DC Ground Fault Finder

Xa kev nug
DC Ground Fault Finder
Paub meej
MEZN-WZA40 Portable DC Ground Fault Locator Tau tshaj 24V-280V DC systems Nyhav: 1.7kg + 1.5kg Touchscreen ua haujlwm nrog FFT thev naus laus zis siab cuam tshuam tsis muaj hluav taws xob kaw yuav tsum tau siv 10-teev roj teeb lub neej Ua kom pom tseeb ntawm ntau yam hauv av thiab kev ua txhaum cai.
Kev faib tawm yam khoom
Roj teeb Tester
Share to
Hauj lwm lawm

Portable DC Ground Fault Locator

 

Khoom Taw Qhia

 

Lub portable DC hauv av fault locator siv lub siab -precision tam sim no clamp meter los xyuas thiab txheeb xyuas qhov txhaum los ntawm kev ntsuas qhov sib txawv ntawm DC tam sim no nyob rau hauv lub faulty circuit. Los ntawm kev sib koom ua ke ceev FFT thev naus laus zis rau hauv DC qhov tsis raug cov cuab yeej tshawb nrhiav, nws tuaj yeem txheeb xyuas ntau yam kev cuam tshuam ntawm rwb thaiv tsev, DC cross-kev ua txhaum cai, thiab AC hla-kev ua txhaum cai hla txhua theem voltage (24V, 48V, 110V, 220V) hauv DC systems. Cov cuab yeej no muaj qhov ntsuas pom tau zoo, muaj zog tiv thaiv- muaj peev xwm cuam tshuam, qhov loj me, lub teeb yuag, thiab cov neeg siv- ua haujlwm zoo. Thaum nrhiav DC system hauv av faults, nws yuav tsum tsis muaj hluav taws xob cuam tshuam thiab ua kom meej meej grounding point localization. Cov cuab yeej ntsuas DC system grounding resistance values ​​thiab txiav txim siab grounding direction, muab ib tug txhim khu kev qha, siab -cov cuab yeej nrhiav kom tau tseeb rau nrhiav thiab pinpointing av faults nyob rau hauv lub hwj chim DC systems.

Raws li lub tshuab hluav taws xob xav tau kev ruaj ntseg ntxiv rau kev ua haujlwm, qhov kev xav tau rau kev tshawb nrhiav DC siab heev yuav loj tuaj. Yog li ntawd, kev ntsuas siab thiab kev ntsuas hluav taws xob rwb thaiv tsev yuav dhau los ua qhov yuav tsum tau ua rau tiam tom ntej ntawm portable DC av txhaum locators hauv lub tshuab hluav taws xob.

Tus tshiab portable DC av txhaum locator, raws li lub hauv paus ntsiab lus ntawm DC tam sim no sib txawv nrhiav kom tau, koom nrog ceev FFT transformation technology. Los ntawm kev soj ntsuam cov ncauj lus kom ntxaws ntawm qhov amplitude - tus yam ntxwv zaus ntawm qhov ntsuas qhov ntsuas, nws ntsuas qhov tsis sib haum xeeb xav tau ntawm kev nyab xeeb thiab rhiab heev hauv DC hauv av txhaum qhov chaw. Qhov kev nce qib no txhawb nqa DC hauv av txhaum kev tshawb nrhiav thev naus laus zis mus rau qib tshiab, muab cov ntawv thov dav dav.

 

Khoom Parameter (Specification)

 

2.1 Analyzer

Kev khiav hauj lwm voltage

Ncaj qha los ntawm busbar (kev ua haujlwm voltage; 24V txog 280V)

Voltage Measurement Range

0-300V

Kev ntsuas qhov ntsuas qhov tseeb

0.5%

Choj ua haujlwm hom

Tus choj tsis sib haum

Kev Tshawb Fawb Tshaj Tawm Tshaj Tawm Lub Zog

<0.01W

Maximum Signal Power Supply Tam sim no

Tsawg dua los yog sib npaug rau 800μA

Teeb liab zaus

Tsawg dua lossis sib npaug li 0.5Hz

Qhov System Ground Voltage Fluctuation

Tsawg dua lossis sib npaug li 10% Un

Busbar Av Resistance Detection Range

0-999.9 kΩ

Choj ua haujlwm hom

Tus choj tsis sib haum

Busbar Av Resistance Ntsuas Qhov tseeb

Tsawg dua lossis sib npaug li 5%

Resistance ntsuas kev daws teeb meem

0.01 kΩ

AC interference voltage ntsuas ntau yam

0-250 V

AC cuam tshuam voltage ntsuas qhov tseeb

Tsawg dua lossis sib npaug li 2%

Roj teeb grounding ntsuas yuam kev (2V)

Tsawg dua los yog sib npaug rau 3 cell

Kev siv fais fab

Tsawg dua 10 W

Qhov Loj (L × W × H)

200 × 145 × 46 hli (mm)

Qhov hnyav

1.7kg ib

Ua haujlwm kub

-10℃rau +50 degree

2.2 Locator

Kev khiav hauj lwm voltage

3.7V (Lithium roj teeb ua haujlwm, 3.2V-4.2V ntau yam, zoo ib yam li cov xov tooj ntawm tes)

Hom kev ua haujlwm

Touchscreen

Ceg av Resistance Detection Range

0-999kΩ (Lub Hoobkas pib; 300kΩ)

Ceg av Resistance Measurement Accuracy

0-150kΩ (tsawg dua lossis sib npaug 10% ± 2kΩ), 150-999kΩ qhia txog qhov tseem ceeb

Av Resistance Measurement Resolution

0.1kΩ

Leakage Current Detection Sensitivity

Tsawg dua lossis sib npaug li 0.1μA

Kev ntsuas qhov tseeb

100%

Tswb hom

Graphic, cov ntaub ntawv, grounding direction

Suab ceeb toom

Grounding, hla -kev sib txuas, ntsuas qhov tseem ceeb, kev coj ua txhaum, thiab lwm yam.

Waveform zaub

Standard sine waveform (zoo ib yam li oscilloscope)

Clamp paub

Tsis siv neeg txheeb xyuas qhov loj / me clamps thiab qhib / kaw lub xeev

Lub sijhawm ua haujlwm tsis tu ncua

>10 teev

Qhov Loj (L × W × H)

180 × 100 × 40 hli (mm)

Qhov hnyav

1.5 kg ib

Ua haujlwm kub

-10℃rau +50 degree

Fais fab mov

Lithium roj teeb (3.7V, 4000mAh rechargeable)

 

Khoom feature thiab daim ntawv thov

 

1. Qhov ntsuas no muaj lub teeb liab transmitter (analyzer) thiab receiver (locator). Lub analyzer rub lub zog ncaj qha los ntawm lub busbar, tshem tawm qhov xav tau rau sab nraud AC lossis roj teeb lub zog, ua haujlwm yooj yim dua;

2. Nws daws txhua qhov txhaum hauv av, suav nrog:

- Tsis zoo rwb thaiv tsev ua rau phantom grounding

- Siab -tsis kam grounding

- Ntau - taw tes hauv av

- Ib qho - taw tes hauv av

- Tsawg- tsis kam grounding

- Direct grounding

- Sib tov - kab hauv av

- Loop grounding

- Capacitive grounding

- AC leakage grounding

- Transistor cais grounding

3. Ua kom tiav DC system grounding faults. Tsis muaj kev cuam tshuam los ntawm kev faib tawm loj hauv thaj teb, nws raug txheeb xyuas thiab nrhiav qhov tsis raug hauv thaj chaw me tshaj plaws.

4. Qhia meej meej txog cov kev taw qhia ntawm cov teeb liab hauv av tam sim no, ua kom paub ceev ceev ntawm qhov yuam kev;

5. Muab lub suab tshaj tawm hais txog qhov xwm txheej hauv av thiab kev taw qhia;

6. Precisely pom qhov loj thiab theem ntawm kab xau tam sim no, sai thiab raug qhov chaw qhov txhaum raws li kev hloov pauv tam sim no hauv qhov dej ntws tam sim no thiab theem ua ntej thiab tom qab qhov chaw txhaum;

7. Ib qho DC grounding analyzer ua haujlwm rau txhua lub tshuab DC hauv qab 300V, tsis muaj qhov tshwj xeeb ntxiv rau DC voltage;

7. Tag nrho touchscreen ntse tsim rau txhim kho usability; tsis muaj khawm tswj yuav tsum tau. Qhov siab tshaj qhov teeb meem tam sim no<800μA with built-in current limiting protection, ensuring no impact on relay protection, automation devices, or operating circuits for safe operation;

8. Ripple tsom xam thiab digital oscilloscope functionality: Siv spectrum tsom xam kom tshem tawm ntau yam cuam tshuam cov teeb liab thiab saib waveform cov ntaub ntawv ntawm nrhiav pom thiab circuits;

9. Kev txawj ntse tam sim no clamp tau pom qhov qhib / kaw, sib xws nrog ob lub puab tsaig loj thiab me;

10. Adaptable rau hauv av faults tshwm sim los ntawm AC / DC cross-conduction, nplhaib network mov grounding, diode- cais mov grounding, thiab siab - resistance grounding;

11. daws tib yam -ncej / txawv-ncej DC cross-kev ua txhaum cai thiab txheeb xyuas cov ceg tsis raug;

12. Txhawb chaw nres tsheb fais fab khoom siv nrog ntau yam specifications thiab av capacitance, ntsuas busbar capacitance qhov tseem ceeb;

13. Ceev nrooj nrhiav cov teeb meem hauv av yam tsis muaj kev teeb tsa, hluav taws xob tawm, kev sib txuas ntawm cov xov hlau, lossis kev ntsuas hluav taws xob;

14. Tus neeg siv- tus phooj ywg ntse kov interface rau kev ua haujlwm yooj yim, ntim hwm kom yooj yim txav mus los.

 

Kev tsim tawm cov ntsiab lus

 

MEZN-WZA40 Portable DC Ground Fault Locator yog tsim los rau kev daws teeb meem DC system faults thoob plaws ntau yam xwm txheej, nrog rau cov ntawv thov tseem ceeb suav nrog:

- DC kev ua haujlwm fais fab hauv cov chaw tsim hluav taws xob thiab chaw nres tsheb, daws teeb meem busbar thiab ceg hauv av / hla- teeb meem txhaum cai;

- Chav tsev faib khoom lag luam thiab DC fais fab vaj huam sib luag, tshawb xyuas qhov cuam tshuam ntawm rwb thaiv tsev thiab AC cross - tua hluav taws ntawm 24V-280V voltage;

DC fais fab mov systems hauv kev tsheb ciav hlau thiab kev sib txuas lus hauv paus chaw nres tsheb, ceev nrooj nrhiav qhov nyuaj hauv av xws li siab -kuj, ntau- taw tes, lossis sib xyaw- kab faults;

Ntau lub chaw nres tsheb fais fab khoom siv thiab roj teeb- lub tshuab siv hluav taws xob, ua kom haum rau qhov sib txawv hauv av qhov tshwj xeeb kom ua tau qhov tsis raug tsis muaj zog cuam tshuam;

Lub zog ua haujlwm thiab kev saib xyuas qhov chaw, soj ntsuam kev nyab xeeb hauv av hauv DC circuits ntsig txog kev tiv thaiv relay thiab cov khoom siv automation (tsis cuam tshuam cov khoom siv ua haujlwm).

 

Lub Tuam Txhab Txuj Ci

 

 

 

FAQ

1) Puas yog MEZN-WZA40 Portable DC Ground Fault Locator yuav tsum tau kaw lub hwj chim thaum ua haujlwm?

Teb: Tsis yog. Cov cuab yeej no muaj cov qauv tsim uas tshem tawm qhov xav tau rau kev teeb tsa, kev kaw lub hwj chim, tshem tawm cov kab hluav taws xob, kev sib txuas ntawm cov xaim, lossis kev ntsuas hluav taws xob. Nws ua rau qhov chaw ua txhaum ncaj qha thaum lub DC system tseem ua haujlwm, tiv thaiv hluav taws xob hluav taws xob uas tuaj yeem cuam tshuam kev ua haujlwm ntawm lub zog ib txwm muaj.

2) MEZN-WZA40 Portable DC Ground Fault Locator ua li cas thiaj li ua tiav qhov txhaum qhov chaw hauv cheeb tsam?

Teb: Lub ntsuas hluav taws xob ua haujlwm los ntawm kev sib koom ua ke ntawm tus ntsuas ntsuas (lub teeb liab transmitter) thiab qhov chaw (receiver). Lub ntsuas ntsuas ntsuas qhov ntsuas hluav taws xob thaiv hluav taws xob, txheeb xyuas qhov chaw hauv av lossis hla - tej yam kev mob txhaum cai, thiab tsim kom muaj kev sib txuas wireless nrog lub chaw teeb tsa. Tus neeg nrhiav chaw siv lub cuab yeej ntse tam sim no txhawm rau tuav txhua ceg hauv Circuit Court (ib txhij clamping ob qho tib si zoo thiab qhov tsis zoo thaum tseem nyob ruaj khov). Nias "Start Test" qhia txog ceg av tiv thaiv, capacitance, thiab kev taw qhia hauv av. Txav qhov tam sim no clamp raws lub faulty ceg Circuit Court. Yog hais tias qhov ntsuas tsis kam dheev nce ntxiv (qhia tias txo qhov cuam tshuam tam sim no), thaj chaw tam sim ntawd ua ntej qhov ntsuas ntsuas no yog qhov chaw txhaum. Lub ntsuas ntsuas ntxiv pab nrhiav qhov txhaum los ntawm lub suab prompts, graphical indicators, thiab cov ntaub ntawv ceeb toom.

3) Puas yog MEZN-WZA40 Portable DC Ground Fault Locator cuam tshuam rau kev tiv thaiv relay lossis automation li hauv cov tshuab hluav taws xob?

Teb: Tsis muaj kev cuam tshuam. Lub ntsuas hluav taws xob qhov hluav taws xob muaj qhov siab tshaj plaws tam sim no Tsawg dua lossis sib npaug rau 800μA nrog ua - hauv kev tiv thaiv tam sim no. Lub zog siab tshaj plaws ntawm kev kuaj pom yog<0.01W. It will not interfere with relay protection, automation devices, or operating circuits during operation, ensuring safe and reliable use.

 

Cim npe nrov: dc av txhaum finder, Tuam Tshoj dc av txhaum finder manufacturers, hoobkas

Xa kev nug