Khoom Taw Qhia
Lub MOEORW-WHF11+ Comprehensive Instrument Transformer Tester yog ib qho kev xeem cov cuab yeej siv rau P-chav kawm tam sim no transformers (CT) thiab voltage transformers (PT). Nws koom ua ke tag nrho cov txheej txheem kev sim ua haujlwm rau cov tshuab hloov pauv, suav nrog kev ntsuas tus yam ntxwv zoo, kev hloov pauv hloov pauv & kev txheeb xyuas polarity, demagnetization, 5% / 10% kev ua yuam kev nkhaus nkhaus, kev tshuaj xyuas theem ob, lub zog zaus AC tiv taus qhov ntsuas hluav taws xob thiab ntsuas qhov ntsuas thib ob.
Nruab nrog lub siab -txhais LCD zaub thiab tsim- hauv lub tshuab luam ntawv thermal mini, cov cuab yeej txhawb nqa ntawm -qhov chaw tiag - lub sijhawm luam ntawv. Nws khaws ib USB cov ntaub ntawv xa tawm interface los khaws tag nrho cov ntawv xeem rau kev soj ntsuam offline tom ntej thiab khaws cia. Featuring intuitive menu navigation thiab ib qho -nias test workflows, nws zoo heev simplifies teb cov txheej txheem rau lub hwj chim kuaj engineers.
Khoom Parameter
1. Txhawb cov khoom xeem
Tam sim no Transformer (CT) Test Functions
1.Magnetization (excitation) yam ntxwv nkhaus kuaj
2.Kev ntsuas qhov sib piv
3.Polarity kev txheeb xyuas
4.5% & 10% composite yuam kev nkhaus xam & ALF tsom xam
5.High tam sim no kev txhaj tshuaj
6.Integrated ceev tsis siv neeg kuaj
7.Power zaus AC withstand voltage test
8.Tsis siv neeg lub hauv caug-point voltage & tam sim no xam rau excitation curves
9.Qhov tseeb thib ob load peev xwm kuaj
10.Secondary winding DC kuj ntsuas
Voltage Transformer (PT) Test Functions
1.Excitation yam ntxwv xeem
2.Kev ntsuas qhov sib piv
3.Polarity kev txheeb xyuas
4.Power zaus AC withstand voltage test
5.Secondary winding DC kuj ntsuas
6.Automatic lub hauv caug- taw tes tus nqi xam
7.Qhov tseeb thib ob load peev xwm kuaj
2. Core Technical Indicators
|
Qeb |
Yam khoom |
Technical Index |
|
Fais fab mov |
Kev ua haujlwm input zog |
AC220V ± 10%, 50Hz |
|
Tso zis muaj peev xwm |
Main Voltage tso zis |
0 ~ 1200V, siab tshaj plaws muaj peev xwm 5kVA, tso zis tam sim no txwv 20A |
|
High Current Output |
0~600A |
|
|
Kev ntsuas qhov tseeb |
Excitation Voltage & Tam sim no |
Tsawg dua lossis sib npaug li 0.5% (0.2% × nyeem ntawv + 0.3% × tag nrho teev) |
|
Secondary Winding Resistance |
Kev ntsuas ntau: 0.1 ~ 300Ω Qhov tseeb: Tsawg dua lossis sib npaug rau 1.0% (0.4% × nyeem + 0.6% × tag nrho teev) |
|
|
Secondary Load tiag tiag |
Kev ntsuas ntau: 5 ~ 500VAAccuracy: Tsawg dua lossis sib npaug li 0.5% (0.2% × nyeem + 0.3% × tag nrho teev) ± 0.1VA |
|
|
Phase Angle Qhov txawv |
Qhov tseeb: Tsawg dua lossis sib npaug li 4 feeb ntawm arc; Kev daws teeb meem: 0.1 feeb ntawm arc |
|
|
CT Ratio Test |
Ntau yam: mus txog 50000A / 5A (10000A / 1A) Qhov tseeb: Tsawg dua lossis sib npaug li 0.5% (0.2% × nyeem ntawv + 0.3% × tag nrho teev) |
|
|
PT Ratio Test |
Ntau yam: txog 500kVaccuracy: Tsawg dua lossis sib npaug li 0.5% (0.2% × nyeem ntawv + 0.3% × tag nrho teev) |
|
|
Kev ua haujlwm ib puag ncig |
Ambient Kub |
-10℃~ 40 degree |
|
txheeb ze humidity |
Tsawg dua lossis sib npaug li 90% (tsis yog-condensing) |
|
|
Qhov siab |
Tsawg dua los yog sib npaug li 1000m saum toj no hiav txwv theem |
|
|
Lub cev Dimension |
Zuag qhia tag nrho |
450mm × 280mm × 340mm |
|
Net nyhav |
Tsawg dua los yog sib npaug li 28 kg |
Khoom feature
1.Txhua-hauv-ib qho kev sim ua ke
Ua kom tiav CT & PT kev xeem ua haujlwm tau koom ua ke rau hauv ib chav tsev, tshem tawm qhov xav tau rau ntau yam khoom siv sib cais. Nws suav nrog kev tshuaj xyuas niaj hnub, kev lees txais kev lees paub thiab kev kuaj xyuas tsis raug rau cov cuab yeej hloov pauv.
2.Intelligent tsis siv neeg kuaj workflow
Ua-hauv ib qho- nyem Fast Test hom tuaj yeem ua tiav qhov sib piv-polarity thiab excitation tests nyob rau hauv ib ntus yam tsis muaj rov txuas lossis tsis rov pib dua, txiav lub sijhawm xeem dhau 60%.
3.High -kev ntsuas qhov system
Txais siab - daws teeb meem sampling Circuit Court nrog nruj multi- theem kev ua yuam kev algorithm; voltage, tam sim no, piv txwv thiab theem lub kaum sab xis ntsuas txhua qhov ua tau raws li qib siab - cov qauv ntsuas hluav taws xob, txhawb nqa calibration traceability.
4.Ntawm -cov ntaub ntawv chaw kaw & xa tawm cov kev daws teeb meem
Nruab nrog embedded thermal tshuab luam ntawv rau instant qhia luam ntawv; USB flash disk cov ntaub ntawv export muaj nuj nqi txhawb nqa batch cia ntawm magnetization curves, yuam kev nkhaus thiab tag nrho cov ntaub ntawv xeem rau lub computer offline xyuas.
5.Visualized LCD sib tham sib ua haujlwm
Loj xim LCD kov tswj vaj huam sib luag nrog categorized CT / PT ywj siab cov ntawv qhia zaub mov tseem ceeb, graphical wiring diagrams displayed on every test interface to reduce wiring errors.
6.Multi- txheej kev tiv thaiv kev nyab xeeb tsim
Integrated overvoltage, overcurrent, to tam sim no thiab flashover tiv thaiv circuits. Tus tester txiav txiav tawm cov zis thiab rov qab mus rau xoom ib zaug kuaj pom muaj qhov txawv txav los tiv thaiv ob qho khoom siv thiab cov neeg ua haujlwm.
7. Tsis siv neeg suav ntawm cov yam ntxwv tseem ceeb ntsuas
Independently xam excitation lub hauv caug- taw tes tsis, 5% / 10% yuam kev nkhaus thiab tso cai rau theem nrab load, txiav txim siab CT kev tsim nyog rau kev tiv thaiv daim ntawv thov yam tsis muaj phau ntawv muab xam.
8.Compact portable qauv
Optimized lub teeb hnyav txee tsim nrog ua - nyob rau hauv lub tshuab luam ntawv thiab lub hwj chim Circuit Court, yooj yim rau kev thauj mus los rau substation, fais fab nroj tsuag thiab lwm qhov chaw kuaj sab nraum zoov.
Khoom siv
Fais fab Grid Operation & Maintenance
- Kev tiv thaiv niaj hnub ntawm CT / PT hauv nroog thiab nyob deb nroog substations
- Kev kuaj xyuas tsis raug ntawm saturated, puas los yog miswired ntsuas transformers
- Secondary circuit load, tiv thaiv thiab polarity pov thawj thaum lub sij hawm soj ntsuam txhua hnub
Fais fab Engineering txais
- Kev xeem xa mus rau kev tsim kho tshiab, rov tsim kho dua tshiab thiab nthuav dav cov chaw faib hluav taws xob
- Kev tshuaj xyuas tag nrho ntawm CT / PT ua ntej daim phiaj ua haujlwm
- 5% / 10% yuam kev nkhaus pov thawj rau kev tiv thaiv-chav kawm tam sim no transformers
Cov Khoom Siv Hluav Taws Xob Cov Khoom Siv Hluav Taws Xob
- Factory offline tshuaj xyuas cov khoom tiav CT & PT
- Batch excitation yam ntxwv thiab kev hloov pauv piv rau cov kab ntau lawm
- Cov khoom lag luam ntawv pov thawj kuaj thiab cov ntaub ntawv tshaj tawm tsim tawm
Thib peb-Tag Nrho Lub Tsev Ntsuas Hluav Taws Xob
- Standardized sampling tshuaj xyuas rau cov khoom siv fais fab kev sib tw
- Independent calibration thiab kev ntsuas kev ua tau zoo ntawm cov cuab yeej transformers
- Archivable luam tawm cov ntawv xeem rau cov ntaub ntawv lees paub
Industrial Enterprise Fais fab Distribution Rooms
- Kev ntsuam xyuas kev nyab xeeb tsis tu ncua ntawm siab -voltage transformers nyob rau hauv lub Hoobkas fais fab mov systems
- Kev daws teeb meem ntawm kev ntsuas qhov sib txawv tshwm sim los ntawm CT core saturation lossis ntau dhau ntawm cov khoom nruab nrab
Daim ntawv teev cov Standard Accessories suav nrog
Standard Delivery Accessories
1.Main MOEORW-WHF11+ tester host ×1
2. Fais fab cable (AC220V) × 1
3.Grounding hlau × 1
4.Tag nrho cov siab -voltage test txuas xov hlau (rau excitation, withstand voltage, ratio test)
5.Secondary low-tsis kam kuaj cov xov hlau × 1 pawg
6.Thermal tshuab luam ntawv yob × 5
7.User lag luam phau ntawv (English version) × 1
8.USB flash disk (rau cov ntaub ntawv xa tawm) × 1
9.Portable cuab yeej lub hnab rau kev xeem xov hlau × 1
Optional Extended Modules
1.External siab -tam sim no booster module (max 1000A thawj txhaj tshuaj)
2.Wireless cov ntaub ntawv kis tau tus mob module (tej thaj chaw deb tiag-lub sij hawm cov ntaub ntawv upload)
3.Industrial ntsiav tshuaj davhlau ya nyob twg (offline cov ntaub ntawv tsom xam software ua ntej-ntsia)
4.Extended tshuab luam ntawv daim ntawv cia lub thawv
5.Shockproof portable thauj cov ntaub ntawv rau thaj tsam ntev - kev thauj mus los deb
FAQ
Q1: Puas tuaj yeem hloov kho kev sim ua haujlwm raws li peb qhov kev xav tau?
A: Yog, peb txhawb kev tsim kho kev ua haujlwm rau kev txiav txim ntau. Koj tuaj yeem xa koj cov qauv kev xeem tshwj xeeb, cov ntaub ntawv tshaj tawm cov ntaub ntawv lossis cov kev xav tau cuam tshuam rau peb pab pawg muag khoom, thiab peb lub tuam txhab R & D yuav muab cov kev daws teeb meem customized thiab kev xa khoom xa tuaj.
Q2: Lub sijhawm xa khoom rau ntau qhov kev txiav txim yog dab tsi?
A: Cov khoom ntim khoom tuaj yeem xa tuaj hauv 3-5 hnub ua haujlwm. Customized modified khoom xav tau 15-30 hnub ua haujlwm nyob ntawm qhov kev hloov kho. Peb tus thawj tswj hwm kev muag khoom yuav lees paub lub sijhawm teem sijhawm nrog koj raws li kev txiav txim pom zoo.
Q3: Koj puas muab rau ntawm - qhov kev pabcuam kev cob qhia?
A: Peb muab kev cob qhia ua haujlwm online dawb rau txhua tus neeg siv khoom. Rau cov neeg yuav khoom loj, peb tuaj yeem npaj cov kws tshaj lij engineers los muab rau ntawm - kev cob qhia chaw ntawm koj qhov chaw, suav nrog kev ua haujlwm ntawm cov khoom siv, kev txheeb xyuas cov ntaub ntawv thiab kev cob qhia kev saib xyuas yooj yim.
Q4: Cov khoom puas tuaj yeem dhau lub teb chaws metrology lub koom haum calibration?
A: Tag nrho peb cov cuab yeej ua tau raws li cov qauv ntsuas hluav taws xob hauv lub tebchaws thiab tuaj yeem ua tau zoo dhau qhov thib peb - tog metrology calibration. Peb tuaj yeem muab daim ntawv pov thawj calibration template rau koj siv ua ntej yuav khoom.
Cim npe nrov: Tuam Tshoj Comprehensive ntsuas transformer tester, Tuam Tshoj kev ntsuas ntsuas transformer manufacturers, hoobkas