov roj tsis zoo thiab cov roj hnub nyoog |
|
Yam tsawg kawg pH zaub daws teeb meem |
0.1; Kev ntsuas qhov yuam kev tsawg dua lossis sib npaug ntawm ± 0.1pH, Kev Rov Ua Dua Tsawg dua lossis sib npaug li 0.1pH, ua raws li lub teb chaws tus qauv kev txwv tsis raug, cov ntawv xeem raug lees paub rau kev lees paub |
|
Qhov ntsuas kub tsis tu ncua |
± 2 degree, tus qauv rho tawm qhov kub thiab txias 75℃kom paub meej cov roj puv - dej rho tawm thiab ruaj khov rau qhov ntsuas qhov sib npaug rau cov qauv batch |
|
Txawb hom |
Reciprocating co, tsim cov qauv rho tawm los ntawm lub teb chaws tus qauv los txhim kho nag lossis daus efficiency ntawm dej -soluble acid |
|
Qauv Cells |
6 lub hlwb kuaj kev ywj pheej, txhawb nqa 1 ~ 6 cov qauv hauv ib pawg, txhawb kev ntsuas kev ua tau zoo los ntawm 6 zaug thiab txiav cov khoom siv ntxiv tus nqi. |
|
Tib neeg -Machine Interaction |
640 × 480 xim kov npo nrog tag nrho suav pom kev lag luam, kev cob qhia yooj yim rau cov neeg ua haujlwm hauv kev yuav khoom ntau |
|
Output Configuration |
Ua-hauv lub tshuab luam ntawv thermal; xaiv tau wireless kev sib txuas lus module los txuas PC sab sauv lub computer system |
|
Kev ua haujlwm ib puag ncig |
ambient kub 5℃~ 45 degree, txheeb ze av noo tsawg dua los yog sib npaug rau 85%; Fais fab mov AC220V ± 22V 50Hz ± 1Hz, haum rau kev ua haujlwm ntev - lub sijhawm ua haujlwm tsis tu ncua hauv cov chav kuaj huab cua |
Khoom feature
Tag nrho - tsis siv neeg kaw- kev ntsuas lub voj kom tshem tawm phau ntawv yuam kev:Kev koom ua ke ib zaug -chip microcomputer ntse tswj, ib qho - nyem pib ntawm cov txheej txheem xeem tiav; ob lub raj xa dej ywj pheej rau Bromocresol Purple thiab Bromocresol Green nrog kev hloov pauv tsis siv neeg, ua raws li lub teb chaws tus qauv kev ntsuas tshwj xeeb, ib tus neeg teb xov tooj tuaj yeem ua tiav txhua qhov kev xeem ntawm nws tus kheej.
Dej dawb tshuav nyiaj li cas calibration muaj nuj nqi:Kho kom haum rau qhov sib txawv ntawm cov dej distilled zoo nyob rau hauv lub chaw soj nstuam thoob plaws hauv lub tebchaws, ib qho -nias calibration sib sau ua ke cov qauv ntsuas kom tsis txhob muaj cov ntaub ntawv sib txawv thaum ntau chav nyob rau hauv ntau qhov chaw.
Modular ruaj qauv los txiav ntev - tus nqi tu:Separated peristaltic twj tso kua mis pipelines, ib tug puas hose yuav hloov ib tug zuj zus; tso tawm twj tso kua mis siab thaiv ntawm lub vaj huam sib luag tom qab tso tawm hose kev ntxhov siab thaum lub sij hawm tsis ua haujlwm, ncua kev pab cuam lub neej ntawm 3 zaug; muaj cov dej noo- pov thawj hlau plhaub adapts rau siab - cov av noo nyob ib puag ncig.
Loj - muaj peev xwm taug qab cov ntaub ntawv keeb kwm khaws cia:Khaws ntau tshaj 100 pawg ntawm cov ntaub ntawv xeem, cia li khaws cov xov tooj ntawm tes, pH tus nqi, qhov taw qhia hom thiab lub sijhawm ntsuas, txhawb nqa nplooj ntawv tig kev tshawb nrhiav, luam ntawv thiab cov ntaub ntawv tshem tawm, ua tau raws li kev tswj xyuas kev tswj hwm ntawm cov ntaub ntawv roj hluav taws xob.
Standard indicator solution matching scheme per national standard:Kev npaj cov mis ntawm Bromocresol Green thiab Bromocresol Purple txuas; dual sib cais lub teeb- pov thawj reagent slots ntawm cov khoom siv kom tsis txhob muaj cov qauv pov tseg los ntawm qhov tsis ncaj ncees lawm reagent loading, txo lab R&D thiab kev cob qhia tus nqi ntawm qhov ntsuas kev daws teeb meem.
Txhawb kev tswj hwm lub khoos phis tawj sab saud rau pab pawg multi-unit networking:Ntau tus neeg kuaj xyuas txuas rau PC ntawm qhov chaw nres nkoj serial lossis wireless teeb liab, teeb tsa lub sijhawm sib koom ua ke, qhov kub thiab txias thiab lub sijhawm sawv ntsug; cov ntaub ntawv xeem tuaj yeem muab xa tawm, xa tawm thiab luam tawm hauv cov khoom siv kom paub txog kev tswj xyuas cov ntawv tsis muaj ntawv digital, ua haujlwm sib txawv kom zoo dua rau cov phiaj xwm kev sib tw.
Universal consumables hla tag nrho cov khoom kab, txiav cov nqi khoom muag los ntawm 30% rau kev yuav khoom ntau:Peristaltic twj tso kua mis hoses, thermal ntawv thiab reagent fwj qhia unified specifications rau tag nrho cov units, tsis muaj cais npaj npaj yuav tsum tau rau txawv Hoobkas chaw; Kev txiav txim ntau tshaj 5 teeb los nrog cov khoom siv luv nqi, cov neeg xa khoom tuaj yeem tau txais lub tshuab & khoom siv sib xyaw ua ke.
Ib -stop tus nqi- ntxiv kev pabcuam rau kev txiav txim ntau:Pub dawb rau ntawm - qhov chaw ntsuas qhov chaw thiab chaw kuaj neeg ua haujlwm kev cob qhia rau kev xaj ntau dua 5 units; customized khau raj tshuaj ntsuam nrog neeg logo thiab khoom serial tooj muaj; Hoobkas muab kev sib tw template, Hoobkas calibration daim ntawv pov thawj thiab lub teb chaws tus qauv xeem tsab ntawv ceeb toom kom yooj yim rau kev sib tw thiab cov cuab yeej tshuaj xyuas txheej txheem.
National standardized tom qab -muag tu system:Kev sib koom ua ke 400 qhov kev pabcuam xovtooj 4000-177-185, cov neeg ua haujlwm nyob hauv lub tebchaws tau xa mus rau thoob tebchaws; Cov neeg siv khoom loj tuaj yeem kos npe rau daim ntawv cog lus kev saib xyuas txhua xyoo rau kev tshuaj xyuas ntawm qhov chaw tsis tu ncua, ntsuas ntsuas ntsuas ntsuas thiab hnav cov khoom hloov pauv, 24-teev hauv cheeb tsam hauv cheeb tsam ntawm qhov chaw tsis raug teb kom tsis txhob cuam tshuam ntawm kev sim roj ua haujlwm.
Kev nruj kev koom ua ke Hoobkas zoo tswj kom zoo ib yam batch kev ua tau zoo:Txhua tus neeg kuaj tau dhau 72- teev puv-load aging test nrog 6 lub hlwb ua haujlwm ntxiv rau tus kheej ntsuas ntsuas ua ntej xa khoom; tag nrho cov khoom xa tawm tuaj yeem tswj hwm qhov tseeb thiab ua haujlwm kom tshem tawm kev lees paub tsis sib haum xeeb hauv cov haujlwm engineering.
Khoom siv
1.Small power care teams, mini thib peb-tog sim roj test, me transformer repair factories thiab self-muaj power plants. Ib zaug xwb 6-Cell Insulating Oil Water-Soluble Acid Tester ua tau raws li cov kev xav tau ntawm cov roj insulating txhua hnub.
2.Provincial & municipal power grid corporations, loj thermal & hydropower nroj tsuag, metallurgical & tshuaj muaj qhauj, fais fab khoom distributors, general fais fab engineering cog lus thiab transformer manufacturers. Kev xa tawm loj paub txog kev sim synchronous thoob plaws ntau qhov chaw & chaw sim nrog cov qauv ntsuas kev sib koom ua ke thiab kev tswj hwm cov ntaub ntawv hauv nruab nrab.
Factory Delivery Accessories List
1 lub ntsiab tester,
6 pcs ntawm 250ml tshwj xeeb conical flasks,
Tag nrho cov khoom seem ntawm cov twj tso kua mis peristaltic,
Phau ntawv ua haujlwm puv puv,
Upper computer software installation pob,
Factory metrological calibration daim ntawv pov thawj,
National standard conformity test report,
1 yob ntawm thermal printing ntawv.
FAQ
Q: Koj puas yog cov chaw tsim khoom lossis lub tuam txhab lag luam?
A: Peb yog cov chaw tsim khoom ncaj qha tshwj xeeb hauv siab - cov khoom siv ntsuas hluav taws xob. Peb muaj peb tus kheej R & D pab neeg thiab cov chaw tsim khoom, uas tso cai rau peb muab lub Hoobkas - tus nqi ncaj qha thiab kev tswj xyuas nruj.
Q: Koj qhov warranty thiab tom qab - txoj cai muag khoom yog dab tsi?
A: Txhua chav tuaj nrog 12 lub hlis lav. Tom qab lub warranty tas sij hawm, peb muab kev pab cuam lub neej thiab cov kev pab them nqi kho mob.
Q: Koj puas txhawb kev sib tham lus Askiv?
A: Yog lawm, peb cov qauv qauv muaj cov keyboards Askiv, software, thiab cov neeg siv phau ntawv. Yog tias koj xav tau lwm hom lus, thov hu rau peb los kuaj xyuas qhov muaj rau kev kho.
Cim npe nrov: dej -soluble acid tester rau transformer roj, Tuam Tshoj dej-soluble acid tester rau transformer roj manufacturers, hoobkas